Siemens 6AG2134-6PA20-4BD0
SIPLUS ET 200SP AI Energy Meter 480VAC TX rail based on 6ES7134-6PA20-0BD0 with conformal coating, -40…+70 °C
- MPN
- 6AG2134-6PA20-4BD0
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Siemens 6AG2134-6PA20-4BD0?
SIPLUS ET 200SP AI Energy Meter 480VAC TX rail based on 6ES7134-6PA20-0BD0 with conformal coating, -40…+70 °C, OT4 with ST1/2 (+85 °C for 10 minutes), analog input module, suitable for BU type D0, channel diagnostics
Specifications
General information
| Product type designation | AI Energy Meter 480VAC ST |
| based on | 6ES7134-6PA20-0BD0 |
| usable BaseUnits | BU type D0 |
| Product function — Voltage measurement | Yes |
| Product function — Voltage measurement — with voltage transformer | Yes |
| Product function — Current measurement | Yes |
| Product function — Current measurement — without current transformer | No |
| Product function — Current measurement — with current transformer | Yes |
| Product function — Energy measurement | Yes |
| Product function — Frequency measurement | Yes |
| Product function — Power measurement | Yes |
| Product function — Active power measurement | Yes |
| Product function — Reactive power measurement | Yes |
| Product function — I&M data | Yes; I&M0 to I&M3 |
| Product function — Isochronous mode | No |
| Engineering with — STEP 7 TIA Portal configurable/integrated from version | see entry ID: 109746275 |
| Operating mode — cyclic measurement | Yes |
| Operating mode — acyclic measurement | Yes |
| Operating mode — Acyclic measured value access | Yes |
| Operating mode — Fixed measured value sets | Yes |
| Operating mode — Freely definable measured value sets | Yes |
CiR - Configuration in RUN
| Reparameterization possible in RUN | Yes |
| Calibration possible in RUN | Yes |
Installation type/mounting
| Mounting position | any |
Supply voltage
| Design of the power supply | Supply via voltage measurement channel L1 |
| Rated value (AC) | AC 100 - 277 V |
| permissible range, lower limit (AC) | 90 V; At < -25 °C min. permissible supply voltage 110 V AC |
| permissible range, upper limit (AC) | 293 V |
| Line frequency — permissible range, lower limit | 47 Hz |
| Line frequency — permissible range, upper limit | 63 Hz |
Power loss
| Power loss, typ. | 0.6 W |
Address area
| Address space per module — Address space per module, max. | 268 byte; 256 byte input / 12 byte output |
Hardware configuration
| Automatic encoding — Mechanical coding element | Yes |
Time of day
| Operating hours counter — present | Yes |
Analog inputs
| Cycle time (all channels), typ. | 50 ms; Time for consistent update of all measured and calculated values (cyclic und acyclic data) |
Interrupts/diagnostics/status information
| Alarms — Diagnostic alarm | Yes |
| Alarms — Limit value alarm | Yes |
| Alarms — Hardware interrupt | Yes; Monitoring of up to 16 freely selectable process values (exceeding or undershooting of value) |
| Diagnostics indication LED — Monitoring of the supply voltage (PWR-LED) | Yes |
| Diagnostics indication LED — Channel status display | Yes; green LED |
| Diagnostics indication LED — for channel diagnostics | Yes; red Fn LED |
| Diagnostics indication LED — for module diagnostics | Yes; green/red DIAG LED |
Integrated Functions
| Measuring functions — Measuring procedure for voltage measurement | TRMS |
| Measuring functions — Measuring procedure for current measurement | TRMS |
| Measuring functions — Type of measured value acquisition | seamless |
| Measuring functions — Curve shape of voltage | Sinusoidal or distorted |
| Measuring functions — Buffering of measured variables | Yes |
| Measuring functions — Parameter length | 74 byte |
| Measuring functions — Bandwidth of measured value acquisition | 2 kHz; Harmonics: 39 / 50 Hz, 32 / 60 Hz |
| Measuring functions — Measuring range — Frequency measurement, min. | 45 Hz |
| Measuring functions — Measuring range — Frequency measurement, max. | 65 Hz |
| Measuring functions — Measuring inputs for voltage — Measurable line voltage between phase and neutral conductor | 277 V |
| Measuring functions — Measuring inputs for voltage — Measurable line voltage between the line conductors | 480 V |
| Measuring functions — Measuring inputs for voltage — Measurable line voltage between phase and neutral conductor, min. | 90 V |
| Measuring functions — Measuring inputs for voltage — Measurable line voltage between phase and neutral conductor, max. | 293 V |
| Measuring functions — Measuring inputs for voltage — Measurable line voltage between the line conductors, min. | 155 V |
