Schneider Electric ATV71LD33N4Z – variable speed drive Altivar Lift, 15 kW 20 Hp, 380...480 V three-phase, EMC filter, with heat sink
Discontinued by Schneider Electric — we can still source the original ATV71LD33N4Z (new, used or refurbished, subject to availability). Request a quote below.
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Altivar 71 |
| Lifecycle | Discontinued |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| UPC / EAN | 3606480326271 |
| Datasheet | Manufacturer datasheet ↗ |
Shipping & availability
Can I still buy the ATV71LD33N4Z now that it is discontinued?
Yes. Schneider Electric has discontinued the ATV71LD33N4Z, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time.
When can ATV71LD33N4Z be shipped?
ATV71LD33N4Z is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up ATV71LD33N4Z in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for ATV71LD33N4Z and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for ATV71LD33N4Z, subject to availability and destination.
This Altivar Lift variable speed drive can feed 3-phase asynchronous and asynchronous motors (with or without encoder). It is designed with heatsink and it has a built-in EMC filter. It works at a rated supply voltage from 380V to 480V AC. This drive has been specially designed with and for professionals. It features advanced functions like half-floor control, inspection mode, rollback management, direct to floor, evacuation with UPS, load measurement, deferred thermal stop. It is suitable for motors with power rating up to 15 kW / 20 hp. Its dimensions are, 230mm wide, 400mm high, 187mm deep. This drive provides precision and durability for your lift applications. It complies with lift standards EN 12015 and EN 12016 without external filter. Accessories like remote graphic display terminal, simple loader tool and options like encoder interface cards, I/O cards are available with Altivar Lift drives. Discontinued by Schneider Electric. PartnerPLC sources discontinued and surplus Schneider Electric automation parts — request a quote for price, condition and lead time.
Specifications
Main
| Device short name | ATV71 |
| Product destination | Asynchronous motors; Synchronous motors |
| Network number of phases | 3 phases |
| Supply voltage limits | 323…528 V |
| Supply frequency | 50...60 Hz - 5...5 % |
| Motor power kW | 15 kW, 3 phases at 380...480 V |
| Motor power hp | 20 hp, 3 phases at 380...480 V |
| Line current | 48 A for 380 V 3 phases 15 kW / 20 hp; 39 A for 480 V 3 phases 15 kW / 20 hp |
| Range of product | Altivar Lift |
| Product or component type | Variable speed drive |
| Product specific application | Lift |
| Variant | With integrated 7-segment display terminal |
| Communication port protocol | Modbus; CANopen |
| [Us] rated supply voltage | 380...480 V - 15...10 % |
| EMC filter | Integrated |
Complementary
| Apparent power | 31.6 kVA at 380 V 3 phases 15 kW / 20 hp |
| Prospective line Isc | 22 kA for 3 phases |
| Nominal output current | 33 A at 4 kHz 380 V 3 phases 15 kW / 20 hp; 27 A at 4 kHz 460 V 3 phases 15 kW / 20 hp |
| Maximum transient current | 44.9 A for 2 s 3 phases / 15 kW / 20 hp |
| Speed drive output frequency | 0…599 Hz |
| Speed range | 1…100 for asynchronous motor in open-loop mode, without speed feedback; 1…50 for synchronous motor in open-loop mode, without speed feedback; 1…1000 for asynchronous motor in closed-loop mode with encoder feedback |
| Torque accuracy | +/- 5 % in closed-loop mode with encoder feedback; +/- 15 % in open-loop mode, without speed feedback |
| Transient overtorque | 170 %, +/- 10 % for 60 s; 220 %, +/- 10 % for 2 s |
| Braking torque | 30 % without braking resistor; <= 150 % with braking or hoist resistor |
| Local signalling | 1 LED (red) for drive voltage |
| Output voltage | <= power supply voltage |
| Insulation | Electrical between power and control |
| type of cable for external connection | Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR; Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC; With an IP21 or an IP31 kit: 3 wire(s)IEC cable at 40 °C, copper 70 °C / PVC; With a NEMA Type1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC |
| Electrical connection | Terminal, clamping capacity: 2.5 mm², 14 AWG (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR); Terminal, clamping capacity: 35 mm², 2 AWG (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB) |
