What is the Pepperl Fuchs KFD2-UT2-Ex2-1?

2-channel isolated barrier

24 V DC supply (Power Rail)

Thermocouple, RTD, potentiometer or voltage input

Usable as signal splitter (1 input and 2 outputs)

Voltage output 0/1 V ... 5 V

Configurable by PACTware

Line fault (LFD) and sensor burnout detection

Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511

2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and 2 outputs), Voltage output 0/1 V ... 5 V, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 20 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection, Type [2]: 3-wire connection

Specifications

General specifications

Order code (Pepperl+Fuchs part number)248768
Signal typeAnalog input
LifecycleActive (current Pepperl+Fuchs product)

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2

Supply

Connectionterminals 14+, 15- or power feed module/Power Rail
Rated voltage20 ... 30 V DC Ur
Ripplewithin the supply tolerance
Power dissipation≤ 0.8 W
Power consumptionmax. 0.8 W

Interface

Programming interfaceprogramming socket

Input

Connection sidefield side
Connectionterminals 1, 2, 3; 4, 5, 6
RTDtype Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995) type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94) type Cu10, Cu50, Cu100 (P50353-92) type Ni100 (DIN 43760)
Measuring currentapprox. 200 µA with RTD
Types of measuring2-, 3-wire connection
Lead resistancemax. 50 Ω per line
Measurement loop monitoringsensor breakage, sensor short-circuit
Thermocouplestype B, E, J, K, N, R, S, T (IEC 584-1: 1995) type L (DIN 43710: 1985) type TXK, TXKH, TXA (P8.585-2001)
Cold junction compensationexternal and internal
Measurement loop monitoringsensor breakage
Potentiometer0 ... 20 kΩ (2-wire connection), 0.8 ... 20 kΩ (3-wire connection)
Voltageselectable within the range -100 ... 100 mV
Input resistance≥ 1 MΩ (-100 ... 100 mV)

Output

Connection sidecontrol side
Voltage output0 ... 5 V or 1 ... 5 V ; output resistance: ≤ 5 Ω ; load: ≥ 10 kΩ
Connectionoutput I: terminals 7-, 8+ output II: terminals 10-, 11+
Fault signaldownscale 0 V or 0.5 V, upscale 5.375 V

Transfer characteristics

Deviation: After calibrationPt100: ± (0.06 % of measurement value in K + 0.1 K (4-wire connection)) thermocouple: ± (0.05 % of measurement value in °C + 1 K (1.2 K for types R and S)) , includes ± 0.8 K fault of the cold junction compensation (CJC) mV: ± 50 µV potentiometer: ± 0.05 % of full scale, (excludes faults due to lead resistance) output: 1 to 5 V output: ± 4 mV from 0 to 103.1 % of span; 0 to 5 V output: ± 4 mV from 0.3 to 102.5 % of span
Deviation: Influence of ambient temperaturePt100: ± (0.0015 % of measurement value in K + 0.0075 % of span)/K ΔTamb*) thermocouple: ± (0.02 K + 0.005 % of measurement value in °C + 0.0075 % of span)/K ΔTamb*) , influence of cold junction compensation (CJC) included: mV: ± (0.01 % of measurement value + 0.0075 % of span)/K ΔTamb*) potentiometer: ± 0.0075 % of span/K ΔTamb*) *) ΔTamb = ambient temperature change referenced to 23 °C (296 K)
Deviation: Influence of supply voltage< 0.01 % of span
Reaction timeworst case value (sensor breakage and/or sensor short circuit detection enabled) mV: 1.2 s, thermocouples with CJC: 1.4 s, thermocouples with fixed ref. temp: 1.4 s, 3- or 4-wire RTD: 1.1 s, 2-wire RTD: 920 ms, Potentiometer: 3-wire connection 2.8 s, 2-wire connection 2.25 s

Galvanic isolation

Output/supply, programming inputfunctional insulation, rated insulation voltage 50 V AC There is no electrical isolation between the programming input and the supply. The programming cable provides galvanic isolation so that ground loops are avoided.

Indicators/settings

Display elementsLEDs
Configurationvia PACTware
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013 (industrial locations)

Conformity

Electromagnetic compatibilityNE 21:2006
Degree of protectionIEC 60529:2001
Protection against electrical shockUL 61010-1:2004

Ambient conditions

Ambient temperature-20 ... 60 °C (-4 ... 140 °F)

Mechanical specifications

Degree of protectionIP20
Connectionscrew terminals
Massapprox. 130 g
Dimensions20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2
Height119 mm
Width20 mm
Depth115 mm
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas

EU-type examination certificateCESI 04 ATEX 143
MarkingII (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
InputEx ia
Inputsterminals 1, 2, 3, 4, 5, 6 (for passive equipment)
Voltage Uo9 V
Current Io22 mA
Power Po50 mW
Analog outputs, power supply, collective error: Maximum safe voltage250 V (Attention! This is not the rated voltage.) Um
Interface: Maximum safe voltage250 V (Attention! The rated voltage is lower.), RS 232 Um
CertificateTÜV 02 ATEX 1797 X
MarkingII 3G Ex nA II T4
Galvanic isolation: Input/Other circuitssafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EUEN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010 , EN 50303:2000

International approvals

UL approval: Control drawing116-0410
CSA approval: Control drawing116-0314 (cCSAus) 116-0347
IECEx approval: IECEx certificateIECEx TUN 07.0003 IECEx CML 16.0126X
IECEx approval: IECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I Ex nA IIC T4 Gc

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

KFD2-UT2-Ex2-1: frequently asked questions

When can KFD2-UT2-Ex2-1 be shipped?

KFD2-UT2-Ex2-1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up KFD2-UT2-Ex2-1 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for KFD2-UT2-Ex2-1 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD2-UT2-Ex2-1, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs KFD2-UT2-1 – Universal Temperature Converter
Pepperl Fuchs
KFD2-UT2-1

Universal Temperature Converter

Pepperl Fuchs KFD2-UT2-2 – Universal Temperature Converter
Pepperl Fuchs
KFD2-UT2-2

Universal Temperature Converter

Pepperl Fuchs KFD2-UT2-Ex1 – Universal Temperature Converter
Pepperl Fuchs
KFD2-UT2-Ex1

Universal Temperature Converter

Pepperl Fuchs KFD2-UT2-Ex2 – Universal Temperature Converter
Pepperl Fuchs
KFD2-UT2-Ex2

Universal Temperature Converter

Pepperl Fuchs KFD2-UT2-Ex2-1Price and lead time confirmed within 1 business day
Request a Quote