EtherCAT plug-in module, 1-channel encoder interface, incremental, 5 V DC (DIFF RS422, TTL), 1 MHz, TwinSAFE SC
EtherCAT plug-in module, 2-channel communication interface, serial, RS232/RS422/RS485
The EJ6002 EtherCAT plug-in module enables the connection of devices with two RS232, RS485 or RS422 interfaces. Apart from the convenient selection of the communication standard (RS232, RS485 or RS422) using the TwinCAT software, various operation modes
| Technology | serial interface |
| Interfaces | individually selectable from RS232, RS485, RS422 |
| Data transfer channels | 2 |
| Data transfer rates | 300…256,000 baud (individual free configurable) |
| Data buffer | 864 bytes receive buffer, 128 bytes transmit buffer |
| Current consumption E-bus | 190 mA |
| Electrical isolation | 500 V (E-bus/field potential) |
| Weight | approx. 30 g |
| Operating temperature | -25…+60°C |
| Storage temperature | -40…+85°C |
| Relative humidity | 95%, no condensation |
| EMC immunity/emission | conforms to EN 61000-6-2/EN 61000-6-4 |
| Protect. rating/installation pos. | IP20/see documentation |
| Vibration/shock resistance | conforms to EN 60068-2-6/EN 60068-2-27 |
| Approvals/markings | CE, UL |
| Design form | EtherCAT I/O plug-in module |
| Material | polycarbonate |
| Installation | on signal distribution board |
| Mechanical coding | EJ plug-in module: signal-specific coding pins on the housing, signal distribution board: holes in the printed circuit board |
| Position of the coding pins | 2, 5 |
| Locking | latching lug in circuit board cut-out |
| Connection method | field wiring: application-specific wiring level on the signal distribution board, EJ plug-in module: 2 x 20-pin socket strip |
| Dimensions (W x H x D) | 12 mm x 66 mm x 55 mm |
EJ6002 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Yes — mention it when you request a quote for EJ6002 and we'll include express shipping options in our reply.
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for EJ6002, subject to availability and destination.

EtherCAT plug-in module, 1-channel encoder interface, incremental, 5 V DC (DIFF RS422, TTL), 1 MHz, TwinSAFE SC

EtherCAT plug-in module, 2-channel encoder interface, incremental, 5 V DC (DIFF RS422, TTL, open collector), 5 MHz, 2 x AB/1 x ABC

EtherCAT plug-in module, 1-channel encoder interface, incremental, 24 V DC HTL, 100 kHz

EtherCAT plug-in module, 2-channel encoder interface, incremental, 24 V DC HTL, 100 kHz




EtherCAT plug-in module, 4-channel communication interface, IO-Link, master, TwinSAFE SC