B&R X20AO2437

I/O module, 2 analog outputs 4 to 20 mA

MPN
X20AO2437
Price and lead time confirmed within 1 business day
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • Ships via

What is the B&R X20AO2437?

2 analog current outputs

Electrically isolated analog channels

16-bit digital converter resolution

The module is equipped with 2 current outputs with 16-bit digital converter resolution. The 2 channels are electrically isolated from each other. The user can select between the 3 output ranges 4 to 20 mA , 0 to 20 mA and 0 to 24 mA .

Specifications

Short description

I/O module2 analog outputs 4 to 20 mA, 0 to 20 mA or 0 to 24 mA

General information

Diagnostics – Module run/errorYes, using LED status indicator and software
Diagnostics – OutputsYes, using LED status indicator and software
Power consumption – Bus0.05 W
Power consumption – Internal I/O1.6 W
Certifications – CEYes
Certifications – UKCAYes
Certifications – CRA (Cyber Resilience Act)In preparation
Certifications – ATEXZone 2, II 3G Ex nA nC IIA T5 Gc; IP20, Ta (see X20 user's manual); FTZÚ 09 ATEX 0083X
Certifications – ULcULus E115267; Industrial control equipment
Certifications – HazLoccCSAus 244665; Process control equipment; for hazardous locations; Class I, Division 2, Groups ABCD, T5
Certifications – DNVTemperature: B (0 to 55°C); Humidity: B (up to 100%); Vibration: B (4 g); EMC: B (bridge and open deck)
Certifications – CCSYes
Certifications – LRENV1
Certifications – KRYes
Certifications – ABSYes
Certifications – BVEC33B ; Temperature: 5 - 55°C; Vibration: 4 g; EMC: Bridge and open deck
Certifications – KCYes
B&R ID code0xB785
Status indicatorsI/O function per channel, operating state, module status
Additional power dissipation caused by actuators (resistive) [W]-

Analog outputs

Max. error – 4 to 20 mA±0.025% (note: At 25°C)
Max. error – 0 to 20 mA±0.022% (note: At 25°C)
Max. error – 0 to 24 mA±0.02% (note: At 25°C)
Max. error – 4 to 20 mA±0.025% (note: At 25°C)
Max. error – 0 to 20 mA±0.022% (note: At 25°C)
Max. error – 0 to 24 mA±0.02% (note: At 25°C)
Output format – 4 to 20 mAINT 0x0000 to 0x7FFF / 1 LSB = 0x0001 = 488.281 nA
Output format – 0 to 20 mAINT 0x0000 to 0x7FFF / 1 LSB = 0x0001 = 610.352 nA ; UINT 0x0000 to 0xFFFF / 1 LSB = 0x0001 = 305.176 nA
Output format – 0 to 24 mAINT 0x0000 to 0x5DC0 / 1 LSB = 0x0001 = 1000 nA
Max. gain drift – 4 to 20 mA±0.0055%/°C (note: Based on the current output value.)
Max. gain drift – 0 to 20 mA±0.005%/°C (note: Based on the current output value.)
Max. gain drift – 0 to 24 mA±0.005%/°C (note: Based on the current output value.)
Max. offset drift – 4 to 20 mA±0.0035%/°C (note: Based on the respective output range.)
Max. offset drift – 0 to 20 mA±0.002%/°C (note: Based on the respective output range.)
Max. offset drift – 0 to 24 mA±0.002%/°C (note: Based on the respective output range.)
Error caused by load change – 4 to 20 mA0.14% (note: Load change from 1 Ω → 600 Ω, resistive)
Error caused by load change – 0 to 20 mA0.1% (note: Load change from 1 Ω → 600 Ω, resistive)
Error caused by load change – 0 to 24 mA0.1% (note: Load change from 1 Ω → 600 Ω, resistive)
Test voltage – Channel - Channel1000 VAC
Test voltage – Channel - Bus1000 VAC
Test voltage – Channel - Ground1000 VAC
Output4 to 20 mA, 0 to 20 mA or 0 to 24 mA configurable using software
Digital converter resolution16-bit
Settling time on output change over entire range2 ms to 20 s, configurable using software
Data output rate1 ms without ramp
Output protectionShort-circuit proof, overvoltage protection (up to 30 VDC)
Open-circuit detectionYes, using hardware and software
Data formatINT
Load per channelMax. 600 Ω
Short-circuit proofYes, continuous
Output filterActive second-order low-pass filter / Cutoff frequency 4 kHz; Configurable slew rate
Nonlinearity<0.003% (note: Based on the entire output range.)