| Measuring functions — Measuring inputs for voltage — Measurable line voltage between the line conductors, max. | 508 V |
| Measuring functions — Measuring inputs for voltage — Internal resistance line conductor and neutral conductor | 3.4 MΩ |
| Measuring functions — Measuring inputs for voltage — Power consumption per phase | 20 mW |
| Measuring functions — Measuring inputs for voltage — Impulse voltage resistance 1,2/50µs | 1 kV |
| Measuring functions — Measuring inputs for voltage — Measurement category for voltage measurement in accordance with IEC 61010-2-030 | CAT II; CAT III in case of guaranteed protection level of 1.5 kV |
| Measuring functions — Measuring inputs for current — measurable relative current (AC), min. | 1 %; Relative to the secondary rated current 5 A |
| Measuring functions — Measuring inputs for current — measurable relative current (AC), max. | 100 %; Relative to the secondary rated current 5 A |
| Measuring functions — Measuring inputs for current — Continuous current with AC, maximum permissible | 5 A; at > +60 °C max. permissible current 1 A per phase |
| Measuring functions — Measuring inputs for current — Apparent power consumption per phase for measuring range 5 A | 0.6 VA |
| Measuring functions — Measuring inputs for current — Rated value short-time withstand current restricted to 1 s | 100 A |
| Measuring functions — Measuring inputs for current — Input resistance measuring range 0 to 5 A | 25 mΩ; At the terminal |
| Measuring functions — Measuring inputs for current — Surge strength | 10 A; for 1 minute |
| Measuring functions — Measuring inputs for current — Zero point suppression | Parameterizable: 2 ... 250 mA, default 50 mA |
| Measuring functions — Accuracy class according to IEC 61557-12 — Measured variable voltage | 0,2 |
| Measuring functions — Accuracy class according to IEC 61557-12 — Measured variable current | 0,2 |
| Measuring functions — Accuracy class according to IEC 61557-12 — Measured variable apparent power | 0.5 |
| Measuring functions — Accuracy class according to IEC 61557-12 — Measured variable active power | 0.5 |
| Measuring functions — Accuracy class according to IEC 61557-12 — Measured variable reactive power | 1 |
| Measuring functions — Accuracy class according to IEC 61557-12 — Measured variable power factor | 0.5 |
| Measuring functions — Accuracy class according to IEC 61557-12 — Measured variable active energy | 0.5 |
| Measuring functions — Accuracy class according to IEC 61557-12 — Measured variable reactive energy | 1 |
| Measuring functions — Accuracy class according to IEC 61557-12 — Measured variable neutral current | 0.5; calculated |
| Measuring functions — Accuracy class according to IEC 61557-12 — Measured variable phase angle | ±1 °; not covered by IEC 61557-12 |
| Measuring functions — Accuracy class according to IEC 61557-12 — Measured variable frequency | 0.05 |
Potential separation
| Potential separation channels — between the channels and backplane bus | Yes; 3 700V AC (type test) CAT III |
Isolation
| Isolation tested with | 2 545 V DC (type test) and according to EN 50155 (routine test) |
Standards, approvals, certificates
| Railway application — EN 50121-3-2 | Yes; EMC for rail vehicles |
| Railway application — EN 50121-4 | Yes; EMC for signal and telecommunications systems |
| Railway application — EN 50124-1 | Yes; Railway applications - overvoltage category OV3; pollution degree PD2; UNm = 277/480 V AC |
| Railway application — EN 50125-1 | Yes; Rail vehicles - see ambient conditions |
| Railway application — EN 50125-2 | Yes; Stationary electrical equipment - see ambient conditions |
| Railway application — EN 50125-3 | Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track) |
| Railway application — EN 50155 | Yes; Rail vehicles - temperature class OT4, ST1/ST2, horizontal mounting position |
| Railway application — EN 61373 | Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B |
| Railway application — Fire protection acc. to EN 45545-2 | Yes; For proof of conformity, see Service & Support |
Ambient conditions
| Ambient temperature during operation — horizontal installation, min. | -40 °C; = Tmin (incl. condensation/frost) |
| Ambient temperature during operation — horizontal installation, max. | 70 °C; = Tmax; +85 °C for 10 min (OT4, ST1/ST2 acc. to EN 50155) |
| Ambient temperature during operation — vertical installation, min. | -40 °C; = Tmin |
| Ambient temperature during operation — vertical installation, max. | 50 °C; = Tmax |
