What is the Pepperl Fuchs KFD2-GUT-Ex1.D?

1-channel isolated barrier

24 V DC supply (Power Rail)

Thermocouple, RTD, potentiometer or voltage input

Redundant TC input

Current output 0/4 mA ... 20 mA

2 relay contact outputs

Configurable by PACTware or keypad

Line fault (LFD) and sensor burnout detection

Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511

1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 mA ... 20 mA, 2 relay contact outputs, Configurable by PACTware or keypad, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511, Housing width: 40 mm, Number of channels: 1-channel, Trip relay, Safety Integrity Level (SIL): SIL 2, Rated voltage: 20 ... 30 V DC, Type: 2-wire connection

Specifications

General specifications

Order code (Pepperl+Fuchs part number)231225
Signal typeAnalog input
LifecycleActive (current Pepperl+Fuchs product)

Functional safety related parameters

Safety Integrity Level (SIL)SIL 2

Supply

Connectionterminals 23+, 24- or power feed module/Power Rail
Rated voltage20 ... 30 V DC Ur
Rated currentapprox. 100 mA Ir
Power dissipation/power consumption≤ 2 W / 2.2 W

Interface

Programming interfaceprogramming socket

Input

Connection sidefield side
Connectionterminals 1, 2, 3, 4, 6
RTDPt100, Pt500, Pt1000, Ni100, Ni1000
Types of measuring2-, 3-, 4-wire technology
Lead resistancemax. 50 Ω
Measurement loop monitoringsensor breakage, sensor short-circuit
Thermocouplestype B, E, J, K, L, N, R, S, T (IEC 584-1: 1995)
Cold junction compensationexternal and internal
Measurement loop monitoringsensor breakage
Potentiometer0.8 ... 20 kΩ
Types of measuring2-, 3-, 5-wire technology
Voltage0 ... 10 V , 2 ... 10 V , 0 ... 1 V , -100 ... 100 mV
Input resistance≥ 250 kΩ (0 ... 10 V) min. 1 MΩ (0 ... 1 V, -100 ... 100 mV)
Measuring currentapprox. 400 µA with resistance measuring sensor

Output

Connection sidecontrol side
Connectionoutput I: terminals 10, 11, 12 output II: terminals 16, 17, 18 output III: terminals 8+, 7-
Output I, IIrelay
Contact loading250 V AC / 2 A / cos φ ≥ 0.7 ; 40 DC / 2 A
Mechanical life5 x 107 switching cycles
Energized/De-energized delayapprox. 20 ms / approx. 20 ms
Output IIIAnalog current output
Current range0 ... 20 mA or 4 ... 20 mA
Open loop voltagemax. 24 V DC
Loadmax. 650 Ω
Fault signaldownscale I ≤ 3.6 mA, upscale I ≥ 21 mA (acc. NAMUR NE43)
Collective error messagePower Rail

Transfer characteristics

Deviation: Temperature effectInput: 0.005 %/K (50 ppm) of span ; current output: 0.005 %/K (50 ppm) of span
Deviation: RTDmax. 0.2 % of span
Deviation: Thermocouplesmax. 10µV deviation of CJC: ±0.8 K
Deviation: Voltage0.1 % of span
Deviation: Potentiometer0.1 % of span when 0.5 % of span when > 5 kΩ
Deviation: Current outputmax. 20 µA
Sampling rateapprox. 700 ms

Galvanic isolation

Input/Other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II against eachotherreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II/other circuitsreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output III/power supply and collective errorreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Interface/power supplyreinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Indicators/settings

Display elementsLEDs , display
Control elementsControl panel
Configurationvia operating buttons via PACTware
Labelingspace for labeling at the front

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013 (industrial locations)
Low voltage: Directive 2014/35/EUEN 61010-1:2010

Conformity

Electromagnetic compatibilityNE 21:2007
Degree of protectionIEC 60529:2001

Ambient conditions

Ambient temperature-20 ... 60 °C (-4 ... 140 °F)

Mechanical specifications

Degree of protectionIP20
Connectionscrew terminals
Mass300 g
Dimensions40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2
Mountingon 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas

EU-type examination certificateTÜV 03 ATEX 2140
MarkingII (1)G [Ex ia Ga] IIC [exsign] II (1)D [Ex ia Da] IIIC [exsign] I (M1) [Ex ia Ma] I
InputEx ia
Supply: Maximum safe voltage40 V DC (Attention! The rated voltage can be lower.) Um
Inputterminals 2, 6 (for active equipment)
Voltage13.1 V Uo
Current8 mA Io
Power67 mW Po
Voltage29 V Ui
Current11 mA Ii
Power200 mW Pi
Inputsterminals 1, 2, 3, 4, 6 (for passive equipment)
Voltage Uo13.1 V
Current Io21 mA
Power Po67 mW
Analog output: Maximum safe voltage40 V (Attention! The rated voltage can be lower.) Um
Interface: Maximum safe voltage40 V (Attention! The rated voltage can be lower.) , RS 232 Um
CertificatePF 08 CERT 1213 X
MarkingII 3G Ex nA nC IIC T4 Gc
Output I, II: Contact loading50 V AC/2 A/cos φ > 0.7; 40 V DC/1 A resistive load
Galvanic isolation: Input/Other circuitssafe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN IEC 60079-11:2024 , EN 60079-15:2010

International approvals

IECEx approval: IECEx certificateIECEx TUN 09.0019
IECEx approval: IECEx marking[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I

General information

Supplementary informationObserve the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

KFD2-GUT-Ex1.D: frequently asked questions

When can KFD2-GUT-Ex1.D be shipped?

KFD2-GUT-Ex1.D is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up KFD2-GUT-Ex1.D in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for KFD2-GUT-Ex1.D and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for KFD2-GUT-Ex1.D, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs KFD2-GS-1.2W – Current/Voltage Trip Value
Pepperl Fuchs
KFD2-GS-1.2W

Current/Voltage Trip Value

Pepperl Fuchs KFD2-GUT-1.D – Temperature Converter with Trip Values
Pepperl Fuchs
KFD2-GUT-1.D

Temperature Converter with Trip Values

Pepperl Fuchs KFD2-HMM-16 – HART MUX Primary Module
Pepperl Fuchs
KFD2-HMM-16

HART MUX Primary Module

Pepperl Fuchs KFD2-PT2-Ex1 – Potentiometer Converter
Pepperl Fuchs
KFD2-PT2-Ex1

Potentiometer Converter

Pepperl Fuchs KFD2-GUT-Ex1.D€380.54
Buy Now