Siemens 3VA9243-0JC13
Wire connector TA2.2 2 AWG...350 kcmil large with control wire voltage tap 3 units accessory for: 3VA61/62
- MPN
- 3VA9243-0JC13
- Category
- Accessories and Spare Parts
Request a Quote
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- Ships via
- 100% positive eBay feedback
What is the Siemens 3VA9243-0JC13?
wire connector TA2.2 2 AWG...350 kcmil large with control wire voltage tap 3 units accessory for: 3VA61/62
Specifications
Model
| product brand name | SENTRON |
| product designation | circular conductor terminal |
| design of the product | Connection method |
| accessories | Wire connector |
General technical data
| designation / of the terminal | TA2.2 |
| type of electrical connection / with control wire tap | Yes |
Mechanical Design
| Net Weight | 493 g |
Connections according IEC
| connectable conductor cross-section — for copper cable / stranded / minimum | 50 mm² |
| connectable conductor cross-section — for copper cable / stranded / maximum | 240 mm² |
| connectable conductor cross-section — for aluminum cable / stranded / minimum | 50 mm² |
| connectable conductor cross-section — for aluminum cable / stranded / maximum | 240 mm² |
| stripped length | 30,5 mm |
| tightening torque / when using copper cables — stranded | 50 - 240 mm²: 31.1 Nm |
| tightening torque / when using copper cables — finely stranded | 50 - 185 mm²: 31.1 Nm |
| tightening torque / when using copper cables — finely stranded / with core end processing | 50 - 185 mm²: 31.1 Nm |
Connetctions according UL
| permissible temperature / of connectable conductor / according to UL 486A-486B | 75 °C |
| stripped length | 1.2 in |
| connectable conductor cross-section — for copper cable / stranded / minimum | 2 AWG |
| connectable conductor cross-section — for copper cable / stranded / maximum | 350 kcmil |
| connectable conductor cross-section — for aluminum cable / stranded / minimum | 2 AWG |
| connectable conductor cross-section — for aluminum cable / stranded / maximum | 350 kcmil |
| tightening torque / when using copper cables — stranded | 2 AWG - 350 kcmil: 275 lb-in |
Downloads & documentation
Official documents from Siemens, downloaded directly from the manufacturer.
Data sheets & manuals
3VA9243-0JC13: frequently asked questions
When can 3VA9243-0JC13 be shipped?
3VA9243-0JC13 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 3VA9243-0JC13 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 3VA9243-0JC13 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 3VA9243-0JC13, subject to availability and destination.
More Siemens parts