Pepperl Fuchs KFD2-SLD-Ex1.13100
Solenoid Driver
- MPN
- KFD2-SLD-Ex1.13100
- Category
- K-System (DIN Rail Mounting)
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Pepperl Fuchs KFD2-SLD-Ex1.13100?
1-channel isolated barrier
24 V DC supply (Power Rail)
Logic input
Output 100 mA at 13 V DC
Alternating outputs for the operation of solenoids with 2 coils
High output power for IIB gas group
Line fault transparency (LFT)
Test pulse immunity
Up to SIL 3 acc. to IEC/EN 61508
1-channel isolated barrier, 24 V DC supply (Power Rail), Logic input, Output 100 mA at 13 V DC, Alternating outputs for the operation of solenoids with 2 coils, High output power for IIB gas group, Line fault transparency (LFT), Test pulse immunity, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, Number of channels: 1-channel, Line fault transparency, Safety Integrity Level (SIL): SIL 3, Systematic capability (SC): SC 3, Rated voltage: 19 ... 30 V DC , loop powered, Type: logic input
Specifications
General specifications
| Order code (Pepperl+Fuchs part number) | 243753 |
| Signal type | Digital Output |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 3 |
| Systematic capability (SC) | SC 3 |
Supply
| Connection | Power Rail or terminals 14+, 15- |
| Rated voltage | 19 ... 30 V DC loop powered Ur |
| Input current | 115 mA at 24 V , 130 Ω load |
| Power dissipation | 1.5 W at 24 V , 130 Ω load |
Input
| Connection side | control side |
| Connection | input 1: terminals 7+, 8- , optional Rext between terminals 7 and 9 input 2: terminals 10+, 11- , optional Rext between terminals 10 and 12 |
| Test pulse length | max. 2 ms from DO card |
| Input current | approx. 6 mA at 24 V DC If necessary, the current value can be increased by resistor Rext. |
| Signal level | 1-signal: 15 ... 30 V DC 0-signal: 0 ... 5 V DC |
Output
| Connection side | field side |
| Connection | output 1: terminals 1+, 2-, 3 output 2: terminals 4+, 5-, 6- |
| Internal resistor | approx. 64 Ω Ri |
| Current | typ. 100 mA Ie |
| Voltage | ≥ 13 V Ue |
| Current limit | 105 mA Imax |
| Open loop voltage | typ. 19.2 V Us |
| Load | nominal 0.08 ... 1 kΩ |
| Switching frequency | max. 2 Hz f |
| Energized/De-energized delay | 30 ms / 30 ms |
Galvanic isolation
| Input/power supply | basic insulation according to IEC/EN 61010-1, rated insulation voltage 60 Veff |
| Input/input | basic insulation according to IEC/EN 61010-1, rated insulation voltage 60 Veff |
| Output/Output | basic insulation according to IEC/EN 61010-1, rated insulation voltage 60 Veff |
| Output/other circuits | basic insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
Indicators/settings
| Display elements | LEDs |
| Control elements | DIP switch |
| Configuration | via DIP switches |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Electromagnetic compatibility | NE 21:2011 For further information see system description. |
| Degree of protection | IEC 60529:2001 |
| Protection against electrical shock | EN 61010-1:2010 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | screw terminals |
| Mass | approx. 200 g |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2 |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| EU-type examination certificate | EXA 17 ATEX 0076X |
| Marking | II 3(1)G Ex ec [ia IIB Ga] IIC T4 Gc [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Voltage | 22.2 V Uo |
| Current | 360 mA Io |
| Power | 1990 mW Po |
| Supply: Maximum safe voltage | 60 V (Attention! The rated voltage can be lower.) Um |
| Input: Maximum safe voltage | 60 V (Attention! The rated voltage can be lower.) Um |
| Galvanic isolation: Output/Output | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 60 V |
| Galvanic isolation: Output/other circuits | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Directive conformity: Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 |
International approvals
| IECEx approval: IECEx certificate | IECEx EXA 17.0019X |
| IECEx approval: IECEx marking | Ex ec [ia IIB Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
No matching specifications
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
Certificates (7)
- China SITIIAS CCC Ex Certificate (2021322316003613 (Singapore))
- EU Declaration of Conformity (Pepperl+Fuchs)
- DNV Marine (TAA00001WX)
- India PESO (India) CCOE (A/P/HQ/KA/104/6092 (P576842))
- Europe EXA ATEX (EXA 17 ATEX 0076X)
- Worldwide TUV Nord Functional Safety Certificate (TUV NORD 44 207 13734006)
- Ukraine SERTIS Ex (SC 21.0646 X)
KFD2-SLD-Ex1.13100: frequently asked questions
When can KFD2-SLD-Ex1.13100 be shipped?
KFD2-SLD-Ex1.13100 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KFD2-SLD-Ex1.13100 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KFD2-SLD-Ex1.13100 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD2-SLD-Ex1.13100, subject to availability and destination.