Siemens 6AG2531-7KF00-4AB0

SIPLUS S7-1500 AI 8xU/I/RTD/TC TX rail based on 6ES7531-7KF00-0AB0 with conformal coating, -40…+70 °C

MPN
6AG2531-7KF00-4AB0
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Siemens parts? We buy surplus →

What is the Siemens 6AG2531-7KF00-4AB0?

SIPLUS S7-1500 AI 8xU/I/RTD/TC TX rail based on 6ES7531-7KF00-0AB0 with conformal coating, -40…+70 °C, OT4 with ST1/2 (+85 °C for 10 minutes), analog input module 16-bit resolution, accuracy 0.3%, 8 channels in groups of 8, 4 channels for RTD measurement, common mode voltage 10 V; diagnostics; hardware interrupts including infeed element, shielding bracket and shield terminal

Specifications

General information

Product type designationAI 8xU/I/RTD/TC ST
Firmware version — FW update possibleYes
based on6ES7531-7KF00-0AB0
Product function — I&M dataYes; I&M0 to I&M3
Product function — Isochronous modeNo
Product function — Prioritized startupNo
Product function — Measuring range scalableNo
Product function — Scalable measured valuesNo
Product function — Adjustment of measuring rangeNo
Engineering with — STEP 7 TIA Portal configurable/integrated from versionsee entry ID: 109746275
Operating mode — OversamplingNo
Operating mode — MSIYes

CiR - Configuration in RUN

Reparameterization possible in RUNYes
Calibration possible in RUNYes

Supply voltage

Rated value (DC)24 V
permissible range, lower limit (DC)19.2 V
permissible range, upper limit (DC)28.8 V
Reverse polarity protectionYes

Input current

Current consumption, max.255 mA; with 19.2 V supply

Encoder supply

24 V encoder supply — Short-circuit protectionYes
24 V encoder supply — Output current, max.20 mA; Max. 47 mA per channel for a duration < 10 s

