Quick facts
| Availability | Confirmed on request |
| Category | Altivar 71 |
| Lifecycle | Discontinued |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| UPC / EAN | 3606480326295 |
| Datasheet | Manufacturer datasheet ↗ |
Shipping & availability
Can I still buy the ATV71LD27M3Z now that it is discontinued?
Yes. Schneider Electric has discontinued the ATV71LD27M3Z, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time.
When can ATV71LD27M3Z be shipped?
ATV71LD27M3Z is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up ATV71LD27M3Z in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for ATV71LD27M3Z and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for ATV71LD27M3Z, subject to availability and destination.
Schneider Electric ATV71LD27M3Z — variable speed drive Altivar Lift, 5.5 kW 7.5 Hp, 200...240 V three-phase, with heat sink. Discontinued by Schneider Electric. PartnerPLC sources discontinued and surplus Schneider Electric automation parts — request a quote for price, condition and lead time.
Specifications
Main
| Device short name | ATV71 |
| Product destination | Synchronous motors; Asynchronous motors |
| Network number of phases | 3 phases |
| Supply voltage limits | 170…264 V |
| Supply frequency | 50...60 Hz - 5...5 % |
| Motor power kW | 5.5 kW, 3 phases at 200...240 V |
| Motor power hp | 7.5 hp, 3 phases at 200...240 V |
| Line current | 35 A for 200 V 3 phases 5.5 kW / 7.5 hp; 30.8 A for 240 V 3 phases 5.5 kW / 7.5 hp |
| Range of product | Altivar Lift |
| Product or component type | Variable speed drive |
| Product specific application | Lift |
| Variant | With integrated 7-segment display terminal |
| Communication port protocol | CANopen; Modbus |
| [Us] rated supply voltage | 200...240 V - 15...10 % |
Complementary
| Apparent power | 12.8 kVA at 240 V 3 phases 5.5 kW / 7.5 hp |
| Prospective line Isc | 22 kA for 3 phases |
| Nominal output current | 27.5 A at 4 kHz 230 V 3 phases 5.5 kW / 7.5 hp |
| Maximum transient current | 37.4 A for 2 s 3 phases / 5.5 kW / 7.5 hp |
| Speed drive output frequency | 0…599 Hz |
| Speed range | 1…100 for asynchronous motor in open-loop mode, without speed feedback; 1…50 for synchronous motor in open-loop mode, without speed feedback; 1…1000 for asynchronous motor in closed-loop mode with encoder feedback |
| Torque accuracy | +/- 5 % in closed-loop mode with encoder feedback; +/- 15 % in open-loop mode, without speed feedback |
| Transient overtorque | 170 %, +/- 10 % for 60 s; 220 %, +/- 10 % for 2 s |
| Braking torque | 30 % without braking resistor; <= 150 % with braking or hoist resistor |
| Local signalling | 1 LED (red) for drive voltage |
| Output voltage | <= power supply voltage |
| Insulation | Electrical between power and control |
| type of cable for external connection | Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR; Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC; With an IP21 or an IP31 kit: 3 wire(s)IEC cable at 40 °C, copper 70 °C / PVC; With a NEMA Type1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC |
| Electrical connection | Terminal, clamping capacity: 2.5 mm², 14 AWG (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR); Terminal, clamping capacity: 6 mm², 8 AWG (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB) |
| Tightening torque | 3 N.m, 26.5 lb.in (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB); 0.6 N.m (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR) |
| Supply | Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 A, protection type: overload and short-circuit protection; Internal supply: 24 V DC (21…27 V), <200 A, protection type: overload and short-circuit protection |
| Sampling duration | 2 ms +/- 0.5 ms (LI6)if configured as logic input - discrete input(s); 2 ms +/- 0.5 ms (LI1...LI5) - discrete input(s); 2 ms +/- 0.5 ms (AI1-/Al1+) - analog input(s); 2 ms +/- 0.5 ms (Al2) - analog input(s) |