| Tightening torque | 5.4 N.m, 47.7 lb.in (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB); 0.6 N.m (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR) |
| Supply | Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 A, protection type: overload and short-circuit protection; Internal supply: 24 V DC (21…27 V), <200 A, protection type: overload and short-circuit protection |
| Sampling duration | 2 ms +/- 0.5 ms (LI6)if configured as logic input - discrete input(s); 2 ms +/- 0.5 ms (LI1...LI5) - discrete input(s); 2 ms +/- 0.5 ms (AI1-/Al1+) - analog input(s); 2 ms +/- 0.5 ms (Al2) - analog input(s) |
| Response time | R1A, R1B, R1C 7 ms, tolerance +/- 0.5 ms for discrete output(s); R2A, R2B 7 ms, tolerance +/- 0.5 ms for discrete output(s); AO1 2 ms, tolerance +/- 0.5 ms for analog output(s); <= 100 ms in STO (Safe Torque Off) |
| Accuracy | +/- 0.6 % (AI1-/Al1+) for a temperature variation 60 °C; +/- 0.6 % (AI2) for a temperature variation 60 °C; +/- 1 % (AO1) for a temperature variation 60 °C |
| Linearity error | +/- 0.15 % of maximum value (AI1-/Al1+, AI2); +/- 0.2 % (AO1) |
| Analogue output type | AO1 software-configurable voltage: 0...10 V DC, impedance: 470 Ohm, resolution 10 bits; AO1 software-configurable current: 0...20 mA, impedance: 500 Ohm, resolution 10 bits; AO1 software-configurable logic output 10 V 20 A |
| Discrete output type | Configurable relay logic: (R1A, R1B, R1C) NO/NC - 100000 cycles; Configurable relay logic: (R2A, R2B) NO - 100000 cycles |
| Minimum switching current | 3 mA at 24 V DC for configurable relay logic |
| Maximum switching current | 5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (R1, R2); 5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (R1, R2); 2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (R1, R2); 2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (R1, R2) |
| Discrete input type | Programmable (LI1...LI5)24 V DC, with level 1 PLC - 3500 Ohm; Switch-configurable (LI6)24 V DC, with level 1 PLC - 3500 Ohm; Switch-configurable PTC probe (LI6) - 0…6 probes - 1500 Ohm; Safety input (PWR)24 V DC - 1500 Ohm |
| Discrete input logic | Positive logic (LI6)if configured as logic input, < 5 V (state 0), > 11 V (state 1); Negative logic (LI6)if configured as logic input, > 16 V (state 0), < 10 V (state 1); Positive logic (LI1...LI5), < 5 V (state 0), > 11 V (state 1); Negative logic (LI1...LI5), > 16 V (state 0), < 10 V (state 1); Positive logic (PWR), < 2 V (state 0), > 17 V (state 1) |
| Dielectric strength | 3535 V DC between earth and power terminals; 5092 V DC between control and power terminals |
| Insulation resistance | > 1 mOhm 500 V DC for 1 minute to earth |
| Frequency resolution | Display unit: 0.1 Hz; Analog input: 0.024/50 Hz |
| Connector type | 1 RJ45 (on front face) for Modbus; 1 RJ45 (on terminal) for Modbus; Male SUB-D 9 on RJ45 for CANopen |
| Physical interface | 2-wire RS 485 for Modbus |
| Transmission frame | RTU for Modbus |
| Transmission rate | 9600 bps, 19200 bps for Modbus on front face; 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal; 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen |
| Data format | 8 bits, 1 stop, even parity for Modbus on front face; 8 bits, odd even or no configurable parity for Modbus on terminal |
| Type of polarization | No impedance for Modbus |
| Number of addresses | 1…247 for Modbus; 1…127 for CANopen |
| control options | Communication card for Modbus TCP; Communication card for Fipio; Communication card for Modbus/Uni-Telway; Communication card for Modbus Plus; Communication card for EtherNet/IP; Communication card for DeviceNet; Communication card for Profibus DP; Communication card for Profibus DP V1; Communication card for Interbus-S; Communication card for CC-Link; Interface card for encoder; I/O extension card; Controller inside programmable card; Overhead crane card |
| Discrete input number | 7 |
| Discrete output number | 2 |
| Analogue input number | 2 |
| Analogue input type | AI2 software-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 11 bits; AI1-/Al1+ bipolar differential voltage: +/- 10 V DC 24 V max, resolution 11 bits + sign; AI2 software-configurable current: 0...20 mA, impedance: 242 Ohm, resolution 11 bits |