| Altitude during operation relating to sea level — Installation altitude above sea level, max. | 2 000 m |
| Altitude during operation relating to sea level — Ambient air temperature-barometric pressure-altitude | Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) |
| Relative humidity — With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation |
| Resistance — Coolants and lubricants — Resistant to commercially available coolants and lubricants | Yes; Incl. diesel and oil droplets in the air |
| Resistance — Use in stationary industrial systems — to biologically active substances according to EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
| Resistance — Use in stationary industrial systems — to chemically active substances according to EN 60721-3-3 | Yes; Class 3C4 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
| Resistance — Use in stationary industrial systems — to mechanically active substances according to EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust, * |
| Resistance — Use in stationary industrial systems — Against mechanical environmental conditions acc. to EN 60721-3-3 | Yes; Class 3M8 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) |
| Resistance — Use on land craft, rail vehicles and special-purpose vehicles — to biologically active substances according to EN 60721-3-5 | Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request |
| Resistance — Use on land craft, rail vehicles and special-purpose vehicles — to chemically active substances according to EN 60721-3-5 | Yes; Class 5C3 (RH < 75 %) incl. salt spray acc. to EN 60068-2-52 (severity degree 3); * |
| Resistance — Use on land craft, rail vehicles and special-purpose vehicles — to mechanically active substances according to EN 60721-3-5 | Yes; Class 5S3 incl. sand, dust; * |
| Resistance — Use on land craft, rail vehicles and special-purpose vehicles — Against mechanical environmental conditions acc. to EN 60721-3-5 | Yes; Class 5M2 using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) |
| Resistance — Use on land craft, rail vehicles and special-purpose vehicles — against mechanical environmental conditions in agriculture acc. to ISO 15003 | Yes; level 1 (Location LE) using the SIPLUS Mounting Kit ET 200SP (6AG1193-6AA00-0AA0) |
| Resistance — Usage in industrial process technology — Against chemically active substances acc. to EN 60654-4 | Yes; Class 3 (excluding trichlorethylene) |
| Resistance — Usage in industrial process technology — Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04 | Yes; Level GX group A/B (excluding trichlorethylene; harmful gas concentrations up to the limits of EN 60721-3-3 class 3C4 permissible); level LC3 (salt spray) and level LB3 (oil) |
| Resistance — Remark — Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04 | * The supplied plug covers must remain in place over the unused interfaces during operation! |
| Conformal coating — Coatings for printed circuit board assemblies acc. to EN 61086 | Yes; Class 2 for high reliability |
| Conformal coating — Protection against fouling acc. to EN 60664-3 | Yes; Type 1 protection |
| Conformal coating — Electronic equipment on rolling stock acc. to EN 50155 | Yes; Class PC2 protective coating acc. to EN 50155:2017 |
| Conformal coating — Military testing according to MIL-I-46058C, Amendment 7 | Yes; Discoloration of coating possible during service life |
| Conformal coating — Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A | Yes; Conformal coating, Class A |
Dimensions
| Width | 20 mm |
| Height | 73 mm |
| Depth | 58 mm |
Weights
| Weight, approx. | 45 g |
Other
| Note: | for use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A, Online Support article 109736776 |
| Data for selecting a current transformer — Burden power current transformer x/1A, min. | As a function of cable length and cross section, see device manual |
| Data for selecting a current transformer — Burden power current transformer x/5A, min. | As a function of cable length and cross section, see device manual |
No matching specifications
Downloads & documentation
Official documents from Siemens, downloaded directly from the manufacturer.
Data sheets & manuals
6AG2134-6PA20-4BD0: frequently asked questions
When can 6AG2134-6PA20-4BD0 be shipped?
6AG2134-6PA20-4BD0 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 6AG2134-6PA20-4BD0 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 6AG2134-6PA20-4BD0 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6AG2134-6PA20-4BD0, subject to availability and destination.
More Siemens parts