What is the Pepperl Fuchs VAA-4E4A-G11-ZAJ/EA2L-FV1?

Inputs for 2-, 3-, and 4-wire sensors

Power supply of outputs from the external auxiliary voltage

Supply of sensors from AS-Interface

Function display for bus, external auxiliary voltage, in- and outputs

Red LED per channel, lights up in the event of output overload

Communication monitoring

Switchable lead breakage detection (outputs)

Cable piercing method with gold plated contact pins

Degree of protection IP68 / IP69K

AS-Interface POWER24

G11 module, 4 inputs and 4 outputs

Specifications

General specifications

Order code (Pepperl+Fuchs part number)220224
Node typeStandard node
AS-Interface specificationV3.0
Required gateway specification≥ V2.1
ProfileS-7.F
IO code7
ID codeF
ID1 codeF
ID2 codeE
UL File NumberE223772
LifecycleActive (current Pepperl+Fuchs product)

Indicators/operating means

LED AS-i/FAULTStatus display; multi-colour LED Green: normal operation Red: communication fault Flashing yellow/red: address 0 Flashing green/red: sensor supply i.e. overload or lead interruption outputs
LED AUXext. auxiliary voltage UAUX; dual LED green/red green: voltage OK red: reverse voltage
LED INswitching state (input); 4 LED yellow
LED OUTswitching state (output); 4 LED yellow/red yellow: output active red: output overload or lead interruption

Electrical specifications

Auxiliary voltage (output)20 ... 30 V DC PELV UAUX
Rated operating voltage18,0 ... 31.6 V from AS-Interface Ue
Rated operating current≤ 40 mA (without sensors) / max. 240 mA Ie
Protection classIII
Surge protectionUAUX, Uin: Over voltage category III, safe isolated power supplies (PELV)

Input

Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC option 2 inputs for 4-wire sensors (PNP), DC
Supplyfrom AS-Interface
Voltage12 ... 31 V
Current loading capacity≤ 200 mA, overload and short-circuit protected
Input current≤ 9 mA (limited internally)
Switching pointaccording to DIN EN 61131-2 (Type 2)
0 (unattenuated)≤ 3 mA
1 (attenuated)≥ 5 mA
Signal delay< 1 ms (input/AS-Interface)

Output

Number/Type4 electronic outputs, PNP, overload and short-circuit proof
Supplyfrom external auxiliary voltage UAUX
Voltage≥ (UAUX - 0.5 V)
Current2 A per outputTB ≤ 40 °C: 6 A totalTB ≤ 70 °C: sum O1 + O2 max. 2 A, sum O3 + O4 max. 2 A

Galvanic isolation

Input/Outputsafe isolation, rated insulation voltage 40 V DC
Output/AS-Interfacesafe isolation, rated insulation voltage 40 V DC

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007

Standard conformity

Degree of protectionEN 60529:2000
Fieldbus standardEN 62026-2:2013
InputEN 61131-2:2007
Emitted interferenceEN 61000-6-4:2007
AS-InterfaceEN 62026-2:2013
Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013

Ambient conditions

Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Relative humidity85 % , non-condensing
Climatic conditionsFor indoor use only
Altitude≤ 2000 m above MSL
Shock and impact resistance30 g, 11 ms in 6 spatial directions 3 shocks 10 g, 16 ms in 6 spatial directions 1000 shocks
Vibration resistance0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles
Pollution degree3

Mechanical specifications

Degree of protectionIP68 / IP69K
ConnectionAS-Interface/UAUX: AS-Interface flat cable or M12 round connector Inputs/outputs: M12 round connector
Material: HousingPBT PC
Material: Mounting screwStainless steel 1.4305 / AISI 303
Mass200 g
Tightening torque, housing screws1.8 Nm
Tightening torque, cable gland0.4 Nm
Dimensions: Height46 mm
Dimensions: Diameter85 mm
MountingMounting plate

VAA-4E4A-G11-ZAJ/EA2L-FV1: frequently asked questions

When can VAA-4E4A-G11-ZAJ/EA2L-FV1 be shipped?

VAA-4E4A-G11-ZAJ/EA2L-FV1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up VAA-4E4A-G11-ZAJ/EA2L-FV1 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for VAA-4E4A-G11-ZAJ/EA2L-FV1 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VAA-4E4A-G11-ZAJ/EA2L-FV1, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs VAA-4E4A-CB2-Z/E2 – AS-Interface printed circuit board module
Pepperl Fuchs
VAA-4E4A-CB2-Z/E2

AS-Interface printed circuit board module

Pepperl Fuchs VAA-4E4A-G11-ZAJ/EA2L-FV1Price and lead time confirmed within 1 business day
Request a Quote