Power

Power consumption from the backplane bus0.7 W

Power loss

Power loss, typ.2.7 W

Analog inputs

Number of analog inputs8; > +60 °C max. 2x ±20 mA or 4x ±10 V or 4x RTD permissible
Number of analog inputs — For current measurement8
Number of analog inputs — For voltage measurement8
Number of analog inputs — For resistance/resistance thermometer measurement4
Number of analog inputs — For thermocouple measurement8
permissible input voltage for voltage input (destruction limit), max.28.8 V
permissible input current for current input (destruction limit), max.40 mA
Constant measurement current for resistance-type transmitter, typ.150 Ohm, 300 Ohm, 600 Ohm, Pt100, Pt200, Ni100: 1.25 mA; 6 000 Ohm, Pt500, Pt1000, Ni1000, LG-Ni1000: 0.625 mA; PTC: 0.472 mA
Technical unit for temperature measurement adjustableYes; °C/°F/K
Input ranges (rated values), voltages — 0 to +5 VNo
Input ranges (rated values), voltages — 0 to +10 VNo
Input ranges (rated values), voltages — 1 V to 5 VYes
Input ranges (rated values), voltages — 1 V to 5 V — Input resistance (1 V to 5 V)100 kΩ
Input ranges (rated values), voltages — 1 V to +1 VYes
Input ranges (rated values), voltages — 1 V to +1 V — Input resistance (-1 V to +1 V)10 MΩ
Input ranges (rated values), voltages — 10 V to +10 VYes
Input ranges (rated values), voltages — 10 V to +10 V — Input resistance (-10 V to +10 V)100 kΩ
Input ranges (rated values), voltages — 2.5 V to +2.5 VYes
Input ranges (rated values), voltages — 2.5 V to +2.5 V — Input resistance (-2.5 V to +2.5 V)10 MΩ
Input ranges (rated values), voltages — 25 mV to +25 mVNo
Input ranges (rated values), voltages — 250 mV to +250 mVYes
Input ranges (rated values), voltages — 250 mV to +250 mV — Input resistance (-250 mV to +250 mV)10 MΩ
Input ranges (rated values), voltages — 5 V to +5 VYes
Input ranges (rated values), voltages — 5 V to +5 V — Input resistance (-5 V to +5 V)100 kΩ
Input ranges (rated values), voltages — 50 mV to +50 mVYes
Input ranges (rated values), voltages — 50 mV to +50 mV — Input resistance (-50 mV to +50 mV)10 MΩ
Input ranges (rated values), voltages — 500 mV to +500 mVYes
Input ranges (rated values), voltages — 500 mV to +500 mV — Input resistance (-500 mV to +500 mV)10 MΩ
Input ranges (rated values), voltages — 80 mV to +80 mVYes
Input ranges (rated values), voltages — 80 mV to +80 mV — Input resistance (-80 mV to +80 mV)10 MΩ
Input ranges (rated values), currents — 0 to 20 mAYes
Input ranges (rated values), currents — 0 to 20 mA — Input resistance (0 to 20 mA)25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC
Input ranges (rated values), currents — 20 mA to +20 mAYes
Input ranges (rated values), currents — 20 mA to +20 mA — Input resistance (-20 mA to +20 mA)25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC
Input ranges (rated values), currents — 4 mA to 20 mAYes
Input ranges (rated values), currents — 4 mA to 20 mA — Input resistance (4 mA to 20 mA)25 Ω; Plus approx. 42 ohms for overvoltage protection by PTC
Input ranges (rated values), thermocouples — type BYes
Input ranges (rated values), thermocouples — type B — Input resistance (Type B)10 MΩ
Input ranges (rated values), thermocouples — type CNo
Input ranges (rated values), thermocouples — Type EYes
Input ranges (rated values), thermocouples — Type E — Input resistance (Type E)10 MΩ
Input ranges (rated values), thermocouples — Type JYes
Input ranges (rated values), thermocouples — Type J — Input resistance (type J)10 MΩ
Input ranges (rated values), thermocouples — Type KYes
Input ranges (rated values), thermocouples — Type K — Input resistance (Type K)10 MΩ
Input ranges (rated values), thermocouples — Type LNo
Input ranges (rated values), thermocouples — Type NYes
Input ranges (rated values), thermocouples — Type N — Input resistance (Type N)10 MΩ
Input ranges (rated values), thermocouples — Type RYes
Input ranges (rated values), thermocouples — Type R — Input resistance (Type R)10 MΩ
Input ranges (rated values), thermocouples — Type SYes
Input ranges (rated values), thermocouples — Type S — Input resistance (Type S)10 MΩ
Input ranges (rated values), thermocouples — Type TYes
Input ranges (rated values), thermocouples — Type T — Input resistance (Type T)10 MΩ
Input ranges (rated values), thermocouples — Type TXK/TXK(L) to GOSTNo
