Available on request

Schneider Electric ATV71LD27N4Z – variable speed drive Altivar Lift, 11 kW 15 Hp, 380...480 V three-phase, EMC filter, with heat sink

MPN: ATV71LD27N4Z · Brand: Schneider Electric
Price on request

Discontinued by Schneider Electric — we can still source the original ATV71LD27N4Z (new, used or refurbished, subject to availability). Request a quote below.

Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryAltivar 71
LifecycleDiscontinued
Warranty12-month (new) · 3-month (used/refurbished)
UPC / EAN3606480326264
DatasheetManufacturer datasheet ↗

Shipping & availability

Can I still buy the ATV71LD27N4Z now that it is discontinued?

Yes. Schneider Electric has discontinued the ATV71LD27N4Z, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time.

When can ATV71LD27N4Z be shipped?

ATV71LD27N4Z is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up ATV71LD27N4Z in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for ATV71LD27N4Z and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for ATV71LD27N4Z, subject to availability and destination.

This Altivar Lift variable speed drive can feed 3-phase asynchronous and asynchronous motors (with or without encoder). It is designed with heatsink and it has a built-in EMC filter. It works at a rated supply voltage from 380V to 480V AC. This drive has been specially designed with and for professionals. It features advanced functions like half-floor control, inspection mode, rollback management, direct to floor, evacuation with UPS, load measurement, deferred thermal stop. It is suitable for motors with power rating up to 11 kW / 15 hp. Its dimensions are, 230mm wide, 400mm high, 187mm deep. This drive provides precision and durability for your lift applications. It complies with lift standards EN 12015 and EN 12016 without external filter. Accessories like remote graphic display terminal, simple loader tool and options like encoder interface cards, I/O cards are available with Altivar Lift drives. Discontinued by Schneider Electric. PartnerPLC sources discontinued and surplus Schneider Electric automation parts — request a quote for price, condition and lead time.

Specifications

Main

Device short nameATV71
Product destinationSynchronous motors; Asynchronous motors
Network number of phases3 phases
Supply voltage limits323…528 V
Supply frequency50...60 Hz - 5...5 %
Motor power kW11 kW, 3 phases at 380...480 V
Motor power hp15 hp, 3 phases at 380...480 V
Line current36.6 A for 380 V 3 phases 11 kW / 15 hp; 30 A for 480 V 3 phases 11 kW / 15 hp
Range of productAltivar Lift
Product or component typeVariable speed drive
Product specific applicationLift
VariantWith integrated 7-segment display terminal
Communication port protocolCANopen; Modbus
[Us] rated supply voltage380...480 V - 15...10 %
EMC filterIntegrated