| Response time | R1A, R1B, R1C 7 ms, tolerance +/- 0.5 ms for discrete output(s); R2A, R2B 7 ms, tolerance +/- 0.5 ms for discrete output(s); AO1 2 ms, tolerance +/- 0.5 ms for analog output(s); <= 100 ms in STO (Safe Torque Off) |
| Accuracy | +/- 0.6 % (AI1-/Al1+) for a temperature variation 60 °C; +/- 0.6 % (AI2) for a temperature variation 60 °C; +/- 1 % (AO1) for a temperature variation 60 °C |
| Linearity error | +/- 0.15 % of maximum value (AI1-/Al1+, AI2); +/- 0.2 % (AO1) |
| Analogue output type | AO1 software-configurable voltage: 0...10 V DC, impedance: 470 Ohm, resolution 10 bits; AO1 software-configurable current: 0...20 mA, impedance: 500 Ohm, resolution 10 bits; AO1 software-configurable logic output 10 V 20 A |
| Discrete output type | Configurable relay logic: (R1A, R1B, R1C) NO/NC - 100000 cycles; Configurable relay logic: (R2A, R2B) NO - 100000 cycles |
| Minimum switching current | 3 mA at 24 V DC for configurable relay logic |
| Maximum switching current | 5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (R1, R2); 5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (R1, R2); 2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (R1, R2); 2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (R1, R2) |
| Discrete input type | Programmable (LI1...LI5)24 V DC, with level 1 PLC - 3500 Ohm; Switch-configurable (LI6)24 V DC, with level 1 PLC - 3500 Ohm; Switch-configurable PTC probe (LI6) - 0…6 probes - 1500 Ohm; Safety input (PWR)24 V DC - 1500 Ohm |
| Discrete input logic | Positive logic (LI6)if configured as logic input, < 5 V (state 0), > 11 V (state 1); Negative logic (LI6)if configured as logic input, > 16 V (state 0), < 10 V (state 1); Positive logic (LI1...LI5), < 5 V (state 0), > 11 V (state 1); Negative logic (LI1...LI5), > 16 V (state 0), < 10 V (state 1); Positive logic (PWR), < 2 V (state 0), > 17 V (state 1) |
| Dielectric strength | 2830 V DC between earth and power terminals; 4230 V DC between control and power terminals |
| Insulation resistance | > 1 mOhm 500 V DC for 1 minute to earth |
| Frequency resolution | Display unit: 0.1 Hz; Analog input: 0.024/50 Hz |
| Connector type | 1 RJ45 (on front face) for Modbus; 1 RJ45 (on terminal) for Modbus; Male SUB-D 9 on RJ45 for CANopen |
| Physical interface | 2-wire RS 485 for Modbus |
| Transmission frame | RTU for Modbus |
| Transmission rate | 9600 bps, 19200 bps for Modbus on front face; 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal; 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen |
| Data format | 8 bits, 1 stop, even parity for Modbus on front face; 8 bits, odd even or no configurable parity for Modbus on terminal |
| Type of polarization | No impedance for Modbus |
| Number of addresses | 1…247 for Modbus; 1…127 for CANopen |
| control options | Communication card for Modbus TCP; Communication card for Fipio; Communication card for Modbus/Uni-Telway; Communication card for Modbus Plus; Communication card for EtherNet/IP; Communication card for DeviceNet; Communication card for Profibus DP; Communication card for Profibus DP V1; Communication card for Interbus-S; Communication card for CC-Link; Interface card for encoder; I/O extension card; Controller inside programmable card; Overhead crane card |
| Discrete input number | 7 |
| Discrete output number | 2 |
| Analogue input number | 2 |
| Analogue input type | AI2 software-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 11 bits; AI1-/Al1+ bipolar differential voltage: +/- 10 V DC 24 V max, resolution 11 bits + sign; AI2 software-configurable current: 0...20 mA, impedance: 242 Ohm, resolution 11 bits |
| Analogue output number | 1 |
| Method of access | Slave CANopen |
