Pepperl Fuchs LB6017E

Digital Output with Shutdown Input

MPN
LB6017E
Price and lead time confirmed within 1 business day

Discontinued by Pepperl Fuchs — we can still source the original LB6017E (new, used or refurbished, subject to availability). Request a quote below.

Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

What happens next
  1. We check stock, condition and lead time
  2. You get a written quote by email
  3. Approve it and we ship — in-stock parts within 1 business day
  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via
  • 100% positive eBay feedback

Have spare Pepperl Fuchs parts? We buy surplus →

What is the Pepperl Fuchs LB6017E?

2-channel

Outputs Ex ic

Installation in Zone 2 or safe area

Line fault detection switched on and off

Positive or negative logic selectable

Simulation mode for service operations (forcing)

Permanently self-monitoring

Output with watchdog

Output with bus-independent safety shutdown

Module can be exchanged under voltage (hot swap)

2-channel, Outputs Ex ic, Installation in Zone 2 or safe area, Line fault detection switched on and off, Explosion protection: Ex ic

Pepperl+Fuchs has archived the LB6017E: it is no longer part of the current range. PartnerPLC sources discontinued Pepperl+Fuchs parts on the surplus market for maintenance and repair of existing installations — request a quote for availability, condition, price and lead time.

Specifications

Slots

Order code (Pepperl+Fuchs part number)281974
Occupied slots1
LifecycleDiscontinued — archived by Pepperl+Fuchs

Supply

Connectionbackplane bus
Rated voltageUse only in connection with the power supplies LB9*** Ur
Power dissipation1.7 W
Power consumption2.7 W

Internal bus

Connectionbackplane bus
Interfacemanufacturer-specific bus to standard com unit

Digital output

Number of channels2
Suitable field devices: Field deviceSolenoid Valve
Suitable field devices: Field device [2]audible alarm
Suitable field devices: Field device [3]visual alarm
Connectionchannel I: 1+, 4/5/6/8-; channel II: 7+, 4/5/6/8-
Internal resistor131 Ω , both channels parallel 66 Ω Ri
Current limit50 mA both channels parallel 100 mA Imax
Open loop voltage16.5 V , both channels parallel 16.5 V Us
Line fault detectioncan be switched on/off for each channel via configuration tool also when turned off (every 2.5 s the valve is turned on for 2 ms)
Short-circuit< 50 Ω
Open-circuit> 10 kΩ
Response time10 ms (depending on bus cycle time)
Watchdogwithin 0.5 s the device goes in safe state, e.g. after loss of communication

Indicators/settings

LED indicationPower LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1, 2) red: line fault (lead breakage or short circuit) , yellow: state of digital I/O (0/1) Mode LED (M) white: Parallel operation of outputs
Codingoptional mechanical coding via front socket

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013

Conformity

Electromagnetic compatibilityNE 21
Degree of protectionIEC 60529
Environmental testEN 60068-2-14
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6
Damaging gasEN 60068-2-42
Relative humidityEN 60068-2-78

Ambient conditions

Ambient temperature-40 ... 60 °C (-40 ... 140 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity95 % non-condensing
Altitudemax. 2000 m
Shock resistanceshock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistancefrequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3

Mechanical specifications

Degree of protectionIP20 when mounted on backplane
Connectionremovable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Massapprox. 150 g
Dimensions: Height100 mm
Dimensions: Width16 mm
Dimensions: Depth102 mm

Data for application in connection with hazardous areas

EU-type examination certificateEXA 16 ATEX 0035X
MarkingII 3 G Ex nA [ic] IIC T4 Gc
Output: Voltage17.8 V Uo
Output: Current162 mA Io
Output: Power721 mW Po
Output: Internal capacitance12 nF Ci
Output: Internal inductance0 mH Li
Output (both channels parallel): Voltage17.8 V Uo
Output (both channels parallel): Current324 mA Io
Output (both channels parallel): Power1442 mW Po
Output (both channels parallel): Internal capacitance24 nF Ci
Output (both channels parallel): Internal inductance0 mH Li
Galvanic isolation: Output/power supply, internal bussafe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 EN 60079-11:2012 EN 60079-15:2010

International approvals

ATEX approvalEXA 16 ATEX 0035X
IECEx approvalIECEx EXA 16.0010X
Approved forEx nA [ic] IIC T4 Gc

General information

System informationThe module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure.
Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

LB6017E: frequently asked questions

Can I still buy the LB6017E now that it is discontinued?

Yes. Pepperl Fuchs has discontinued the LB6017E, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time.

When can LB6017E be shipped?

LB6017E is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up LB6017E in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for LB6017E and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for LB6017E, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs LB6001A2 – Relay output
Pepperl Fuchs
LB6001A2

Relay output

Pepperl Fuchs LB6006A – Relay output
Pepperl Fuchs
LB6006A

Relay output

Pepperl Fuchs LB6006A2 – Relay output
Pepperl Fuchs
LB6006A2

Relay output

Pepperl Fuchs LB6016E – Digital Output with Shutdown Input
Pepperl Fuchs
LB6016E

Digital Output with Shutdown Input

Pepperl Fuchs LB6116E – Digital Output with Shutdown Input
Pepperl Fuchs
LB6116E

Digital Output with Shutdown Input

Pepperl Fuchs LB6117E – Digital Output with Shutdown Input
Pepperl Fuchs
LB6117E

Digital Output with Shutdown Input

Pepperl Fuchs LB7004A – Universal Input/Output (HART)
Pepperl Fuchs
LB7004A

Universal Input/Output (HART)

Pepperl Fuchs LB7004E – Universal Input/Output
Pepperl Fuchs
LB7004E

Universal Input/Output

Pepperl Fuchs LB6017EPrice and lead time confirmed within 1 business day
Request a Quote