B&R X20cAT2311

I/O module, 2 inputs for Pt100 resistance temperature…

MPN
X20cAT2311
Price and lead time confirmed within 1 business day
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

What happens next
  1. We check stock, condition and lead time
  2. You get a written quote by email
  3. Approve it and we ship — in-stock parts within 1 business day
  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via
  • 100% positive eBay feedback

Have spare B&R parts? We buy surplus →

What is the B&R X20cAT2311?

2 inputs for resistance temperature measurement

PT100 sensor

Direct resistance measurement

4-wire measurement

Configurable filter time

Specifications

Short description

I/O module2 inputs for Pt100 resistance temperature measurement

General information

Diagnostics – Module run/errorYes, using LED status indicator and software
Diagnostics – InputsYes, using LED status indicator and software
Power consumption – Bus0.35 W
Power consumption – Internal I/O0.85 W
Certifications – CEYes
Certifications – UKCAYes
Certifications – CRA (Cyber Resilience Act)In preparation
Certifications – ATEXZone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
Certifications – ULcULus E115267; Industrial control equipment
Certifications – HazLoccCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
Certifications – DNVTemperature: B (0 to 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck)
Certifications – LRENV1
Certifications – KRYes
Certifications – ABSYes
Certifications – BVEC33B ; Temperature: 5 - 55°C; Vibration: 4 g; EMC: Bridge and open deck
B&R ID code0xF3B6
Status indicatorsI/O function per channel, operating state, module status
Additional power dissipation caused by actuators (resistive) [W]-

Resistance measurement temperature inputs

Conversion time – 1000 Hz filter1 ms for all inputs
Conversion time – 50 Hz filter20 ms for all inputs
Max. error at 25°C – Gain±0.0059% (note: To guarantee accuracy, dummy module ZF0000 must be connected to the left and right of module AT2311.)
Max. error at 25°C – Offset±0.0015% (note: To guarantee accuracy, dummy module ZF0000 must be connected to the left and right of module AT2311.)
Temperature measurement monitoring – Range undershoot0x80000001
Temperature measurement monitoring – Range overshoot0x7FFFFFFF
Temperature measurement monitoring – Open circuit0x7FFFFFFF
Temperature measurement monitoring – General fault0x80000000
Temperature measurement monitoring – Open inputs0x7FFFFFFF
Resistance measurement monitoring – Range undershoot0x80000001
Resistance measurement monitoring – Range overshoot0xFFFFFFFF
Resistance measurement monitoring – Open circuit0xFFFFFFFF
Resistance measurement monitoring – General fault0x80000000
InputResistance measurement with constant current supply for 4-wire connections
Digital converter resolution24-bit
Filter timeConfigurable between 1 ms and 400 ms
Conversion procedureSigma-delta
Output formatDINT or UDINT for resistance measurement
Temperature measurement range-200 to 850°C
Resistance measurement range0.5 to 390 Ω
Temperature sensor resolution1 LSB = 0.001°C
Resistance measurement resolution0.001 Ω
Input filterFirst-order low-pass filter / cutoff frequency 1050 Hz
Sensor standardEN 60751
Insulation voltage between channel and bus500 V eff
Insulation voltage between channel and channel500 V eff
Linearization methodInternal
Measuring current1 mA
Temperature sensor normalization-200.0 to 850.0°C
Reference1568 Ω ±0.1%
Permissible input signalShort-term max. 28.8 V
Max. gain drift±0.00065%/°C (note: Based on the current measured resistance value.)
Max. offset drift±0.000025%/°C (note: Based on the entire resistance measurement range.)
Nonlinearity<0.001% (note: Based on the entire resistance measurement range.)
Standardized range of values for resistance measurement0.5 Ω to 390 Ω

Electrical properties

Electrical isolationChannel isolated from channel and bus

Operating conditions

Mounting orientation – HorizontalYes
Mounting orientation – VerticalYes
Installation elevation above sea level – 0 to 2000 mNo limitation
Installation elevation above sea level – >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20

Ambient conditions

Temperature – Horizontal mounting orientation-25 to 60°C
Temperature – Vertical mounting orientation-25 to 50°C
Temperature – Derating-
Temperature – Storage-40 to 85°C
Temperature – Transport-40 to 85°C
Relative humidity – OperationUp to 100%, condensing
Relative humidity – Storage5 to 95%, non-condensing
Relative humidity – Transport5 to 95%, non-condensing

Mechanical properties

NoteOrder 1x terminal block X20TB12 separately.; Order 1x bus module X20cBM11 separately.
Pitch12.5 +0.2 mm

Accessories

Required accessories (order separately)

X20cBM11Bus modules — Bus module for 24 VDC I/O modules; The internal I/O power supply is connected through.
X20TB12Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl…

X20cAT2311: frequently asked questions

When can X20cAT2311 be shipped?

X20cAT2311 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up X20cAT2311 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for X20cAT2311 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20cAT2311, subject to availability and destination.

More B&R parts

B&R X20cAO4632 – I/O module, 4 analog outputs ±10 V or 0 to 20 mA
B&R
X20cAO4632

I/O module, 4 analog outputs ±10 V or 0 to 20 mA

B&R X20cAO4632-1 – I/O module, 4 analog outputs ±11 V or 0 to 22 mA
B&R
X20cAO4632-1

I/O module, 4 analog outputs ±11 V or 0 to 22 mA

B&R X20cAP3121 – I/O module, 3-phase power and energy metering module for…
B&R
X20cAP3121

I/O module, 3-phase power and energy metering module for…

B&R X20cAP3131 – I/O module, 3-phase power and energy metering module for…
B&R
X20cAP3131

I/O module, 3-phase power and energy metering module for…

B&R X20cAT4222 – I/O module, 4 inputs for Pt100 or Pt1000 resistance…
B&R
X20cAT4222

I/O module, 4 inputs for Pt100 or Pt1000 resistance…

B&R X20cAT6402 – I/O module, 6 inputs for thermocouples
B&R
X20cAT6402

I/O module, 6 inputs for thermocouples

B&R X20cBB52 – Bus module, X20 Compact-S PLC base - backplane for…
B&R
X20cBB52

Bus module, X20 Compact-S PLC base - backplane for…

B&R X20cBB57 – Bus module, X20 Compact-S PLC base - backplane for…
B&R
X20cBB57

Bus module, X20 Compact-S PLC base - backplane for…

B&R X20cAT2311Price and lead time confirmed within 1 business day
Request a Quote