Input ranges (rated values), resistance thermometer — Cu 10No
Input ranges (rated values), resistance thermometer — Cu 10 according to GOSTNo
Input ranges (rated values), resistance thermometer — Cu 50No
Input ranges (rated values), resistance thermometer — Cu 50 according to GOSTNo
Input ranges (rated values), resistance thermometer — Cu 100No
Input ranges (rated values), resistance thermometer — Cu 100 according to GOSTNo
Input ranges (rated values), resistance thermometer — Ni 10No
Input ranges (rated values), resistance thermometer — Ni 10 according to GOSTNo
Input ranges (rated values), resistance thermometer — Ni 100Yes; Standard/climate
Input ranges (rated values), resistance thermometer — Ni 100 — Input resistance (Ni 100)10 MΩ
Input ranges (rated values), resistance thermometer — Ni 100 according to GOSTNo
Input ranges (rated values), resistance thermometer — Ni 1000Yes; Standard/climate
Input ranges (rated values), resistance thermometer — Ni 1000 — Input resistance (Ni 1000)10 MΩ
Input ranges (rated values), resistance thermometer — Ni 1000 according to GOSTNo
Input ranges (rated values), resistance thermometer — LG-Ni 1000Yes; Standard/climate
Input ranges (rated values), resistance thermometer — LG-Ni 1000 — Input resistance (LG-Ni 1000)10 MΩ
Input ranges (rated values), resistance thermometer — Ni 120No
Input ranges (rated values), resistance thermometer — Ni 120 according to GOSTNo
Input ranges (rated values), resistance thermometer — Ni 200 according to GOSTNo
Input ranges (rated values), resistance thermometer — Ni 500No
Input ranges (rated values), resistance thermometer — Ni 500 according to GOSTNo
Input ranges (rated values), resistance thermometer — Pt 10No
Input ranges (rated values), resistance thermometer — Pt 10 according to GOSTNo
Input ranges (rated values), resistance thermometer — Pt 50No
Input ranges (rated values), resistance thermometer — Pt 50 according to GOSTNo
Input ranges (rated values), resistance thermometer — Pt 100Yes; Standard/climate
Input ranges (rated values), resistance thermometer — Pt 100 — Input resistance (Pt 100)10 MΩ
Input ranges (rated values), resistance thermometer — Pt 100 according to GOSTNo
Input ranges (rated values), resistance thermometer — Pt 1000Yes; Standard/climate
Input ranges (rated values), resistance thermometer — Pt 1000 — Input resistance (Pt 1000)10 MΩ
Input ranges (rated values), resistance thermometer — Pt 1000 according to GOSTNo
Input ranges (rated values), resistance thermometer — Pt 200Yes; Standard/climate
Input ranges (rated values), resistance thermometer — Pt 200 — Input resistance (Pt 200)10 MΩ
Input ranges (rated values), resistance thermometer — Pt 200 according to GOSTNo
Input ranges (rated values), resistance thermometer — Pt 500Yes; Standard/climate
Input ranges (rated values), resistance thermometer — Pt 500 — Input resistance (Pt 500)10 MΩ
Input ranges (rated values), resistance thermometer — Pt 500 according to GOSTNo
Input ranges (rated values), resistors — 0 to 150 ohmsYes
Input ranges (rated values), resistors — 0 to 150 ohms — Input resistance (0 to 150 ohms)10 MΩ
Input ranges (rated values), resistors — 0 to 300 ohmsYes
Input ranges (rated values), resistors — 0 to 300 ohms — Input resistance (0 to 300 ohms)10 MΩ
Input ranges (rated values), resistors — 0 to 600 ohmsYes
Input ranges (rated values), resistors — 0 to 600 ohms — Input resistance (0 to 600 ohms)10 MΩ
Input ranges (rated values), resistors — 0 to 3000 ohmsNo
Input ranges (rated values), resistors — 0 to 6000 ohmsYes
Input ranges (rated values), resistors — 0 to 6000 ohms — Input resistance (0 to 6000 ohms)10 MΩ
Input ranges (rated values), resistors — PTCYes
Input ranges (rated values), resistors — PTC — Input resistance (PTC)10 MΩ
Thermocouple (TC) — Temperature compensation — ParameterizableYes
Thermocouple (TC) — Temperature compensation — internal temperature compensationYes
Thermocouple (TC) — Temperature compensation — external temperature compensation via RTDYes
Thermocouple (TC) — Temperature compensation — Compensation for 0 °C reference point temperatureYes; fixed value can be set
Thermocouple (TC) — Temperature compensation — Reference channel of the moduleYes
Cable length — shielded, max.800 m; for U/I, 200 m for R/RTD, 50 m for TC

