What is the Beckhoff EL1252-0010?

The EL1252-0010 digital input terminal acquires the fast binary 24 V control signals from the process level and transmits them, in an electrically isolated form, to the controller. The EtherCAT Terminal contains two channels whose signal state is

Specifications

Specifications

Connection technology4-wire
Specificationsimilar to EN 61131-2, type 3, “0”: -3…5 V DC, “1”: 11…30 V DC, typ. 3 mA input current
Number of inputs2
Nominal voltage24 V DC (-15%/+20%)
“0” signal voltage-3…+5 V (similar to EN 61131-2, type 3)
“1” signal voltage11…30 V (similar to EN 61131-2, type 3)
Input currenttyp. 3 mA (similar to EN 61131-2, type 3)
Input filtertyp. 10 µs
Resolution timestamp1 ns
Precision of timestamp in the terminal10 ns (+ input delay)
Input delay TON/TOFF1 µs
Distributed clocksyes
Distributed clock precision1 µs
Time resolution signal1 ns
Current consumption power contactstyp. 6 mA + load
Current consumption E-bustyp. 110 mA
Electrical isolation500 V (E-bus/field potential)
Bit width in the process image2 x input + 2 x 16 byte timestamp
Configurationno address or configuration setting
Special featurestimestamping, latch last edge
Weightapprox. 55 g
Operating temperature0…55°C
Storage temperature-25…+85°C
Relative humidity95%, no condensation
Vibration/shock resistanceconforms to EN 60068-2-6/EN 60068-2-27
EMC immunity/emissionconforms to EN 61000-6-2/EN 61000-6-4
Protect. rating/installation pos.IP20/variable
Pluggable wiringfor all ESxxxx terminals
Approvals/markingsCE, CCC, UL, ATEX, IECEx
Ex markingATEX: II 3 G Ex ec IIC T4 Gc IECEx: Ex ec IIC T4 Gc
Design formcompact terminal housing with signal LEDs
Materialpolycarbonate
Installationon 35 mm DIN rail, conforming to EN 60715 with lock
Side by side mounting by means ofdouble slot and key connection
Markinglabeling of the BZxxxx series
Wiringsolid conductor (s), flexible conductor (st) and ferrule (f): spring actuation by screwdriver
Connection cross-sections*: 0.08…2.5 mm², st*: 0.08…2.5 mm², f*: 0.14…1.5 mm²
Connection cross-section AWGs*: AWG28…14, st*: AWG28…14, f*: AWG26…16
Stripping length8…9 mm
Current load power contactsImax: 10 A
Dimensions (W x H x D)12 mm x 100 mm x 68 mm

EL1252-0010: frequently asked questions

When can EL1252-0010 be shipped?

EL1252-0010 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up EL1252-0010 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for EL1252-0010 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for EL1252-0010, subject to availability and destination.

More Beckhoff parts

Beckhoff EL1134 – EtherCAT Terminal, 4-channel digital input, 48 V DC, 10 µs
Beckhoff
EL1134

EtherCAT Terminal, 4-channel digital input, 48 V DC, 10 µs

Beckhoff EL1144 – EtherCAT Terminal, 4-channel digital input, 12 V DC, 10 µs
Beckhoff
EL1144

EtherCAT Terminal, 4-channel digital input, 12 V DC, 10 µs

Beckhoff EL1202 – EtherCAT Terminal, 2-channel digital input, 24 V DC, 1 µs
Beckhoff
EL1202

EtherCAT Terminal, 2-channel digital input, 24 V DC, 1 µs

Beckhoff EL1252 – EtherCAT Terminal, 2-channel digital input, 24 V DC, 1 µs, timestamp
Beckhoff
EL1252

EtherCAT Terminal, 2-channel digital input, 24 V DC, 1 µs, timestamp

Beckhoff EL1252-0050 – EtherCAT Terminal, 2-channel digital input, 5 V DC, 1 µs, timestamp
Beckhoff
EL1252-0050

EtherCAT Terminal, 2-channel digital input, 5 V DC, 1 µs, timestamp

Beckhoff EL1252-0060 – EtherCAT Terminal, 2-channel digital input, 10 V DC, 1 µs, timestamp
Beckhoff
EL1252-0060

EtherCAT Terminal, 2-channel digital input, 10 V DC, 1 µs, timestamp

Beckhoff EL1254 – EtherCAT Terminal, 4-channel digital input, 24 V DC, 1 µs, timestamp
Beckhoff
EL1254

EtherCAT Terminal, 4-channel digital input, 24 V DC, 1 µs, timestamp

Beckhoff EL1258 – EtherCAT Terminal, 8-channel digital input, 24 V DC, 1 µs, multi-timestamp
Beckhoff
EL1258

EtherCAT Terminal, 8-channel digital input, 24 V DC, 1 µs, multi-timestamp

Beckhoff EL1252-0010Price and lead time confirmed within 1 business day
Request a Quote