Siemens 6AG2135-6HB00-1DA1
SIPLUS ET 200SP AQ 2xU/I HS rail based on 6ES7135-6HB00-0DA1 with conformal coating, -40…+60 °C
- MPN
- 6AG2135-6HB00-1DA1
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Siemens 6AG2135-6HB00-1DA1?
SIPLUS ET 200SP AQ 2xU/I HS rail based on 6ES7135-6HB00-0DA1 with conformal coating, -40…+60 °C, OT2 with ST1/2 (+70 °C für 10 minutes), analog output module, suitable for BU type A0, A1, color code CC00, channel diagnostics, 16-bit, +/-0.2%
Specifications
General information
| Product type designation | AQ 2xU/I HS |
| based on | 6ES7135-6HB00-0DA1 |
| usable BaseUnits | BU type A0, A1 |
| Color code for module-specific color-coded label | CC00 |
| Product function — I&M data | Yes; I&M0 to I&M3 |
| Product function — Isochronous mode | Yes; 125 µs |
| Engineering with — STEP 7 TIA Portal configurable/integrated from version | see entry ID: 109746275 |
| Operating mode — Oversampling | Yes; 2 channels per module |
| Operating mode — MSO | No |
CiR - Configuration in RUN
| Reparameterization possible in RUN | Yes |
| Calibration possible in RUN | No |
Supply voltage
| Rated value (DC) | 24 V |
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
Input current
| Current consumption (rated value) | 45 mA; without load |
| Current consumption, max. | 90 mA; 2 channels current output 20 mA |
Power loss
| Power loss, typ. | 0.9 W |
Address area
| Address space per module — Address space per module, max. | 4 byte; + 1 byte for QI information (32 bytes in the oversampling operating mode) |
Hardware configuration
| Automatic encoding — Mechanical coding element | Yes |
| Automatic encoding — Type of mechanical coding element | Type A |
Analog outputs
| Number of analog outputs | 2 |
| Voltage output, short-circuit protection | Yes |
| Voltage output, short-circuit current, max. | 45 mA |
| Cycle time (all channels), min. | 125 µs |
| Analog output with oversampling | Yes |
| Analog output with oversampling — Values per cycle, max. | 16 |
| Analog output with oversampling — Resolution, min. | 45 µs; (2 channels), 35 µs (1 channel) |
| Output ranges, voltage — 0 to 10 V | Yes; 15 bit |
| Output ranges, voltage — 1 V to 5 V | Yes; 13 bit |
| Output ranges, voltage — 5 V to +5 V | Yes; 15 bit incl. sign |
| Output ranges, voltage — 10 V to +10 V | Yes; 16 bit incl. sign |
| Output ranges, current — 0 to 20 mA | Yes; 15 bit |
| Output ranges, current — 20 mA to +20 mA | Yes; 16 bit incl. sign |
| Output ranges, current — 4 mA to 20 mA | Yes; 14 bit |
| Connection of actuators — for voltage output two-wire connection | Yes |
| Connection of actuators — for voltage output four-wire connection | Yes |
| Connection of actuators — for current output two-wire connection | Yes |
| Load impedance (in rated range of output) — with voltage outputs, min. | 2 kΩ |
| Load impedance (in rated range of output) — with voltage outputs, capacitive load, max. | 1 µF |
| Load impedance (in rated range of output) — with current outputs, max. | 500 Ω |
| Load impedance (in rated range of output) — with current outputs, inductive load, max. | 1 mH |
| Destruction limits against externally applied voltages and currents — Voltages at the outputs | 30 V |
| Cable length — shielded, max. | 1 000 m; 200 m for voltage output |
Analog value generation for the outputs
| Integration and conversion time/resolution per channel — Resolution with overrange (bit including sign), max. | 16 bit |
| Settling time — for resistive load | 0.05 ms |
| Settling time — for capacitive load | 0.05 ms; Max. 47 nF and 20 m cable length |
| Settling time — for inductive load | 0.05 ms |
Errors/accuracies
| Output ripple (relative to output range, bandwidth 0 to 50 kHz), (+/-) | 0.02 % |
| Linearity error (relative to output range), (+/-) | 0.03 % |
| Temperature error (relative to output range), (+/-) | 0.003 %/K |
| Crosstalk between the outputs, max. | -50 dB |
| Repeat accuracy in steady state at 25 °C (relative to output range), (+/-) | 0.03 % |
| Operational error limit in overall temperature range — Voltage, relative to output range, (+/-) | 0.4 % |
| Operational error limit in overall temperature range — Current, relative to output range, (+/-) | 0.4 % |
| Basic error limit (operational limit at 25 °C) — Voltage, relative to output range, (+/-) | 0.1 % |
| Basic error limit (operational limit at 25 °C) — Current, relative to output range, (+/-) | 0.1 % |
Isochronous mode
| Execution and activation time (TCO), min. | 70 µs |
| Bus cycle time (TDP), min. | 125 µs |
Interrupts/diagnostics/status information
| Diagnostics function | Yes |
| Substitute values connectable | Yes |
| Alarms — Diagnostic alarm | Yes |
| Diagnoses — Monitoring the supply voltage | Yes |
| Diagnoses — Wire break | Yes; channel-by-channel, only for output type "current" |
| Diagnoses — Short-circuit | Yes; channel-by-channel, only for output type "voltage" |
| Diagnoses — Group error | Yes |
| Diagnoses — Overflow/Underflow | Yes |
| Diagnostics indication LED — Monitoring of the supply voltage (PWR-LED) | Yes; green PWR LED |
| Diagnostics indication LED — Channel status display | Yes; green LED |
| Diagnostics indication LED — for channel diagnostics | Yes; red LED |
| Diagnostics indication LED — for module diagnostics | Yes; green/red DIAG LED |
Potential separation
| Potential separation channels — between the channels | No |
| Potential separation channels — between the channels and backplane bus | Yes |
| Potential separation channels — between the channels and the power supply of the electronics | Yes |
