energy sensor PowerTag Monoconnect 250A 3P+N
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | PowerLogic™ PowerTag Energy Sensors |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.3 kg |
Shipping & availability
When can LV434021 be shipped?
LV434021 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up LV434021 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for LV434021 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LV434021, subject to availability and destination.
This PowerTag Energy M250 3P+N is a wireless communication energy sensor. With its Monoconnect design, it is dedicated to Compact NSX 100/160/250, Compact NS 100/160/250, Compact INS250 and Compact INV 100/160/200/250. It has to be associated with a concentror or a gateway to provide circuit monitoring and diagnosis down to load level. It is designed specifically for Energy Management, Load Monitoring and Power Availability applications. It incorporates accurate real-time measurements of active, and reactive energy, active, reactive and apparent power, current, voltage and power factor. In case of power outage, it sends a voltage loss alarm and the current-per-phase value before being de-energized. PowerTag Energy M250 complies with IEC 61557-12 standard. It is a PMD-II/DD/K70/1. The Performance category is Class 1. The Imax maximum current is 250A. The Ib Base current is 40A. The Saturation current is 500A and the Ist Starting current is 160mA. The Un Rated voltages are Phase-to-neutral 230VAC +/- 20% and Phase-to-phase 400VAC +/- 20%. The maximum consumption is below or equal to 3.7VA. It can be mounted directly on the bottom side of the circuit breaker or Vigi add-on terminals, or top or bottom side of the plug-in base if any. The product color is grey (RAL7016). The weight is 300g. The degree of protection is IP20 and IK07. The operating temperature is between -25°C to +70°C. The storage temperature is between -50°C to +85°C.
Specifications
Specifications
| Range of product | PowerLogic |
| Product name | PowerTag M250 |
| Product or component type | Energy sensor |
| Poles | 3P + N |
| Maximum current [Imax] | 250 A |
| [Ib] Basic current | 40 A |
| Starting current | 160 mA |
| Saturation current | 500 A |
| Product specific application | Energy management, Overload alarm, Power factor, Load monitoring, Circuit monitoring |
| Concentrator compatibility | EcoStruxure Panel Server Entry, EcoStruxure Panel Server Universal, EcoStruxure Panel Server Advanced, Harmony Hub, Acti9 Smartlink SI B, Acti9 Smartlink SI D, Acti9 PowerTag Link, Acti9 PowerTag Link HD |
| Range compatibility | ComPacT ComPacT NSX NSX100, ComPacT ComPacT NSX NSX250, ComPacT Compact INV Interpact INV100, ComPacT Compact INV Interpact INV250, Compact NS Compact NS100, Compact NS Compact NS250, ComPacT ComPacT INS INS250, EasyPact EasyPact CVS100, EasyPact EasyPact CVS160, EasyPact EasyPact CVS250 |
| Type of measurement | Active and reactive energy, Active and reactive power, Apparent power, Current, Voltage, Power factor |
| Accuracy class | Class 1 active energy conforming to IEC 61557-12, Class 2 reactive energy conforming to IEC 61557-12, Class 1 active power conforming to IEC 61557-12, Class 2 reactive power conforming to IEC 61557-12, Class 2 apparent power conforming to IEC 61557-12, Class 1 current conforming to IEC 61557-12, Class 0.5 voltage conforming to IEC 61557-12, Class 1 power factor conforming to IEC 61557-12 |
| Metering type | Power factor 0...1: class 1 at 25 °C conforming to IEC 61557-12, Active energy Ep IN/OUT/tot 0...281 x 10exp(9) kWh: class 1 at 25 °C conforming to IEC 61557-12, Reactive energy Ep IN/OUT/tot 0...281 x 10exp(9) kVARh: class 2 at 25 °C conforming to IEC 61557-12, Voltage U12, U23, U31 320...480 V: class 0.5 at 25 °C conforming to IEC 61557-12, Voltage V1N, V2N, V3N 184...276 V: class 0.5 at 25 °C conforming to IEC 61557-12, Current I1, I2, I3, Iavg 8...250 A: class 1 at 25 °C conforming to IEC 61557-12, Apparent power S, S1, S2, S3 88 VA...416 kVA: class 2 at 25 °C conforming to IEC 61557-12, Active power P, P1, P2, P3 88 W...416 kW: class 1 at 25 °C conforming to IEC 61557-12, Reactive power Q, Q1, Q2, Q3 88 VAR...416 kVAR: class 2 at 25 °C conforming to IEC 61557-12, Frequency 45...65 Hz |
| Mounting location | Bottom |
| Mounting support | On circuit breaker |
| Connection pitch | 35 mm |
| Product destination | Switchboard |
| Event management | Voltage loss with measured current at voltage loss |
| Transmission support medium | Radio frequency 2.4…2.4835 GHz conforming to IEEE 802.15.4 (11…26) transmission time < 5 ms |
| Emission power | 10 mW |
| [Imp] maximum permanent current | 1.2 x In |
| Form factor | Monoconnect |
| Mounting mode | Bolt-on |
| Tightening torque | 10 N.m |
| supply voltage | 230 V AC, +/- 20 %, between phase and neutral, 400 V AC, +/- 20 %, between phases |
| Network frequency | 50 Hz, 60 Hz |
| Maximum power consumption | 3.7 VA |
| Standards | IEC 61557-12, IEC 61010-1, ETSI EN 301 489-1, IEC 61010-2-030, IEC 61326-1, ETSI EN 300 328 |
| Product certifications | IEC, DNV Marine |
| Height | 57 mm |
| Width | 140 mm |
| Depth | 86 mm |
| Net weight | 300 g |
| Colour | Dark grey (RAL 7016) |
| Quality labels | CE |
| Directives | 2014/53/EU - radio equipment directive |
| Operating altitude | 0...2000 m |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -50…85 °C |
| Overvoltage category | IV conforming to IEC 61010-1 |
| Measurement category | Category III conforming to IEC 61010-2-030 |
| IP degree of protection | IP20 |
| IK degree of protection | IK07 conforming to IEC 60068-2-75 test Ehb |
| Pollution degree | 3 |
| Relative humidity | 0…95 % at 55 °C conforming to IEC 60721-3-3 |
| Vibration resistance | 3M4 conforming to IEC 60721-3-3 |
| Electromagnetic compatibility | Industrial electromagnetic environment conforming to IEC 61326-1, Radiated EMC conforming to ETSI EN 301 489-17, Electromagnetic emission conforming to IEC 62311 |
| environmental characteristics | Indoor use |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 13.000 cm |
| Package 1 Width | 11.000 cm |
| Package 1 Length | 17.300 cm |
| Package 1 Weight | 546.000 g |
| Unit Type of Package 2 | S02 |
| Number of Units in Package 2 | 4 |
| Package 2 Height | 15.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 2.630 kg |
| Unit Type of Package 3 | P06 |
| Number of Units in Package 3 | 64 |
| Package 3 Height | 71.500 cm |
| Package 3 Width | 60.000 cm |
| Package 3 Length | 80.000 cm |
| Package 3 Weight | 54.080 kg |
| Warranty (in months) | 18 |
More Schneider Electric parts