Complementary

Apparent power24.1 kVA at 380 V 3 phases 11 kW / 15 hp
Prospective line Isc22 kA for 3 phases
Nominal output current27.7 A at 4 kHz 380 V 3 phases 11 kW / 15 hp; 21 A at 4 kHz 460 V 3 phases 11 kW / 15 hp
Maximum transient current37.7 A for 2 s 3 phases / 11 kW / 15 hp
Speed drive output frequency0…599 Hz
Speed range1…100 for asynchronous motor in open-loop mode, without speed feedback; 1…50 for synchronous motor in open-loop mode, without speed feedback; 1…1000 for asynchronous motor in closed-loop mode with encoder feedback
Torque accuracy+/- 5 % in closed-loop mode with encoder feedback; +/- 15 % in open-loop mode, without speed feedback
Transient overtorque170 %, +/- 10 % for 60 s; 220 %, +/- 10 % for 2 s
Braking torque30 % without braking resistor; <= 150 % with braking or hoist resistor
Local signalling1 LED (red) for drive voltage
Output voltage<= power supply voltage
InsulationElectrical between power and control
type of cable for external connectionWithout mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR; Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC; With an IP21 or an IP31 kit: 3 wire(s)IEC cable at 40 °C, copper 70 °C / PVC; With a NEMA Type1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC
Electrical connectionTerminal, clamping capacity: 2.5 mm², 14 AWG (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR); Terminal, clamping capacity: 16 mm², 4 AWG (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)
Tightening torque3 N.m, 26.5 lb.in (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB); 0.6 N.m (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR)
SupplyInternal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 A, protection type: overload and short-circuit protection; Internal supply: 24 V DC (21…27 V), <200 A, protection type: overload and short-circuit protection
Sampling duration2 ms +/- 0.5 ms (LI6)if configured as logic input - discrete input(s); 2 ms +/- 0.5 ms (LI1...LI5) - discrete input(s); 2 ms +/- 0.5 ms (AI1-/Al1+) - analog input(s); 2 ms +/- 0.5 ms (Al2) - analog input(s)
Response timeR1A, R1B, R1C 7 ms, tolerance +/- 0.5 ms for discrete output(s); R2A, R2B 7 ms, tolerance +/- 0.5 ms for discrete output(s); AO1 2 ms, tolerance +/- 0.5 ms for analog output(s); <= 100 ms in STO (Safe Torque Off)
Accuracy+/- 0.6 % (AI1-/Al1+) for a temperature variation 60 °C; +/- 0.6 % (AI2) for a temperature variation 60 °C; +/- 1 % (AO1) for a temperature variation 60 °C
Linearity error+/- 0.15 % of maximum value (AI1-/Al1+, AI2); +/- 0.2 % (AO1)
Analogue output typeAO1 software-configurable voltage: 0...10 V DC, impedance: 470 Ohm, resolution 10 bits; AO1 software-configurable current: 0...20 mA, impedance: 500 Ohm, resolution 10 bits; AO1 software-configurable logic output 10 V 20 A
Discrete output typeConfigurable relay logic: (R1A, R1B, R1C) NO/NC - 100000 cycles; Configurable relay logic: (R2A, R2B) NO - 100000 cycles
Minimum switching current3 mA at 24 V DC for configurable relay logic
Maximum switching current5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (R1, R2); 5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (R1, R2); 2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (R1, R2); 2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (R1, R2)
Discrete input typeProgrammable (LI1...LI5)24 V DC, with level 1 PLC - 3500 Ohm; Switch-configurable (LI6)24 V DC, with level 1 PLC - 3500 Ohm; Switch-configurable PTC probe (LI6) - 0…6 probes - 1500 Ohm; Safety input (PWR)24 V DC - 1500 Ohm
Discrete input logicPositive logic (LI6)if configured as logic input, < 5 V (state 0), > 11 V (state 1); Negative logic (LI6)if configured as logic input, > 16 V (state 0), < 10 V (state 1); Positive logic (LI1...LI5), < 5 V (state 0), > 11 V (state 1); Negative logic (LI1...LI5), > 16 V (state 0), < 10 V (state 1); Positive logic (PWR), < 2 V (state 0), > 17 V (state 1)
Dielectric strength3535 V DC between earth and power terminals; 5092 V DC between control and power terminals
Insulation resistance> 1 mOhm 500 V DC for 1 minute to earth
Frequency resolutionDisplay unit: 0.1 Hz; Analog input: 0.024/50 Hz
Connector type1 RJ45 (on front face) for Modbus; 1 RJ45 (on terminal) for Modbus; Male SUB-D 9 on RJ45 for CANopen
Physical interface2-wire RS 485 for Modbus
Transmission frameRTU for Modbus
Transmission rate9600 bps, 19200 bps for Modbus on front face; 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal; 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen
Data format8 bits, 1 stop, even parity for Modbus on front face; 8 bits, odd even or no configurable parity for Modbus on terminal
Type of polarizationNo impedance for Modbus
Number of addresses1…247 for Modbus; 1…127 for CANopen
control optionsCommunication card for Modbus TCP; Communication card for Fipio; Communication card for Modbus/Uni-Telway; Communication card for Modbus Plus; Communication card for EtherNet/IP; Communication card for DeviceNet; Communication card for Profibus DP; Communication card for Profibus DP V1; Communication card for Interbus-S; Communication card for CC-Link; Interface card for encoder; I/O extension card; Controller inside programmable card; Overhead crane card
Discrete input number7
Discrete output number2
Analogue input number2
Analogue input typeAI2 software-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 11 bits; AI1-/Al1+ bipolar differential voltage: +/- 10 V DC 24 V max, resolution 11 bits + sign; AI2 software-configurable current: 0...20 mA, impedance: 242 Ohm, resolution 11 bits
Analogue output number1
Method of accessSlave CANopen
Asynchronous motor control profileVoltage/frequency ratio, 2 points; Flux vector control without sensor, standard; Flux vector control without sensor, ENA (energy Adaptation) system; Voltage/frequency ratio - Energy Saving, quadratic U/f; Flux vector control without sensor, 2 points; Voltage/frequency ratio, 5 points; Flux vector control with sensor, standard
Synchronous motor control profileVector control with sensor, standard; Vector control without sensor, standard
Acceleration and deceleration rampsS, U or customized; Linear adjustable separately from 0.01 to 9000 s; Automatic adaptation of ramp if braking capacity exceeded, by using resistor
Motor slip compensationAutomatic whatever the load; Suppressable; Adjustable; Not available in voltage/frequency ratio (2 or 5 points)
Switching frequency1...16 kHz adjustable
Nominal switching frequency8 kHz
Minimum braking resistance7 Ohm
Network frequency47.5...63 Hz
Protection typeOverheating protection: drive; Thermal protection: drive; Short-circuit between motor phases: drive; Input phase breaks: drive; Overcurrent between output phases and earth: drive; Overvoltages on the DC bus: drive; Break on the control circuit: drive; Against exceeding limit speed: drive; Line supply undervoltage: drive; Line supply overvoltage: drive; Against input phase loss: drive; Thermal protection: motor; Motor phase break: motor; Power removal: motor