Isolation
| Isolation tested with | 750 V DC (type test) and according to EN 50155 (routine test) |
Standards, approvals, certificates
| Railway application — EN 50121-3-2 | Yes; EMC for rail vehicles |
| Railway application — EN 50121-4 | Yes; EMC for signal and telecommunications systems |
| Railway application — EN 50121-5 | Yes; EMC for fixed installations and railway power supply equipment |
| Railway application — EN 50124-1 | Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC |
| Railway application — EN 50125-1 | Yes; Rail vehicles - see ambient conditions |
| Railway application — EN 50125-2 | Yes; Stationary electrical equipment - see ambient conditions |
| Railway application — EN 50125-3 | Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track) |
| Railway application — EN 50155 | Yes; Rail vehicles - temperature class OT2, ST1/ST2, horizontal mounting position |
| Railway application — EN 61373 | Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B |
| Railway application — Fire protection acc. to EN 45545-2 | Yes; Rail vehicles - verification on request |
Ambient conditions
| Ambient temperature during operation — horizontal installation, min. | -40 °C; = Tmin (incl. condensation/frost) |
| Ambient temperature during operation — horizontal installation, max. | 60 °C; = Tmax; +70 °C for 10 min (OT2, ST1/ST2 acc. to EN 50155); +70 °C continuously with spacing modules (6AG2193-6BN00-4BA0) or configured slots to the left and right of the module (OT4, ST0 acc. to EN 50155) |
| Ambient temperature during operation — vertical installation, min. | -40 °C; = Tmin |
| Ambient temperature during operation — vertical installation, max. | 50 °C; = Tmax |
| Altitude during operation relating to sea level — Installation altitude above sea level, max. | 2 000 m |
| Altitude during operation relating to sea level — Ambient air temperature-barometric pressure-altitude | Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) |
| Relative humidity — With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation |
| Resistance — Coolants and lubricants — Resistant to commercially available coolants and lubricants | Yes; Incl. diesel and oil droplets in the air |
| Resistance — Use in stationary industrial systems — to biologically active substances according to EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
| Resistance — Use in stationary industrial systems — to chemically active substances according to EN 60721-3-3 | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
| Resistance — Use in stationary industrial systems — to mechanically active substances according to EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust, * |
| Resistance — Use in stationary industrial systems — Against mechanical environmental conditions acc. to EN 60721-3-3 | Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) |
| Resistance — Use on land craft, rail vehicles and special-purpose vehicles — to biologically active substances according to EN 60721-3-5 | Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request |
| Resistance — Use on land craft, rail vehicles and special-purpose vehicles — to chemically active substances according to EN 60721-3-5 | Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
| Resistance — Use on land craft, rail vehicles and special-purpose vehicles — to mechanically active substances according to EN 60721-3-5 | Yes; Class 5S3 incl. sand, dust; * |
| Resistance — Use on land craft, rail vehicles and special-purpose vehicles — Against mechanical environmental conditions acc. to EN 60721-3-5 | Yes; Class 5M2 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) |
| Resistance — Usage in industrial process technology — Against chemically active substances acc. to EN 60654-4 | Yes; Class 3 (excluding trichlorethylene) |
| Resistance — Usage in industrial process technology — Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04 | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) |
| Resistance — Remark — Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04 | * The supplied plug covers must remain in place over the unused interfaces during operation! |
| Conformal coating — Coatings for printed circuit board assemblies acc. to EN 61086 | Yes; Class 2 for high reliability |
| Conformal coating — Protection against fouling acc. to EN 60664-3 | Yes; Type 1 protection |
| Conformal coating — Electronic equipment on rolling stock acc. to EN 50155 | Yes; Class PC2 protective coating acc. to EN 50155:2017 |
| Conformal coating — Military testing according to MIL-I-46058C, Amendment 7 | Yes; Discoloration of coating possible during service life |
| Conformal coating — Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A | Yes; Conformal coating, Class A |
Dimensions
| Width | 15 mm |
| Height | 73 mm |
| Depth | 58 mm |
Weights
| Weight, approx. | 31 g |
Other
| Note: | for use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A, Online Support article 109736776 |
No matching specifications
Downloads & documentation
Official documents from Siemens, downloaded directly from the manufacturer.
Data sheets & manuals
6AG2135-6HB00-1DA1: frequently asked questions
When can 6AG2135-6HB00-1DA1 be shipped?
6AG2135-6HB00-1DA1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 6AG2135-6HB00-1DA1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 6AG2135-6HB00-1DA1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6AG2135-6HB00-1DA1, subject to availability and destination.
More Siemens parts