Honeywell 022630
Escape Route Technology - 1385 Networked Switch Programme Control Terminal Series
- MPN
- 022630
- Category
- Honeywell Access Control
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Honeywell 022630?
The 1385 series includes flush-mounted emergency exit control terminals for complex individual applications and networked applications.They are used to control electric locking elements along escape and rescue routes and are approved according to EltVTR.Stand-alone operation:
Implementation of complex individual applications
Inputs/outputs expandable with I/O module 901-20 (part no. 022644)
Commissioning and configuration via key switch or PC (TSB controller required)Networked operation:
Networkable application for central configuration (FT Manager) and visualization via WINMAG
Networkable via TSB door control BUS controller model 970-30 (part no. 022520.10)Implementation of simple and complex door solutions
Inputs/outputs expandable with I/O module 901-20 (part no. 022644)The emergency exit control units are modular and can be installed in a 2-gang or 3-gang frame. Pre-assembled packages with corresponding frames compatible with the most common switch systems are available.Commissioning and configuration are performed using the key switch.The program is available in a double or triple frame. Please note: A flush-mount power supply must be ordered or quoted separately.The inputs and outputs are available for various functions, such as:
Forwarding defined system states and implementing various control commands for connection to a higher-level building management system.
Connection to adjacent systems such as burglar alarm systems or fire alarm systems.
Integration of other door components such as revolving door operators, electromechanical locks, hold-open devices, and access control systems.
Features & Benefits:Emergency Exit Control Module
Illuminated emergency button with reusable, captive, shatterproof protective cover
Integrated optical door status indicator with symbolically arranged high-performance LEDs (green / red / yellow) for unlocked / locked / alarm
Emergency button warning Label: For double frames: For triple frames:
Self-adhesive label 90x90 mm included
Illuminated warning label module 55x55 mm
Self-adhesive label 90x90 mm not included
Multi-tone signal and tamper contact
Adjustable time sequences for max. permanent release, delayed permanent release, momentary release, pre-alarm, alarm time, orientation signal
Monitoring of door open time during momentary release
1 fire alarm system input
1 configurable input for:
Control of locking/unlocking, momentary release, alarm acknowledgment via a Potential-free contact of operating elements such as card readers, door code devices or similar
Short-term release via access control system or
Emergency unlocking via fire alarm system or
Priority locking via burglar alarm system or
Unlocking via timer, etc.
With a configurable relay output for:
Door locked/unlocked or
Door open/closed or
Collective alarm or
Individual alarm or
Control of door opener/motor lock/revolving door drive/hold-open system
TS bus interface for parameterization via software (FT-Manager) and networking for parallel operation with WINMAG visualization software and control panel
Connections:
SYSCON-4: Power supply
SYSCON-5: Control unit
Screw terminals
Key switch module
For locking/unlocking, momentary unlocking, alarm reset
Tamper contact
With Euro profile half cylinder, including 3 keys
Cover matching the corresponding switch range
Technical data
Integrated control
External power supply required (022605.10)
Networked application via RS-485 TS-BUS controller (022520.11)
Standalone application (Offline operation possible)
Emergency stop switch
Key switch with Euro profile cylinder, adjustable locking bolt 8 x 45°, length 30.5 mm
Setting times and functions via key switch or FT Manager via TS-BUS controller (022520.11)
Input voltage 12-24 V DC
Output voltage 12-24 V DC
Output current for external devices: Max. 2 A (depending on the external power supply)
Current consumption: 0.2 A at 24 V
Operating temperature range: -5 °C to +40 °C
Protection class: IP 30
Dimensions: 2- or 3-gang frame in the switch range, mounting in flush-mounted switch boxes 62.5 mm deep
Inputs: 1 x configurable, plus 1 x fire alarm system
Outputs: 1 x configurable, changeover contact 30 V / 1 A
Key switch can be operated against the direction of escape (without indicator)
Honeywell 022630 — Networked escape door terminals, model 1385, including: 1 x Exit warning sign (or warning sign module in the 3 frame model), 1 x emergency exit control module, 1 x key switch module, 1 x frame. Requires TS-BUS Controller (Model 970). PartnerPLC sources new, surplus and discontinued Honeywell parts — request a quote for price, condition and lead time.
Specifications
Product
| Lifecycle | Active |
Ordering codes
| Part numbers on this product page | 022630, 022631, 022633, 022635, 022637.20, 022638.20, 022640.20, 022642.20, 022643.20 |
No matching specifications
022630: frequently asked questions
When can 022630 be shipped?
022630 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 022630 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 022630 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 022630, subject to availability and destination.