Pepperl Fuchs KFD2-GUT-Ex1.D
Temperature Converter with Trip Values
- MPN
- KFD2-GUT-Ex1.D
- Category
- K-System (DIN Rail Mounting)
Request a Quote
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Pepperl Fuchs KFD2-GUT-Ex1.D?
1-channel isolated barrier
24 V DC supply (Power Rail)
Thermocouple, RTD, potentiometer or voltage input
Redundant TC input
Current output 0/4 mA ... 20 mA
2 relay contact outputs
Configurable by PACTware or keypad
Line fault (LFD) and sensor burnout detection
Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511
1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection
Specifications
General specifications
| Order code (Pepperl+Fuchs part number) | 231225 |
| Signal type | Analog input |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 2 |
Supply
| Connection | terminals 23+, 24- or power feed module/Power Rail |
| Rated voltage | 20 ... 30 V DC Ur |
| Rated current | approx. 100 mA Ir |
| Power dissipation/power consumption | ≤ 2 W / 2.2 W |
Interface
| Programming interface | programming socket |
Input
| Connection side | field side |
| Connection | terminals 1, 2, 3, 4, 6 |
| RTD | Pt100, Pt500, Pt1000, Ni100, Ni1000 |
| Types of measuring | 2-, 3-, 4-wire technology |
| Lead resistance | max. 50 Ω |
| Measurement loop monitoring | sensor breakage, sensor short-circuit |
| Thermocouples | type B, E, J, K, L, N, R, S, T (IEC 584-1: 1995) |
| Cold junction compensation | external and internal |
| Measurement loop monitoring | sensor breakage |
| Potentiometer | 0.8 ... 20 kΩ |
| Types of measuring | 2-, 3-, 5-wire technology |
| Voltage | 0 ... 10 V , 2 ... 10 V , 0 ... 1 V , -100 ... 100 mV |
| Input resistance | ≥ 250 kΩ (0 ... 10 V) min. 1 MΩ (0 ... 1 V, -100 ... 100 mV) |
| Measuring current | approx. 400 µA with resistance measuring sensor |
Output
| Connection side | control side |
| Connection | output I: terminals 10, 11, 12 output II: terminals 16, 17, 18 output III: terminals 8+, 7- |
| Output I, II | relay |
| Contact loading | 250 V AC / 2 A / cos φ ≥ 0.7 ; 40 DC / 2 A |
| Mechanical life | 5 x 107 switching cycles |
| Energized/De-energized delay | approx. 20 ms / approx. 20 ms |
| Output III | Analog current output |
| Current range | 0 ... 20 mA or 4 ... 20 mA |
| Open loop voltage | max. 24 V DC |
| Load | max. 650 Ω |
| Fault signal | downscale I ≤ 3.6 mA, upscale I ≥ 21 mA (acc. NAMUR NE43) |
| Collective error message | Power Rail |
Transfer characteristics
| Deviation: Temperature effect | Input: 0.005 %/K (50 ppm) of span ; current output: 0.005 %/K (50 ppm) of span |
| Deviation: RTD | max. 0.2 % of span |
| Deviation: Thermocouples | max. 10µV deviation of CJC: ±0.8 K |
| Deviation: Voltage | 0.1 % of span |
| Deviation: Potentiometer | 0.1 % of span when 0.5 % of span when > 5 kΩ |
| Deviation: Current output | max. 20 µA |
| Sampling rate | approx. 700 ms |
Galvanic isolation
| Input/Other circuits | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Output I, II against eachother | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Output I, II/other circuits | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Output III/power supply and collective error | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
| Interface/power supply | reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff |
Indicators/settings
| Display elements | LEDs , display |
| Control elements | Control panel |
| Configuration | via operating buttons via PACTware |
| Labeling | space for labeling at the front |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 61326-1:2013 (industrial locations) |
| Low voltage: Directive 2014/35/EU | EN 61010-1:2010 |
Conformity
| Electromagnetic compatibility | NE 21:2007 |
| Degree of protection | IEC 60529:2001 |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
Mechanical specifications
| Degree of protection | IP20 |
| Connection | screw terminals |
| Mass | 300 g |
| Dimensions | 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2 |
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
Data for application in connection with hazardous areas
| EU-type examination certificate | TÜV 03 ATEX 2140 |
| Marking | II (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I |
| Input | Ex ia |
| Supply: Maximum safe voltage | 40 V DC (Attention! The rated voltage can be lower.) Um |
| Input | terminals 2, 6 (for active equipment) |
| Voltage | 13.1 V Uo |
| Current | 8 mA Io |
| Power | 67 mW Po |
| Voltage | 29 V Ui |
| Current | 11 mA Ii |
| Power | 200 mW Pi |
| Inputs | terminals 1, 2, 3, 4, 6 (for passive equipment) |
| Voltage Uo | 13.1 V |
| Current Io | 21 mA |
| Power Po | 67 mW |
| Analog output: Maximum safe voltage | 40 V (Attention! The rated voltage can be lower.) Um |
| Interface: Maximum safe voltage | 40 V (Attention! The rated voltage can be lower.) , RS 232 Um |
| Certificate | PF 08 CERT 1213 X |
| Marking | II 3G Ex nA nC IIC T4 Gc |
| Output I, II: Contact loading | 50 V AC/2 A/cos φ > 0.7; 40 V DC/1 A resistive load |
| Galvanic isolation: Input/Other circuits | safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V |
| Directive conformity: Directive 2014/34/EU | EN IEC 60079-0:2018+AC:2020 , EN IEC 60079-11:2024 , EN 60079-15:2010 |
International approvals
| IECEx approval: IECEx certificate | IECEx TUN 09.0019 |
| IECEx approval: IECEx marking | [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I |
General information
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
No matching specifications
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
Certificates (8)
- EU Declaration of Conformity (Pepperl+Fuchs)
- China SITIIAS CCC Ex Certificate (2020322316001421 (Singapore))
- South Africa MASC (MASC MS/17-0880)
- DNV Marine (TAA00001WX)
- India PESO (India) CCOE (A/P/HQ/KA/104/5959 (P542586))
- Korea KOSHA (18-AV4BO-0230)
- Europe Pepperl+Fuchs ATEX Category 3 Certificate of Compliance (PF 08 CERT 1213 X)
- exida Functional Safety Assessment (P+F 05/03-24 R023)
KFD2-GUT-Ex1.D: frequently asked questions
When can KFD2-GUT-Ex1.D be shipped?
KFD2-GUT-Ex1.D is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up KFD2-GUT-Ex1.D in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for KFD2-GUT-Ex1.D and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD2-GUT-Ex1.D, subject to availability and destination.
More Pepperl Fuchs parts