Pepperl Fuchs LB9023BP08110.0.E
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | LB (Zone 2, Class I/Div. 2) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can LB9023BP08110.0.E be shipped?
LB9023BP08110.0.E is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up LB9023BP08110.0.E in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for LB9023BP08110.0.E and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LB9023BP08110.0.E, subject to availability and destination.
Base Backplane. Backplane for LB-System, For MODBUS TCP/IP, Max. 8 slots for I/O modules, Mounting in Zone 2, Class I/Div.2 or in the safe area, Number of modules: 8, Fieldbus type: MODBUS TCP. Suitable components: Extension Backplane LB9025BP08100.1 Bus Coupler LB8111A*. Bus coupler: 1. Supply: 1. I/O modules (single width): max. 8. I/O modules (dual width): max. 4. Maximum safe voltage Um: 60 V DC (SELV/PELV). Input voltage range: 18 ... 32 V DC (SELV/PELV). Redundancy: no. Fieldbus type: MODBUS TCP. Redundancy: no. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Electromagnetic compatibility: NE 21. Degree of protection: EN 60529. Ambient temperature: -40 ... 60 °C (-40 ... 140 °F) , 70 °C (non-Ex). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: 95 % non-condensing. Altitude: max. 2000 m. Shock resistance: shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18. Vibration resistance: frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance. Damaging gas: designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3. Degree of protection: IP20. Mass: approx. 1010 g. Dimensions: (W x H x D) 275 x 127 x 80 mm (10.8 x 5 x 3.15 inch) , without modules. Height127 mmWidth275 mmDepth80 mm: . Height: 127 mm. Width: 275 mm. Depth: 80 mm. Certificate: BVS 16 ATEX E 089 X. Marking II 3 G Ex nA IIC T4 Gc: . Marking: II 3 G Ex nA IIC T4 Gc. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-15:2010: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 EN 60079-15:2010. UL approval: E106378. Control drawing116-0321: . Control drawing: 116-0321. IECEx approval: BVS 09.0037X. Approved forEx nA IIC T4 Gc: . Approved for: Ex nA IIC T4 Gc. Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Suitable components | Extension Backplane LB9025BP08100.1 Bus Coupler LB8111A* |
Slots
| Bus coupler | 1 |
| Supply | 1 |
| I/O modules (single width) | max. 8 |
| I/O modules (dual width) | max. 4 |
Supply
| Maximum safe voltage Um | 60 V DC (SELV/PELV) |
| Input voltage range | 18 ... 32 V DC (SELV/PELV) U |
| Redundancy | no |
Fieldbus connection
| Fieldbus type | MODBUS TCP |
| Redundancy | no |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 |
Conformity
| Electromagnetic compatibility | NE 21 |
| Degree of protection | EN 60529 |
Ambient conditions
| Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) , 70 °C (non-Ex) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity | 95 % non-condensing |
| Altitude | max. 2000 m |
| Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
| Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications
| Degree of protection | IP20 |
| Mass | approx. 1010 g |
| Dimensions | (W x H x D) 275 x 127 x 80 mm (10.8 x 5 x 3.15 inch) , without modules |
| Height127 mmWidth275 mmDepth80 mm | Height |
| Height | 127 mm |
| Width | 275 mm |
| Depth | 80 mm |
Data for application in connection with hazardous areas
| Certificate | BVS 16 ATEX E 089 X |
| Marking II 3 G Ex nA IIC T4 Gc | Marking |
| Marking | II 3 G Ex nA IIC T4 Gc |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-15:2010 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 EN 60079-15:2010 |
International approvals
| UL approval | E106378 |
| Control drawing116-0321 | Control drawing |
| Control drawing | 116-0321 |
| IECEx approval | BVS 09.0037X |
| Approved forEx nA IIC T4 Gc | Approved for |
| Approved for | Ex nA IIC T4 Gc |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs LB9018A
Available on requestPepperl Fuchs LB9019A
Available on requestPepperl Fuchs LB9022BP22320.0.E
Available on requestPepperl Fuchs LB9022BP22320.1
Available on requestPepperl Fuchs LB9023BP08110.1
Available on requestPepperl Fuchs LB9024BP24300.1
Available on requestPepperl Fuchs LB9025BP08100.1
Available on requestPepperl Fuchs LB9026BP16210.0.E