Electrical properties

Electrical isolationChannel isolated from channel and bus

Operating conditions

Mounting orientation – HorizontalYes
Mounting orientation – VerticalYes
Installation elevation above sea level – 0 to 2000 mNo limitation
Installation elevation above sea level – >2000 mReduction of ambient temperature by 0.5°C per 100 m
Degree of protection per EN 60529IP20

Ambient conditions

Temperature – Horizontal mounting orientation-25 to 60°C
Temperature – Vertical mounting orientation-25 to 50°C
Temperature – DeratingSee section "Derating".
Temperature – Storage-40 to 85°C
Temperature – Transport-40 to 85°C
Relative humidity – Operation5 to 95%, non-condensing
Relative humidity – Storage5 to 95%, non-condensing
Relative humidity – Transport5 to 95%, non-condensing

Mechanical properties

NoteOrder 1x terminal block X20TB12 separately. ; Order 1x bus module X20BM11 separately.
Pitch12.5 +0.2 mm

Accessories

Required accessories (order separately)

X20BM15Bus modules — The bus module is the base for all X20 24 VDC I/O modules; The internal I/O supply is interconnected; Manual node number assignment; Indepe…
X20BM11Bus modules — Bus module for 24 VDC I/O modules; The internal I/O power supply is connected through. The bus module is the base for all 24 VDC I/O module…
X20TB12Terminal blocks — Tool-free wiring with push-in technology; Simple wire release using lever; Ability to label each terminal; Plain text labeling also possibl…

Downloads & documentation

Official documents from B&R, downloaded directly from the manufacturer.

Data sheets & manuals

CAD & dimension drawings

Certificates (15)

X20AO2437: frequently asked questions

When can X20AO2437 be shipped?

X20AO2437 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up X20AO2437 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for X20AO2437 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for X20AO2437, subject to availability and destination.

More B&R parts

B&R X20AI8221 – I/O module, 8 analog inputs ±10 V
B&R
X20AI8221

I/O module, 8 analog inputs ±10 V

B&R X20AI8321 – I/O module, 8 analog inputs 0 to 20 mA / 4 to 20 mA
B&R
X20AI8321

I/O module, 8 analog inputs 0 to 20 mA / 4 to 20 mA

B&R X20AIA744 – I/O module, 2 full-bridge strain gauge inputs
B&R
X20AIA744

I/O module, 2 full-bridge strain gauge inputs

B&R X20AIB744 – I/O module, 4 full-bridge strain gauge inputs
B&R
X20AIB744

I/O module, 4 full-bridge strain gauge inputs

B&R X20AO2438 – I/O module, 2 analog outputs 4 to 20 mA
B&R
X20AO2438

I/O module, 2 analog outputs 4 to 20 mA

B&R X20AO2622 – I/O module, 2 analog outputs ±10 V or 0 to 20 mA / 4 to 20…
B&R
X20AO2622

I/O module, 2 analog outputs ±10 V or 0 to 20 mA / 4 to 20…

B&R X20AO2632 – I/O module, 2 analog outputs ±10 V or 0 to 20 mA
B&R
X20AO2632

I/O module, 2 analog outputs ±10 V or 0 to 20 mA

B&R X20AO2632-1 – I/O module, 2 analog outputs ±11 V or 0 to 22 mA
B&R
X20AO2632-1

I/O module, 2 analog outputs ±11 V or 0 to 22 mA

B&R X20AO2437Price and lead time confirmed within 1 business day
Request a Quote