Analog value generation for the inputs

Integration and conversion time/resolution per channel — Resolution with overrange (bit including sign), max.16 bit
Integration and conversion time/resolution per channel — Integration time, parameterizableYes
Integration and conversion time/resolution per channel — Integration time (ms)2,5 / 16,67 / 20 / 100 ms
Integration and conversion time/resolution per channel — Basic conversion time, including integration time (ms)9 / 23 / 27 / 107 ms
Integration and conversion time/resolution per channel — Basic conversion time, including integration time (ms) — additional conversion time for wire-break monitoring9 ms (to be considered in R/RTD/TC measurement)
Integration and conversion time/resolution per channel — Basic conversion time, including integration time (ms) — additional conversion time for resistance measurement150 ohm, 300 ohm, 600 ohm, Pt100, Pt200, Ni100: 2 ms, 6000 ohm, Pt500, Pt1000, Ni1000, LG-Ni1000, PTC: 4 ms
Integration and conversion time/resolution per channel — Interference voltage suppression for interference frequency f1 in Hz400 / 60 / 50 / 10 Hz
Integration and conversion time/resolution per channel — Time for offset calibration (per module)Basic conversion time of the slowest channel
Smoothing of measured values — ParameterizableYes
Smoothing of measured values — Step: NoneYes
Smoothing of measured values — Step: lowYes
Smoothing of measured values — Step: MediumYes
Smoothing of measured values — Step: HighYes

Encoder

Connection of signal encoders — for voltage measurementYes
Connection of signal encoders — for current measurement as 2-wire transducerYes
Connection of signal encoders — for current measurement as 2-wire transducer — Burden of 2-wire transmitter, max.820 Ω
Connection of signal encoders — for current measurement as 4-wire transducerYes
Connection of signal encoders — for resistance measurement with two-wire connectionYes; Only for PTC
Connection of signal encoders — for resistance measurement with three-wire connectionYes; All measuring ranges except PTC; internal compensation of the cable resistances
Connection of signal encoders — for resistance measurement with four-wire connectionYes; All measuring ranges except PTC

Errors/accuracies

Linearity error (relative to input range), (+/-)0.02 %
Temperature error (relative to input range), (+/-)0.005 %/K; With TC type T 0.02 ± % / K
Crosstalk between the inputs, max.-80 dB
Repeat accuracy in steady state at 25 °C (relative to input range), (+/-)0.02 %
Temperature error of internal compensation±6 °C
Operational error limit in overall temperature range — Voltage, relative to input range, (+/-)0.4 %
Operational error limit in overall temperature range — Current, relative to input range, (+/-)0.4 %
Operational error limit in overall temperature range — Resistance, relative to input range, (+/-)0.4 %
Operational error limit in overall temperature range — Resistance thermometer, relative to input range, (+/-)Ptxxx standard: ±1.5 K, Ptxxx climate: ±0.5 K, Nixxx standard: ±0.5 K, Nixxx climate: ±0.3 K
Operational error limit in overall temperature range — Thermocouple, relative to input range, (+/-)Type B: > 600 °C ±4.6 K, type E: > -200 °C ±1.5 K, type J: > -210 °C ±1.9 K, type K: > -200 °C ±2.4 K, type N: > -200 °C ±2.9 K, type R: > 0 °C ±4.7 K, type S: > 0 °C ±4.6 K, type T: > -200 °C ±2.4 K
Basic error limit (operational limit at 25 °C) — Voltage, relative to input range, (+/-)0.1 %
Basic error limit (operational limit at 25 °C) — Current, relative to input range, (+/-)0.1 %
Basic error limit (operational limit at 25 °C) — Resistance, relative to input range, (+/-)0.1 %
Basic error limit (operational limit at 25 °C) — Resistance thermometer, relative to input range, (+/-)Ptxxx standard: ±0.7 K, Ptxxx climate: ±0.2 K, Nixxx standard: ±0.3 K, Nixxx climate: ±0.15 K
Basic error limit (operational limit at 25 °C) — Thermocouple, relative to input range, (+/-)Type B: > 600 °C ±1.7 K, type E: > -200 °C ±0.7 K, type J: > -210 °C ±0.8 K, type K: > -200 °C ±1.2 K, type N: > -200 °C ±1.2 K, type R: > 0 °C ±1.9 K, type S: > 0 °C ±1.9 K, type T: > -200 °C ±0.8 K
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency — Series mode interference (peak value of interference < rated value of input range), min.40 dB
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency — Common mode voltage, max.10 V
Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency — Common mode interference, min.60 dB

