What is the Pepperl Fuchs KFD2-SLD-Ex2.1245-Y1?
2-channel isolated barrier
24 V DC supply (bus or loop powered)
Output 45 mA at 12 V DC
Line fault transparency (LFT)
Test pulse immunity
2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 12 V DC, Line fault transparency (LFT), Test pulse immunity, Housing width: 20 mm, Number of channels: 2-channel, Line fault transparency, Rated voltage: 18 ... 30 V DC, Type: logic input, Type [2]: field device supply, Test pulse immunity, Field device: 2 x Valve, Field device [2]: 2 x audible alarm, Field device [3]: 2 x visual alarm, Line fault detection, Voltage: ≥ 12 V
Specifications
General specifications
| Order code (Pepperl+Fuchs part number) | 70178495 |
| Signal type | Digital Output |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Supply
| Connection | Power Rail or terminals 14+, 15- |
| Rated voltage | 18 ... 30 V DC Ur |
| Power consumption | max. 3.5 W at 45 mA output current |
Input
| Connection side | control side |
| Connection | terminals 7, 8, 9 |
| Test pulse length | max. 2 ms from DO card |
| Signal level | loop powered 1-signal: 18 ... 30 V DC 0-signal: 0 ... 5 V DC bus powered 1-signal: 15 ... 30 V DC (current limited to 5 mA) 0-signal: 0 ... 5 V DC |
| Rated current | 0-signal: typ. 1.6 mA at 1.5 V DC; typ. 8 mA at 3 V DC (maximum leakage current DO card) 1-signal: ≥ 20 mA (minimum load current DO card) Ir |
| Inrush current | ≤ 200 mA after 100 µs |
Output
| Connection side | field side |
| Connection | channel 1: terminals 1+, 2-, 3- channel 2: terminals 4+, 5-, 6- |
| Internal resistor | 236 Ω Ri |
| Current | 45 mA Ie |
| Voltage | ≥ 12 V Ue |
| Current limit | 45 mA Imax |
| Open loop voltage | min. 23.6 V Us |
| Load | nominal 0.05 ... 20 kΩ , valid range for line fault detection (LFD) |
| Energized/De-energized delay | ≤ 20 ms / ≤ 20 ms |
| Line fault detection: Test current | max. 350 µA , calculated by ILFD = 3.3 V / (10 kΩ + RLoad) |
Galvanic isolation
| Input/Output | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Power supply/Output | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
Indicators/settings
| Display elements | LEDs |
| Control elements | DIP switch |
| Configuration | via DIP switches |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
Conformity
| Electromagnetic compatibility | NE 21:2017 , EN IEC 61326-1:2021 (industrial locations) , EN IEC 61326-3-2:2018 For further information see system description. |
Ambient conditions
| Ambient temperature | -40 ... 60 °C (-40 ... 140 °F) extended ambient temperature range up to 70 °C (158 °F), refer to manual for necessary mounting conditions |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | screw terminals |
| Mass | approx. 150 g |
| Dimensions | 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch) (W x H x D) , housing type B2 |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| EU-type examination certificate | FIDI 21 ATEX 0091 X |
| Marking | II 3(1)G Ex ec [ia Ga] IIC T4 Gc [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Output | Ex ia |
| Voltage | 25.2 V Uo |
| Current | 110 mA Io |
| Power | 693 mW (linear characteristic) Po |
| Supply: Maximum safe voltage | 250 V (Attention! The rated voltage can be lower.) Um |
| Input: Maximum safe voltage | 250 V (Attention! The rated voltage can be lower.) Um |
| Collective error message: Maximum safe voltage | 250 V (Attention! The rated voltage can be lower.) Um |
| Galvanic isolation: Input/Output | safe electrical isolation acc. to IEC/EN 60079-11, rated insulation voltage 300 Vrms |
| Galvanic isolation: Output/power supply | safe electrical isolation acc. to IEC/EN 60079-11, rated insulation voltage 300 Vrms |
| Directive conformity: Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 |
International approvals
| UL approval | E106378 |
| Control drawing | 116-0488 |
| IECEx approval: IECEx certificate | IECEx FIDI 21.0009X |
| IECEx approval: IECEx marking | Ex ec [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
No matching specifications
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
Certificates (7)
- EU Declaration of Conformity (Pepperl+Fuchs)
- China SITIIAS CCC Ex Certificate (2025322316006867 (Vietnam))
- China SITIIAS CCC Ex Certificate (2022322316004905 (Singapore))
- United Kingdom CML UK-Type Examination Certificate UKEX Category (1) D UKEX Category (M1) UKEX Category 3 (1) G (CML 22UKEX2328X)
- Europe Fiditas ATEX Category (1) D ATEX Category (M1) ATEX Category 3 (1) G (FIDI 21 ATEX 0091X)
- Canada USA UL Hazardous Location UL E106378 cULus (CoC E106378 Rep Ref E106378-20221005)
- India PESO (India) CCOE (A/P/HQ/KA/104/6092 (P576842))
KFD2-SLD-Ex2.1245-Y1: frequently asked questions
When can KFD2-SLD-Ex2.1245-Y1 be shipped?
KFD2-SLD-Ex2.1245-Y1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KFD2-SLD-Ex2.1245-Y1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KFD2-SLD-Ex2.1245-Y1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD2-SLD-Ex2.1245-Y1, subject to availability and destination.
More Pepperl Fuchs parts