B&R X20PS9600
Power supply module, 24 VDC power supply module for…
- MPN
- X20PS9600
- Category
- System modules for Compact-S PLC
Request a Quote
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- Ships via
What is the B&R X20PS9600?
Supply for Compact-S CPU, X2X Link and internal I/O power supply
Galvanic isolation of supply and CPU / X2X Link power supply
Redundancy of the CPU / X2X Link power supply possible through parallel operation of multiple power supply modules
RS232 configurable as an online interface
CAN bus
The power supply module is used together with an X20 Compact-S PLC. It has a feed for the Compact-S PLC, X2X Link and the internal I/O power supply.
Specifications
Short description
| Power supply module | 24 VDC power supply module for Compact-S PLC, X2X Link power supply and I/O |
| Interfaces | 1x RS232, 1x RS485, 1x CAN bus (note: RS232 interface only in connection with bus module X20BBx2 or X20BBx7. RS485 interface only in connection with bus module X20BB53 or X20BB63. CAN bus only in connection with bus module X20BB57, X20BB67 or X20BB77.) |
General information
| Diagnostics – Module run/error | Yes, using LED status indicator and software |
| Diagnostics – CAN bus data transfer | Yes, using LED status indicator (note: CAN bus only when used with bus module X20BB57, X20BB67 or X20BB77.) |
| Diagnostics – RS232 data transfer | Yes, using LED status indicator (note: RS232 interface only in connection with bus module X20BBx2 or X20BBx7.) |
| Diagnostics – RS485 data transfer | Yes, using LED status indicator (note: RS485 interface only in connection with bus module X20BB53 or X20BB63.) |
| Diagnostics – Overload | Yes, using LED status indicator and software |
| Power consumptionMechanical and electrical configuration" in the X20 system user's manual."> – Internal I/O | 0.6 W (note: The specified values are maximum values. For examples of the exact calculation, see section) |
| Certifications – CE | Yes |
| Certifications – UKCA | Yes |
| Certifications – CRA (Cyber Resilience Act) | In preparation |
| Certifications – ATEX | Zone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X |
| Certifications – UL | cULus E115267; Industrial control equipment |
| Certifications – DNV | Temperature: B (0 to 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck) |
| Certifications – CCS | Yes |
| Certifications – LR | ENV1 |
| Certifications – KR | Yes |
| Certifications – ABS | Yes |
| Certifications – BV | EC33B ; Temperature: 5 - 55°C; Vibration: 4 g; EMC: Bridge and open deck |
| B&R ID code | 0xEB03 |
| Status indicators | Overload, operating state, module status, RS232, RS485, CAN bus (note: RS232 interface only in connection with bus module X20BBx2 or X20BBx7. RS485 interface only in connection with bus module X20BB53 or X20BB63. CAN bus only in connection with bus module X20BB57, X20BB67 or X20BB77.) |
| Power consumption for X2X Link power supplyMechanical and electrical configuration" in the X20 system user's manual."> | 1.42 W (note: The specified values are maximum values. For examples of the exact calculation, see section) |
| Additional power dissipation caused by actuators (resistive) [W] | - |
CPU / X2X Link power supply input
| Input voltage | 24 VDC -15% / +20% |
| Input current | Max. 0.7 A |
| Fuse | Integrated, cannot be replaced |
| Reverse polarity protection | Yes |
CPU / X2X Link power supply output
| Nominal output power | 7 W |
| Parallel connection | Yes (note: In parallel operation, it is only permitted to expect 75% of the nominal power. It is important to make sure that all power supplies operated in parallel are switched on and off at the same time.) |
| Redundant operation | Yes |
| Overload characteristics | Short-circuit proof, temporary overload |
Input I/O power supply
| Input voltage | 24 VDC -15% / +20% |
| Fuse | Required line fuse: Max. 10 A, slow-blow |
| Reverse polarity protection | No |
Output I/O power supply
| Nominal output voltage | 24 VDC |
| Behavior on short circuit | Required line fuse |
| Permissible contact load | 10 A |
Interfaces
| Interface IF1 – Signal | RS232 or RS485 (note: RS232 interface only in connection with bus module X20BBx2 or X20BBx7. RS485 interface only in connection with bus module X20BB53 or X20BB63.) |
| Interface IF1 – Variant | Connection made using 12-pin terminal block X20TB12 |