| Analogue output number | 1 |
| Method of access | Slave CANopen |
| Asynchronous motor control profile | Voltage/frequency ratio - Energy Saving, quadratic U/f; Flux vector control without sensor, standard; Flux vector control without sensor, ENA (energy Adaptation) system; Voltage/frequency ratio, 5 points; Flux vector control with sensor, standard; Voltage/frequency ratio, 2 points; Flux vector control without sensor, 2 points |
| Synchronous motor control profile | Vector control without sensor, standard; Vector control with sensor, standard |
| Acceleration and deceleration ramps | S, U or customized; Linear adjustable separately from 0.01 to 9000 s; Automatic adaptation of ramp if braking capacity exceeded, by using resistor |
| Motor slip compensation | Automatic whatever the load; Not available in voltage/frequency ratio (2 or 5 points); Suppressable; Adjustable |
| Switching frequency | 1...16 kHz adjustable |
| Nominal switching frequency | 8 kHz |
| Minimum braking resistance | 7 Ohm |
| Network frequency | 47.5...63 Hz |
| Protection type | Overheating protection: drive; Thermal protection: drive; Short-circuit between motor phases: drive; Input phase breaks: drive; Overcurrent between output phases and earth: drive; Overvoltages on the DC bus: drive; Break on the control circuit: drive; Against exceeding limit speed: drive; Line supply undervoltage: drive; Line supply overvoltage: drive; Against input phase loss: drive; Thermal protection: motor; Motor phase break: motor; Power removal: motor |
Environment
| Pollution degree | 2 conforming to IEC 61800-5-1 |
| IP degree of protection | IP20 on upper part without blanking plate on cover conforming to IEC 61800-5-1; IP20 on upper part without blanking plate on cover conforming to IEC 60529; IP21 conforming to IEC 61800-5-1; IP21 conforming to IEC 60529; IP41 on upper part conforming to IEC 61800-5-1; IP41 on upper part conforming to IEC 60529; IP54 on lower part conforming to IEC 61800-5-1; IP54 on lower part conforming to IEC 60529 |
| Vibration resistance | 1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6; 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6 |
| Shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
| Noise level | 60.2 dB conforming to 86/188/EEC |
| Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3; 5…95 % without dripping water conforming to IEC 60068-2-3 |
| Ambient air temperature for operation | -10…50 °C (without derating) |
| Operating altitude | <= 1000 m without derating; 1000...3000 m with current derating 1 % per 100 m |
| Operating position | Vertical +/- 10 degree |
| Product certifications | C-Tick; CSA; GOST; UL; NOM 117 |
| Marking | CE |
| Standards | EN 55011 class A group 2; IEC 61800-3 environments 1 category C3; IEC 61800-5-1; IEC 61800-3 environments 2 category C3; IEC 60721-3-3 class 3C1; UL Type 1; IEC 60721-3-3 class 3S2; IEC 61800-3 |
| Assembly style | With heat sink |
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
| Regulation loop | Adjustable PI regulator |
| Speed accuracy | +/- 0.01 % of nominal speed in closed-loop mode with encoder feedback 0.2 Tn to Tn; +/- 10 % of nominal slip without speed feedback 0.2 Tn to Tn |
| Ambient air temperature for storage | -25…70 °C |
Downloads & documentation
Official documents from Schneider Electric, downloaded directly from the manufacturer.
Data sheets & manuals
| Product data sheet ATV71LD33N4Z |
More Schneider Electric parts
Available on requestvariable speed drive Altivar Lift, 11 kW 15 Hp, 380...480 V three-phase, EMC filter, with heat sink
Available on requestvariable speed drive ATV71 - 30kW-40HP- 240V-w/o EMC filter-w/o graphic terminal
Available on requestvariable speed drive ATV71 - 30kW-40HP - 480V - EMC filter-w/o graphic terminal
Available on requestvariable speed drive Altivar Lift, 7.5 kW 10Hp, 200...240 V three-phase, with heat sink
Available on requestvariable speed drive ATV71 - 37kW-50HP- 240V-w/o EMC filter-w/o graphic terminal
Available on requestvariable speed drive ATV71 - 37kW-50HP - 480V - EMC filter-w/o graphic terminal
Available on requestvariable speed drive ATV71 - 45kW-60HP- 240V-w/o EMC filter-w/o graphic terminal
Available on requestvariable speed drive Altivar Lift, 45 kW 60 Hp, 380...480 V three-phase, EMC filter, with heat sink