Pepperl Fuchs LB9022BP22320.1
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | LB (Zone 2, Class I/Div. 2) |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can LB9022BP22320.1 be shipped?
LB9022BP22320.1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up LB9022BP22320.1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for LB9022BP22320.1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LB9022BP22320.1, subject to availability and destination.
Redundancy Base Backplane. Backplane for LB-System, For PROFIBUS DP, PROFIBUS DP V1, PROFINET, and MODBUS RTU, Max. 22 slots for I/O modules, 5 SIL 2 output shutdown segments, Number of modules: 22, Redundancy, Fieldbus type: PROFIBUS DP/DP-V1, PROFINET or MODBUS RTU , depends on bus coupler, Redundancy. Suitable components: Extension Backplane LB9024BP24300.1 Bus Coupler LB8106* , LB8107* , LB8108* , LB8109* , LB8122*. Bus coupler: 2. Supply: 3. Output shut-down: 5 SIL2 output shutdown segmentsslots 3 ... 5, 6 ... 10, 11 ... 15, 16 ... 20, 21 ... 24. I/O modules (single width): max. 22. I/O modules (dual width): max. 11. Maximum safe voltage Um: 60 V DC (SELV/PELV). Input voltage range: 18 ... 32 V DC (SELV/PELV). Redundancy: yes. Fieldbus type: PROFIBUS DP/DP-V1, PROFINET or MODBUS RTU , depends on bus coupler. Redundancy: yes. Electromagnetic compatibility: . Directive 2014/30/EUEN 61326-1:2013: . Directive 2014/30/EU: EN 61326-1:2013. Electromagnetic compatibility: NE 21. Degree of protection: EN 60529. Ambient temperature: -40 ... 60 °C (-40 ... 140 °F) , 70 °C (non-Ex). Storage temperature: -40 ... 85 °C (-40 ... 185 °F). Relative humidity: 95 % non-condensing. Altitude: max. 2000 m. Shock resistance: shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18. Vibration resistance: frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance. Damaging gas: designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3. Degree of protection: IP20. Mass: approx. 2170 g. Dimensions: (W x H x D) 605 x 127 x 80 mm (23.8 x 5 x 3.15 inch) , without modules. Height127 mmWidth605 mmDepth80 mm: . Height: 127 mm. Width: 605 mm. Depth: 80 mm. Certificate: BVS 16 ATEX E 089 X. Marking II 3 G Ex nA IIC T4 Gc: . Marking: II 3 G Ex nA IIC T4 Gc. Directive conformity: . Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-15:2010: . Directive 2014/34/EU: EN IEC 60079-0:2018+AC:2020 EN 60079-15:2010. ATEX approval: BVS 16 ATEX E 089 X. UL approval: E106378. IECEx approval: . IECEx certificateIECEx BVS 16.0047XIECEx markingEx nA IIC T4 Gc: . IECEx certificate: IECEx BVS 16.0047X. IECEx marking: Ex nA IIC T4 Gc. Supplementary information: Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.
Specifications
General specifications
| Suitable components | Extension Backplane LB9024BP24300.1 Bus Coupler LB8106* , LB8107* , LB8108* , LB8109* , LB8122* |
Slots
| Bus coupler | 2 |
| Supply | 3 |
| Output shut-down | 5 SIL2 output shutdown segmentsslots 3 ... 5, 6 ... 10, 11 ... 15, 16 ... 20, 21 ... 24 |
| I/O modules (single width) | max. 22 |
| I/O modules (dual width) | max. 11 |
Supply
| Maximum safe voltage Um | 60 V DC (SELV/PELV) |
| Input voltage range | 18 ... 32 V DC (SELV/PELV) U |
| Redundancy | yes |
Fieldbus connection
| Fieldbus type | PROFIBUS DP/DP-V1, PROFINET or MODBUS RTU , depends on bus coupler |
| Redundancy | yes |
Directive conformity
| Electromagnetic compatibility | |
| Directive 2014/30/EUEN 61326-1:2013 | Directive 2014/30/EU |
| Directive 2014/30/EU | EN 61326-1:2013 |
Conformity
| Electromagnetic compatibility | NE 21 |
| Degree of protection | EN 60529 |
Ambient conditions
| Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) , 70 °C (non-Ex) |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity | 95 % non-condensing |
| Altitude | max. 2000 m |
| Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
| Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cyclesfrequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
Mechanical specifications
| Degree of protection | IP20 |
| Mass | approx. 2170 g |
| Dimensions | (W x H x D) 605 x 127 x 80 mm (23.8 x 5 x 3.15 inch) , without modules |
| Height127 mmWidth605 mmDepth80 mm | Height |
| Height | 127 mm |
| Width | 605 mm |
| Depth | 80 mm |
Data for application in connection with hazardous areas
| Certificate | BVS 16 ATEX E 089 X |
| Marking II 3 G Ex nA IIC T4 Gc | Marking |
| Marking | II 3 G Ex nA IIC T4 Gc |
| Directive conformity | |
| Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-15:2010 | Directive 2014/34/EU |
| Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 EN 60079-15:2010 |
International approvals
| ATEX approval | BVS 16 ATEX E 089 X |
| UL approval | E106378 |
| IECEx approval | |
| IECEx certificateIECEx BVS 16.0047XIECEx markingEx nA IIC T4 Gc | IECEx certificate |
| IECEx certificate | IECEx BVS 16.0047X |
| IECEx marking | Ex nA IIC T4 Gc |
General information
| Supplementary information | Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
More Pepperl Fuchs parts
Available on requestPepperl Fuchs LB9017A
Available on requestPepperl Fuchs LB9018A
Available on requestPepperl Fuchs LB9019A
Available on requestPepperl Fuchs LB9022BP22320.0.E
Available on requestPepperl Fuchs LB9023BP08110.0.E
Available on requestPepperl Fuchs LB9023BP08110.1
Available on requestPepperl Fuchs LB9024BP24300.1
Available on requestPepperl Fuchs LB9025BP08100.1