Pepperl Fuchs VAA-4E4A-CB2-Z/E2
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Modules |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can VAA-4E4A-CB2-Z/E2 be shipped?
VAA-4E4A-CB2-Z/E2 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up VAA-4E4A-CB2-Z/E2 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for VAA-4E4A-CB2-Z/E2 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VAA-4E4A-CB2-Z/E2, subject to availability and destination.
AS-Interface printed circuit board module. Printed circuit board module, encapsulated in housing, 4 inputs/4 outputs. Node type: Standard node. AS-Interface specification: V2.0. Required gateway specification: ≥ V2.0. UL File Number: E223772. LED FAULT: error display; LED redred: communication error or address is 0red flashing: overload of outputs. LED PWR: AS-Interface voltage; LED green. LED AUX: ext. auxiliary voltage UAUX ; LED green. LED IN: switching state (input); 4 LED yellow. LED OUT: Switching state (output); 4 LED yellow. Rated operating voltage: 26.5 ... 31.6 V from AS-Interface. Rated operating current: ≤ 30 mA. Protection class: III. Surge protection: UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV). Number/Type: 4 inputs for 2- or 3-wire sensors (PNP), DC. Supply: from external auxiliary voltage UAUX. Voltage: 20 ... 30 V DC PELV. Input current: 5 mA (typically). Switching point: according to EN 61131-2 Typ 1. 0 (unattenuated)≤ 0.5 mA1 (attenuated)≥ 2 mA: . 0 (unattenuated): ≤ 0.5 mA. 1 (attenuated): ≥ 2 mA. Signal delay: < 2 ms (input/AS-Interface). Signal frequency: ≤ 250 Hz. Number/Type: 4 electronic outputs, PNP. Supply: from external auxiliary voltage UAUX. Voltage: 20 ... 30 V DC PELV. Current: ≤ 100 mA per output, ≤ 140 mA total. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013 EN 61000-6-4:2007 EN 62026-2:2015: . Directive 2014/30/EU: EN 61326-1:2013 EN 61000-6-4:2007 EN 62026-2:2015. Degree of protection: EN 60529:2000. Fieldbus standard: EN 62026-2:2013. Input: EN 61131-2:2015. Emitted interference: EN 61000-6-4:2007. AS-Interface: EN 62026-2:2013. Noise immunity: EN 61326-1:2013. Profile: S-7.0. IO code: 7. ID code: 0. ID1 code: F. ID2 code: E. Data bits (function via AS-Interface): InputOutput. D0 IN1 OUT1D1 IN2 OUT2D2 IN3 OUT3D3 IN4 OUT4: . D0: IN1 OUT1. D1: IN2 OUT2. D2: IN3 OUT3. D3: IN4 OUT4. Parameter bits (programmable via AS-i): function. P0not usedP1not usedP2not usedP3not used: . P0: not used. P1: not used. P2: not used. P3: not used. Ambient temperature: -25 ... 60 °C (-13 ... 140 °F). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: 85 % , noncondensing. Climatic conditions: For indoor use only. Altitude: ≤ 2000 m above MSL. Pollution degree: 2. Connection: screw terminals, removable rated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 1.5 mm2In case of wire end ferrule with plastic sleeve: 0.25 mm2 ... 0.5 mm2On connection of multiple conductors when using two conductors with the same cross section:Flexible with twin wire end ferrule:. Mass: 90 g. Dimensions: . Height29 mmWidth51 mmLength76 mm: . Height: 29 mm. Width: 51 mm. Length: 76 mm. Mounting: Self-adhesive velcro for mounting enclosed. Tightening torque of clamping screws: 0.22 ... 0.25 Nm
Specifications
General specifications
| Node type | Standard node |
| AS-Interface specification | V2.0 |
| Required gateway specification | ≥ V2.0 |
| UL File Number | E223772 |
Indicators/operating means
| LED FAULT | error display; LED redred: communication error or address is 0red flashing: overload of outputs |
| LED PWR | AS-Interface voltage; LED green |
| LED AUX | ext. auxiliary voltage UAUX ; LED green |
| LED IN | switching state (input); 4 LED yellow |
| LED OUT | Switching state (output); 4 LED yellow |
Electrical specifications
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface Ue |
| Rated operating current | ≤ 30 mA Ie |
| Protection class | III |
| Surge protection | UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) |
Input
| Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC |
| Supply | from external auxiliary voltage UAUX |
| Voltage | 20 ... 30 V DC PELV |
| Input current | 5 mA (typically) |
| Switching point | according to EN 61131-2 Typ 1 |
| 0 (unattenuated)≤ 0.5 mA1 (attenuated)≥ 2 mA | 0 (unattenuated) |
| 0 (unattenuated) | ≤ 0.5 mA |
| 1 (attenuated) | ≥ 2 mA |
| Signal delay | < 2 ms (input/AS-Interface) |
| Signal frequency | ≤ 250 Hz |
Output
| Number/Type | 4 electronic outputs, PNP |
| Supply | from external auxiliary voltage UAUX |
| Voltage | 20 ... 30 V DC PELV |
| Current | ≤ 100 mA per output, ≤ 140 mA total |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 EN 61000-6-4:2007 EN 62026-2:2015 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 EN 61000-6-4:2007 EN 62026-2:2015 |
Standard conformity
| Degree of protection | EN 60529:2000 |
| Fieldbus standard | EN 62026-2:2013 |
| Input | EN 61131-2:2015 |
| Emitted interference | EN 61000-6-4:2007 |
| AS-Interface | EN 62026-2:2013 |
| Noise immunity | EN 61326-1:2013 |
Programming instructions
| Profile | S-7.0 |
| IO code | 7 |
| ID code | 0 |
| ID1 code | F |
| ID2 code | E |
| Data bits (function via AS-Interface) | InputOutput |
| D0 IN1 OUT1D1 IN2 OUT2D2 IN3 OUT3D3 IN4 OUT4 | D0 |
| D0 | IN1 OUT1 |
| D1 | IN2 OUT2 |
| D2 | IN3 OUT3 |
| D3 | IN4 OUT4 |
| Parameter bits (programmable via AS-i) | function |
| P0not usedP1not usedP2not usedP3not used | P0 |
| P0 | not used |
| P1 | not used |
| P2 | not used |
| P3 | not used |
Ambient conditions
| Ambient temperature | -25 ... 60 °C (-13 ... 140 °F) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity | 85 % , noncondensing |
| Climatic conditions | For indoor use only |
| Altitude | ≤ 2000 m above MSL |
| Pollution degree | 2 |
Mechanical specifications
| Connection | screw terminals, removable rated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 1.5 mm2In case of wire end ferrule with plastic sleeve: 0.25 mm2 ... 0.5 mm2On connection of multiple conductors when using two conductors with the same cross section:Flexible with twin wire end ferrule: |
| Mass | 90 g |
| Dimensions | |
| Height29 mmWidth51 mmLength76 mm | Height |
| Height | 29 mm |
| Width | 51 mm |
| Length | 76 mm |
| Mounting | Self-adhesive velcro for mounting enclosed |
| Tightening torque of clamping screws | 0.22 ... 0.25 Nm |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
Available on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G