| Interface IF1 – Transfer rate | Max. 115.2 kbit/s |
| Interface IF3 – Signal | CAN bus (note: CAN bus only in connection with bus module X20BB57, X20BB67 or X20BB77.) |
| Interface IF3 – Variant | Connection made using 12-pin terminal block X20TB12 |
| Interface IF3 – Transfer rate | Max. 1 Mbit/s |
Electrical properties
| Electrical isolation | PLC/X2X Link supply isolated from PLC/X2X Link power supply; I/O supply not isolated from I/O power supply |
Operating conditions
| Mounting orientation – Horizontal | Yes |
| Mounting orientation – Vertical | Yes |
| Installation elevation above sea level – 0 to 2000 m | No limitation |
| Installation elevation above sea level – >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Degree of protection per EN 60529 | IP20 |
Ambient conditions
| Temperature – Horizontal mounting orientation | -25 to 60°C |
| Temperature – Vertical mounting orientation | -25 to 50°C |
| Temperature – Derating | See section "Derating". |
| Temperature – Storage | -40 to 85°C |
| Temperature – Transport | -40 to 85°C |
| Relative humidity – Operation | 5 to 95%, non-condensing |
| Relative humidity – Storage | 5 to 95%, non-condensing |
| Relative humidity – Transport | 5 to 95%, non-condensing |
Mechanical properties
| Note | Order 1x terminal block X20TB12 separately.; Order 1x Compact-S PLC base X20BB5x, X20BB6x or X20BB7x separately. |
| Pitch | 12.5 +0.2 mm |
Accessories
Required accessories (order separately)
| X20cBB57 | System modules for Compact-S PLC — Base for all X20 Compact-S CPUs; RS232 connection; CAN bus connection; Integrated terminating resistor for CAN bus |
| X20cBB52 | System modules for Compact-S PLC — Base for all X20 Compact-S CPUsRS232 connection The bus module is the base for all X20 Compact-S controllers. The left and right end cover… |
| X20BB77 | System modules for Compact-S PLC — Base for X20 Compact-S controllers; 2 slots for X20 interface modules; RS232 connection; CAN bus connection; Integrated terminating resisto… |
| X20BB72 | System modules for Compact-S PLC — Base for X20 Compact-S controllers; 2 slots for X20 interface modules; RS232 connection The bus module is a base for all X20 Compact-S cont… |
| X20BB67 | System modules for Compact-S PLC — Base for X20 Compact-S controllers; 1 slot for X20 interface modules; RS232 connection; CAN bus connection; Integrated terminating resistor… |
| X20BB63 | System modules for Compact-S PLC — Base for X20 Compact-S controllers; 1 slot for X20 interface modules; RS485 connection; Integrated terminating resistor The bus base is a b… |
| X20BB62 | System modules for Compact-S PLC — Base for X20 Compact-S controllers; 1 slot for X20 interface modules; RS232 connection The bus module is the base for all X20CP048x Compact… |
| X20BB57 | System modules for Compact-S PLC — Base for all X20 Compact-S controllers; RS232 connection; CAN bus connection; Integrated terminating resistor for CAN bus The bus module is… |
| X20BB53 | System modules for Compact-S PLC — Base for all X20 Compact-S controllers; RS485 connection; Integrated terminating resistor The bus base is the basis for all X20 Compact-S c… |
| X20BB52 | System modules for Compact-S PLC — Base for all X20 Compact-S controllers; RS232 connection The bus module is the base for all X20 Compact-S controllers. The left and right e… |
| X20TB12 | Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl… |
Downloads & documentation
Official documents from B&R, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
Certificates (11)
- 64331_A1 BV Certificate of Compliance X20
- ABS Certificate of Product Design Assessment - X20 IO Series
- CCS Type Approval Certificate - X20
- E115267 UL Certificate of Compliance X20
- EU Declaration ATEX X20
- EU Declaration of conformity PLC X20
- KR Type Approval Certificate MIL39390-AC003 (X20 System)
- Lloyds Register (X20 only)
- RINA Type Approval Certificate - X20 / Power Panel T30
- TAA00000BJ DNV Type Approval Certificate X20
- UK Declaration PLC X20
X20PS9600: frequently asked questions
When can X20PS9600 be shipped?
X20PS9600 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up X20PS9600 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for X20PS9600 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20PS9600, subject to availability and destination.
More B&R parts