Pepperl Fuchs VAA-4E4A-G11-ZAJ/EA2L-F
AS-Interface sensor/actuator module
- MPN
- VAA-4E4A-G11-ZAJ/EA2L-F
- Category
- Modules
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Pepperl Fuchs VAA-4E4A-G11-ZAJ/EA2L-F?
Inputs for 2-, 3-, and 4-wire sensors
Power supply of outputs from the external auxiliary voltage
Supply of sensors from AS-Interface
Function display for bus, external auxiliary voltage, in- and outputs
Red LED per channel, lights up in the event of output overload
Communication monitoring
Switchable lead breakage detection (outputs)
Cable piercing method with gold plated contact pins
Degree of protection IP68 / IP69K
AS-Interface POWER24
G11 module, 4 inputs and 4 outputs
Specifications
General specifications
| Order code (Pepperl+Fuchs part number) | 220205 |
| Node type | Standard node |
| AS-Interface specification | V3.0 |
| Required gateway specification | ≥ V2.1 |
| Profile | S-7.F |
| IO code | 7 |
| ID code | F |
| ID1 code | F |
| ID2 code | E |
| UL File Number | E223772 |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Indicators/operating means
| LED AS-i/FAULT | Status display; multi-colour LED Green: normal operation Red: communication fault Flashing yellow/red: address 0 Flashing green/red: sensor supply i.e. overload or lead interruption outputs |
| LED AUX | ext. auxiliary voltage UAUX; dual LED green/red green: voltage OK red: reverse voltage |
| LED IN | switching state (input); 4 LED yellow |
| LED OUT | switching state (output); 4 LED yellow/red yellow: output active red: output overload or lead interruption |
Electrical specifications
| Auxiliary voltage (output) | 20 ... 30 V DC PELV UAUX |
| Rated operating voltage | 18,0 ... 31.6 V from AS-Interface Ue |
| Rated operating current | ≤ 40 mA (without sensors) / max. 240 mA Ie |
| Protection class | III |
| Surge protection | UAUX, Uin: Over voltage category III, safe isolated power supplies (PELV) |
Input
| Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC option 2 inputs for 4-wire sensors (PNP), DC |
| Supply | from AS-Interface |
| Voltage | 12 ... 31 V |
| Current loading capacity | ≤ 200 mA, overload and short-circuit protected |
| Input current | ≤ 9 mA (limited internally) |
| Switching point | according to DIN EN 61131-2 (Type 2) |
| 0 (unattenuated) | ≤ 3 mA |
| 1 (attenuated) | ≥ 5 mA |
| Signal delay | < 1 ms (input/AS-Interface) |
Output
| Number/Type | 4 electronic outputs, PNP, overload and short-circuit proof |
| Supply | from external auxiliary voltage UAUX |
| Voltage | ≥ (UAUX - 0.5 V) |
| Current | 2 A per outputTB ≤ 40 °C: 6 A totalTB ≤ 70 °C: sum O1 + O2 max. 2 A, sum O3 + O4 max. 2 A |
Galvanic isolation
| Input/Output | safe isolation, rated insulation voltage 40 V DC |
| Output/AS-Interface | safe isolation, rated insulation voltage 40 V DC |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 |
Standard conformity
| Degree of protection | EN 60529:2000 |
| Fieldbus standard | EN 62026-2:2013 |
| Input | EN 61131-2:2007 |
| Emitted interference | EN 61000-6-4:2007 |
| AS-Interface | EN 62026-2:2013 |
| Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 |
Ambient conditions
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 85 % , non-condensing |
| Climatic conditions | For indoor use only |
| Altitude | ≤ 2000 m above MSL |
| Shock and impact resistance | 30 g, 11 ms in 6 spatial directions 3 shocks 10 g, 16 ms in 6 spatial directions 1000 shocks |
| Vibration resistance | 0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles |
| Pollution degree | 3 |
Mechanical specifications
| Degree of protection | IP68 / IP69K |
| Connection | AS-Interface/UAUX: AS-Interface flat cable Inputs/outputs: M12 round connector |
| Material: Housing | PBT PC |
| Material: Mounting screw | Stainless steel 1.4305 / AISI 303 |
| Mass | 200 g |
| Tightening torque, housing screws | 1.8 Nm |
| Tightening torque, cable gland | 0.4 Nm |
| Dimensions: Height | 35 mm |
| Dimensions: Diameter | 85 mm |
| Mounting | Mounting plate |
No matching specifications
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
VAA-4E4A-G11-ZAJ/EA2L-F: frequently asked questions
When can VAA-4E4A-G11-ZAJ/EA2L-F be shipped?
VAA-4E4A-G11-ZAJ/EA2L-F is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up VAA-4E4A-G11-ZAJ/EA2L-F in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for VAA-4E4A-G11-ZAJ/EA2L-F and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VAA-4E4A-G11-ZAJ/EA2L-F, subject to availability and destination.
More Pepperl Fuchs parts