Environment

Pollution degree2 conforming to IEC 61800-5-1
IP degree of protectionIP20 on upper part without blanking plate on cover conforming to IEC 61800-5-1; IP20 on upper part without blanking plate on cover conforming to IEC 60529; IP21 conforming to IEC 61800-5-1; IP21 conforming to IEC 60529; IP41 on upper part conforming to IEC 61800-5-1; IP41 on upper part conforming to IEC 60529; IP54 on lower part conforming to IEC 61800-5-1; IP54 on lower part conforming to IEC 60529
Vibration resistance1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Shock resistance15 gn for 11 ms conforming to IEC 60068-2-27
Noise level57.4 dB conforming to 86/188/EEC
Relative humidity5…95 % without condensation conforming to IEC 60068-2-3; 5…95 % without dripping water conforming to IEC 60068-2-3
Ambient air temperature for operation-10…50 °C (without derating)
Operating altitude<= 1000 m without derating; 1000...3000 m with current derating 1 % per 100 m
Operating positionVertical +/- 10 degree
Product certificationsUL; GOST; NOM 117; C-Tick; CSA
MarkingCE
StandardsUL Type 1; IEC 61800-3 environments 2 category C3; IEC 61800-3; EN 55011 class A group 2; IEC 60721-3-3 class 3C1; IEC 60721-3-3 class 3S2; IEC 61800-3 environments 1 category C3; IEC 61800-5-1
Assembly styleWith heat sink
Electromagnetic compatibilityElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Regulation loopAdjustable PI regulator
Speed accuracy+/- 0.01 % of nominal speed in closed-loop mode with encoder feedback 0.2 Tn to Tn; +/- 10 % of nominal slip without speed feedback 0.2 Tn to Tn
Ambient air temperature for storage-25…70 °C

Downloads & documentation

Official documents from Schneider Electric, downloaded directly from the manufacturer.

Data sheets & manuals

Product data sheet ATV71LD27N4ZPDF
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Schneider Electric parts

variable speed drive ATV71 - 18.5kW-25HP - 480V -EMC filter-w/o graphic terminalAvailable on requestvariable speed drive ATV71 - 18.5kW-25HP - 480V -EMC filter-w/o graphic terminal
MPN: ATV71LD18N4Z · Schneider Electric
Price on request
Request a quote
variable speed drive ATV71 - 22kW-30HP- 240V-w/o EMC filter-w/o graphic terminalAvailable on requestvariable speed drive ATV71 - 22kW-30HP- 240V-w/o EMC filter-w/o graphic terminal
MPN: ATV71LD22M3XZ · Schneider Electric
Price on request
Request a quote
variable speed drive ATV71 - 22kW-30HP - 480V - EMC filter-w/o graphic terminalAvailable on requestvariable speed drive ATV71 - 22kW-30HP - 480V - EMC filter-w/o graphic terminal
MPN: ATV71LD22N4Z · Schneider Electric
Price on request
Request a quote
variable speed drive Altivar Lift, 5.5 kW 7.5 Hp, 200...240 V three-phase, with heat sinkAvailable on requestvariable speed drive Altivar Lift, 5.5 kW 7.5 Hp, 200...240 V three-phase, with heat sink
MPN: ATV71LD27M3Z · Schneider Electric
Price on request
Request a quote
variable speed drive ATV71 - 30kW-40HP- 240V-w/o EMC filter-w/o graphic terminalAvailable on requestvariable speed drive ATV71 - 30kW-40HP- 240V-w/o EMC filter-w/o graphic terminal
MPN: ATV71LD30M3XZ · Schneider Electric
Price on request
Request a quote
variable speed drive ATV71 - 30kW-40HP - 480V - EMC filter-w/o graphic terminalAvailable on requestvariable speed drive ATV71 - 30kW-40HP - 480V - EMC filter-w/o graphic terminal
MPN: ATV71LD30N4Z · Schneider Electric
Price on request
Request a quote
variable speed drive Altivar Lift, 7.5 kW 10Hp, 200...240 V three-phase, with heat sinkAvailable on requestvariable speed drive Altivar Lift, 7.5 kW 10Hp, 200...240 V three-phase, with heat sink
MPN: ATV71LD33M3Z · Schneider Electric
Price on request
Request a quote