| Asynchronous motor control profile | Voltage/frequency ratio, 5 points; Voltage/frequency ratio - Energy Saving, quadratic U/f; Flux vector control without sensor, 2 points; Flux vector control with sensor, standard; Flux vector control without sensor, standard; Flux vector control without sensor, ENA (energy Adaptation) system; Voltage/frequency ratio, 2 points |
| Synchronous motor control profile | Vector control without sensor, standard; Vector control with sensor, standard |
| Acceleration and deceleration ramps | S, U or customized; Linear adjustable separately from 0.01 to 9000 s; Automatic adaptation of ramp if braking capacity exceeded, by using resistor |
| Motor slip compensation | Adjustable; Automatic whatever the load; Suppressable; Not available in voltage/frequency ratio (2 or 5 points) |
| Switching frequency | 1...16 kHz adjustable |
| Nominal switching frequency | 8 kHz |
| Network frequency | 47.5...63 Hz |
| Protection type | Overheating protection: drive; Thermal protection: drive; Short-circuit between motor phases: drive; Input phase breaks: drive; Overcurrent between output phases and earth: drive; Overvoltages on the DC bus: drive; Break on the control circuit: drive; Against exceeding limit speed: drive; Line supply undervoltage: drive; Line supply overvoltage: drive; Against input phase loss: drive; Thermal protection: motor; Motor phase break: motor; Power removal: motor |
Environment
| Pollution degree | 2 conforming to EN/IEC 61800-5-1 |
| IP degree of protection | IP20 on upper part without blanking plate on cover conforming to EN/IEC 61800-5-1; IP20 on upper part without blanking plate on cover conforming to EN/IEC 60529; IP21 conforming to EN/IEC 61800-5-1; IP21 conforming to EN/IEC 60529; IP41 on upper part conforming to EN/IEC 61800-5-1; IP41 on upper part conforming to EN/IEC 60529; IP54 on lower part conforming to EN/IEC 61800-5-1; IP54 on lower part conforming to EN/IEC 60529 |
| Vibration resistance | 1.5 mm peak to peak (f= 3…13 Hz) conforming to EN/IEC 60068-2-6; 1 gn (f= 13…200 Hz) conforming to EN/IEC 60068-2-6 |
| Shock resistance | 15 gn for 11 ms conforming to EN/IEC 60068-2-27 |
| Noise level | 55.6 dB conforming to 86/188/EEC |
| Relative humidity | 5…95 % without condensation conforming to IEC 60068-2-3; 5…95 % without dripping water conforming to IEC 60068-2-3 |
| Ambient air temperature for operation | -10…50 °C (without derating) |
| Operating altitude | <= 1000 m without derating; 1000...3000 m with current derating 1 % per 100 m |
| Operating position | Vertical +/- 10 degree |
| Product certifications | CSA; UL; NOM 117; GOST; C-Tick |
| Marking | CE |
| Standards | EN 61800-3 environments 2 category C3; EN/IEC 61800-5-1; IEC 60721-3-3 class 3C1; EN/IEC 61800-3; EN 61800-3 environments 1 category C3; UL Type 1; EN 55011 class A group 2; IEC 60721-3-3 class 3S2 |
| Assembly style | With heat sink |
| Electromagnetic compatibility | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
| Regulation loop | Adjustable PI regulator |
| Speed accuracy | +/- 0.01 % of nominal speed in closed-loop mode with encoder feedback 0.2 Tn to Tn; +/- 10 % of nominal slip without speed feedback 0.2 Tn to Tn |
| Ambient air temperature for storage | -25…70 °C |
Downloads & documentation
Official documents from Schneider Electric, downloaded directly from the manufacturer.
Data sheets & manuals
| Product data sheet ATV71LD27M3Z |
More Schneider Electric parts
Available on requestvariable speed drive ATV71 -18.5kW-25HP- 240V-w/o EMCfilter-w/o graphic terminal
Available on requestvariable speed drive ATV71 - 18.5kW-25HP - 480V -EMC filter-w/o graphic terminal
Available on requestvariable speed drive ATV71 - 22kW-30HP - 480V - EMC filter-w/o graphic terminal
Available on requestvariable speed drive Altivar Lift, 11 kW 15 Hp, 380...480 V three-phase, EMC filter, with heat sink
Available on requestvariable speed drive ATV71 - 30kW-40HP - 480V - EMC filter-w/o graphic terminal