Interrupts/diagnostics/status information

Diagnostics functionYes
Alarms — Diagnostic alarmYes
Alarms — Limit value alarmYes; two upper and two lower limit values in each case
Diagnoses — Monitoring the supply voltageYes
Diagnoses — Wire breakYes; Only for 1 to 5 V, 4 to 20 mA, TC, R, and RTD
Diagnoses — Overflow/UnderflowYes
Diagnostics indication LED — RUN LEDYes; green LED
Diagnostics indication LED — ERROR LEDYes; red LED
Diagnostics indication LED — Monitoring of the supply voltage (PWR-LED)Yes; green LED
Diagnostics indication LED — Channel status displayYes; green LED
Diagnostics indication LED — for channel diagnosticsYes; red LED
Diagnostics indication LED — for module diagnosticsYes; red LED

Potential separation

Potential separation channels — between the channelsNo
Potential separation channels — between the channels, in groups of8
Potential separation channels — between the channels and backplane busYes
Potential separation channels — between the channels and the power supply of the electronicsYes

Permissible potential difference

between the inputs (UCM)20 V DC
Between the inputs and MANA (UCM)10 V DC

Isolation

Isolation tested with750 V DC (type test) and according to EN 50155 (routine test)

Standards, approvals, certificates

Suitable for applications according to AMS 2750Yes; Declaration of Conformity, see online support entry 109757262
Suitable for applications according to CQI-9Yes; Based on AMS 2750 E
Ecological footprint — environmental product declarationYes
Ecological footprint — Global warming potential — global warming potential, (total) [CO2 eq]38.6 kg
Ecological footprint — Global warming potential — global warming potential, (during production) [CO2 eq]14.4 kg
Ecological footprint — Global warming potential — global warming potential, (during operation) [CO2 eq]24.6 kg
Ecological footprint — Global warming potential — global warming potential, (after end of life cycle) [CO2 eq]-0.44 kg
Railway application — EN 50121-3-2Yes; EMC for rail vehicles
Railway application — EN 50121-4Yes; EMC for signal and telecommunications systems
Railway application — EN 50121-5Yes; EMC for fixed installations and railway power supply equipment
Railway application — EN 50124-1Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC
Railway application — EN 50125-1Yes; Rail vehicles - see ambient conditions
Railway application — EN 50125-2Yes; Stationary electrical equipment - see ambient conditions
Railway application — EN 50125-3Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track)
Railway application — EN 50155Yes; Rail vehicles - temperature class OT4, ST1/ST2, horizontal mounting position
Railway application — EN 61373Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B
Railway application — Fire protection acc. to EN 45545-2Yes; For proof of conformity, see Service & Support

