MMP-T32 Mitsubishi Low-voltage switchgear Motor Circuit Breaker
Discontinued by Mitsubishi Electric (Factory Automation) — we can still source the original MMP-T32 (new, used or refurbished, subject to availability). Request a quote below.
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Mitsubishi Low-voltage switchgear – Motor Circuit Breakers |
| Lifecycle | Discontinued |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
Can I still buy the MMP-T32 now that it is discontinued?
Yes. Mitsubishi Electric (Factory Automation) has discontinued the MMP-T32, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time.
When can MMP-T32 be shipped?
MMP-T32 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up MMP-T32 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for MMP-T32 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for MMP-T32, subject to availability and destination.
The Mitsubishi Electric MMP-T32 is a motor Circuit Breaker in the Low-voltage switchgear. Motor Circuit Breakers Rated Current Setting Range: 0.1 to 32A Terminal Cover. Mitsubishi Electric has discontinued it (2025/09 Discontinued); PartnerPLC sources discontinued Mitsubishi parts on the surplus market for maintenance of existing machines. Specifications and manuals below are Mitsubishi Electric's own data.
Specifications
Product
| Series | Low-voltage switchgear |
| Sales status | 2025/09 Discontinued (Mitsubishi Electric) |
| Outline | Motor Circuit Breakers Rated Current Setting Range: 0.1 to 32A Terminal Cover |
Specifications
| Product Specification | Motor Circuit Breakers |
| No. of Poles | 3 |
| Handle Shape | Tumbler Handle |
| Rated Current In [A] | 0.1 to 32 |
| Rated Operational Voltage Ue [V] | 100 to 690 |
| Rated Operating Frequency [Hz] | 50/60 |
| Rated Insulation Voltage Ui [V] | 690 |
| Rated Impulse Withstand Voltage [kV] | 6 |
| Rated Short Circuit Breaking Capacity [kA]: 200/240V: Icu | 100 |
| Rated Short Circuit Breaking Capacity [kA]: 200/240V: Ics | 100 |
| Rated Short Circuit Breaking Capacity [kA]: 400/415V: Icu | 100(Heater Designation 0.16 to 13) 50(Heater Designation 18 to 32) |
| Rated Short Circuit Breaking Capacity [kA]: 400/415V: Ics | 100(Heater Designation 0.16 to 13) 38(Heater Designation 18 to 32) |
| Rated Short Circuit Breaking Capacity [kA]: 440/460V: Icu | 100(Heater Designation 0.16 to 6.3) 50(Heater Designation 8 to 13) 35(Heater Designation 18 to 32) |
| Rated Short Circuit Breaking Capacity [kA]: 440/460V: Ics | 100(Heater Designation 0.16 to 6.3) 38(Heater Designation 8 to 13) 27(Heater Designation 18 to 32) |
| Rated Short Circuit Breaking Capacity [kA]: 500V: Icu | 100(Heater Designation 0.16 to 6.3) 42(Heater Designation 8 to 13) 10(Heater Designation 18 to 32) |
| Rated Short Circuit Breaking Capacity [kA]: 500V: Ics | 100(Heater Designation 0.16 to 6.3) 32(Heater Designation 8 to 13) 8(Heater Designation 18 to 32) |
| Rated Short Circuit Breaking Capacity [kA]: 600/690V: Icu | 100(Heater Designation 0.16 to 1.6) 8(Heater Designation 2.5 to 4) 6(Heater Designation 6.3 to 13) 4(Heater Designation 18 to 32) |
| Rated Short Circuit Breaking Capacity [kA]: 600/690V: Ics | 100(Heater Designation 0.16 to 1.6) 6(Heater Designation 2.5 to 4) 5(Heater Designation 6.3 to 13) 3(Heater Designation 18 to 32) |
| Category of Use: Selectivity Category | Cat.A |
| Category of Use: Utilization Category | AC-3 |
| Tripping Class: JIS C8201-4-1、IEC60947-4-1 | 10 |
| Instant Tripping Characteristics | 13×Max.le |
| Mechanical Durability [Mil.Times] | 10 |
| Electrical Durability [Mil.Times]: Category AC-3 | 10 |
| Functions: Open-Phase Protection | Yes |
| Functions: Tripping Display | Yes |
| Functions: Test Trip Function | Yes |
| Functions: Terminal Covers | Yes |
| Functions: Wiring Streamlining Terminal | No |
| Mounting Method | IEC rail |
| Terminal Screw Size: Main Circuit | M4 |
More Mitsubishi Electric (Factory Automation) parts
Available on requestMI2532-W Mitsubishi MELIPC
Available on requestMI3315G-W Mitsubishi MELIPC
Available on requestMI3321G-W Mitsubishi MELIPC
Available on requestMI5122-VW Mitsubishi MELIPC
Available on requestMMP-T32BC Mitsubishi Low-voltage switchgear Motor Circuit Breaker
Available on requestMR-ACDL02M Mitsubishi MELSERVO servo Protection coordination cable
Available on requestMR-ACDL05M Mitsubishi MELSERVO servo Protection coordination cable
Available on requestMR-ACN6CBL1M Mitsubishi MELSERVO servo Monitor cable