Security

signed firmware updateNo
data integrityNo

Ambient conditions

Ambient temperature during operation — horizontal installation, min.-40 °C; = Tmin (incl. condensation/frost)
Ambient temperature during operation — horizontal installation, max.70 °C; = Tmax; +85 °C for 10 min (OT4, ST1/ST2 acc. to EN 50155)
Ambient temperature during operation — vertical installation, min.-40 °C; = Tmin
Ambient temperature during operation — vertical installation, max.40 °C; = Tmax
Altitude during operation relating to sea level — Installation altitude above sea level, max.2 000 m
Altitude during operation relating to sea level — Ambient air temperature-barometric pressure-altitudeTmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m)
Relative humidity — With condensation, tested in accordance with IEC 60068-2-38, max.100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation
Resistance — Coolants and lubricants — Resistant to commercially available coolants and lubricantsYes; Incl. diesel and oil droplets in the air
Resistance — Use in stationary industrial systems — to biologically active substances according to EN 60721-3-3Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request
Resistance — Use in stationary industrial systems — to chemically active substances according to EN 60721-3-3Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
Resistance — Use in stationary industrial systems — to mechanically active substances according to EN 60721-3-3Yes; Class 3S4 incl. sand, dust, *
Resistance — Use on land craft, rail vehicles and special-purpose vehicles — to biologically active substances according to EN 60721-3-5Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request
Resistance — Use on land craft, rail vehicles and special-purpose vehicles — to chemically active substances according to EN 60721-3-5Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); *
Resistance — Use on land craft, rail vehicles and special-purpose vehicles — to mechanically active substances according to EN 60721-3-5Yes; Class 5S3 incl. sand, dust; *
Resistance — Usage in industrial process technology — Against chemically active substances acc. to EN 60654-4Yes; Class 3 (excluding trichlorethylene)
Resistance — Usage in industrial process technology — Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil)
Resistance — Remark — Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04* The supplied plug covers must remain in place over the unused interfaces during operation!
Conformal coating — Coatings for printed circuit board assemblies acc. to EN 61086Yes; Class 2 for high reliability
Conformal coating — Protection against fouling acc. to EN 60664-3Yes; Type 1 protection
Conformal coating — Electronic equipment on rolling stock acc. to EN 50155Yes; Class PC2 protective coating acc. to EN 50155:2017
Conformal coating — Military testing according to MIL-I-46058C, Amendment 7Yes; Discoloration of coating possible during service life
Conformal coating — Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830AYes; Conformal coating, Class A

Dimensions

Width35 mm
Height147 mm
Depth129 mm

Weights

Weight, approx.310 g

Other

Note:for use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A, Online Support article 109736776

Downloads & documentation

Official documents from Siemens, downloaded directly from the manufacturer.

Data sheets & manuals

6AG2531-7KF00-4AB0: frequently asked questions

When can 6AG2531-7KF00-4AB0 be shipped?

6AG2531-7KF00-4AB0 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 6AG2531-7KF00-4AB0 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 6AG2531-7KF00-4AB0 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6AG2531-7KF00-4AB0, subject to availability and destination.

More Siemens parts

Siemens 6AG2526-1BH00-1AB0 – SIPLUS S7-1500 F-DI 16x24VDC HF T1 rail based on 6ES7526-1BH00-0AB0 with conformal coating, -30…+60 °C
Siemens
6AG2526-1BH00-1AB0

SIPLUS S7-1500 F-DI 16x24VDC HF T1 rail based on…

Siemens 6AG2526-2BF00-1AB0 – SIPLUS S7-1500 F-DQ 8x24VDC 2A T1 rail based on 6ES7526-2BF00-0AB0 with conformal coating, -30…+60 °C
Siemens
6AG2526-2BF00-1AB0

SIPLUS S7-1500 F-DQ 8x24VDC 2A T1 rail based on…

Siemens 6AG2541-1AD00-4AB0 – SIPLUS S7-1500 CM PTP RS232 HF TX rail based on 6ES7541-1AD00-0AB0 with conformal coating, -40…+70 °C
Siemens
6AG2541-1AD00-4AB0

SIPLUS S7-1500 CM PTP RS232 HF TX rail based on…

Siemens 6AG2542-6VX00-4XE0 – SIPLUS ET 200SP CP 1542SP-1 IRC TX rail based on 6GK7542-6VX00-0XE0 with conformal coating, -40…+70 °C
Siemens
6AG2542-6VX00-4XE0

SIPLUS ET 200SP CP 1542SP-1 IRC TX rail based on…

Siemens 6AG2590-0BD00-4AA0 – SIPLUS S7-1500 act. backplane 4 slot rail based on: 6ES7590-0BD00-0AA0 with conformal coating
Siemens
6AG2590-0BD00-4AA0

SIPLUS S7-1500 act. backplane 4 slot rail based on…

Siemens 6AG2531-7KF00-4AB0Price and lead time confirmed within 1 business day
Request a Quote