ABB 1SBL931074R8110 – AX25-30-10-81 24V 50/60Hz Contactor
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | ABB AX Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.326 kg |
| Country of origin | India |
| UPC / EAN | 3471522397812 |
Shipping & availability
When can 1SBL931074R8110 be shipped?
1SBL931074R8110 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SBL931074R8110 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SBL931074R8110 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBL931074R8110, subject to availability and destination.
AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Specifications
General
| Order code (ABB product ID) | 1SBL931074R8110 |
| Type | AX25-30-10-81 |
| Lifecycle | Active (current ABB product) |
| Country of origin | India |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 44 mm |
| Product Net Depth / Length | 74 mm |
| Product Net Height | 76.3 mm |
| Product Net Weight | 0.326 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Rated Operational Voltage | Auxiliary Circuit 690 V, Main Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 32 A, acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (220 / 240 V) 55 °C 27 A, (690 V) 40 °C 32 A, (690 V) 70 °C 23 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 55 °C 25 A, (440 V) 55 °C 16 A, (500 V) 55 °C 14 A, (690 V) 55 °C 10 A, (380 / 400 V) 55 °C 25 A, (220 / 230 / 240 V) 55 °C 25 A |
| Rated Operational Current AC-15 (I<sub>e</sub>) | (500 V) NC 2, (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (380 / 400 V) 3 A, (400 / 440 V) 2 A |
| Rated Operational Current DC-13 (I<sub>e</sub>) | (24 V) 6 A / 144 W, (110 V) 1.1 A / 121 W, (125 V) 1.1 A / 138 W, (220 V) 0.55 A / 121 W, (250 V) 0.55 A / 138 W, (400 V) 2.8 A / 134 W, (500 V) 2 A / 144 W |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 11 kW, (440 V) 9 kW, (500 V) 9 kW, (690 V) 9 kW, (380 / 400 V) 11 kW, (220 / 230 / 240 V) 6.5 kW |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 200 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 32 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 85 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 105 A, for 0.1 s 140 A, for 1 s 100 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-15) 1200 cycles per hour, (AC-3) 1200 cycles per hour, (DC-13) 900 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 24 V, 60 Hz 24 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 12 V·A, Average Holding Value 50 Hz 12 V·A, Average Holding Value 60 Hz 12 V·A, Average Holding Value, from Warm State 3 W, Average Pull-in Value 50 Hz 120 V·A, Average Pull-in Value 60 Hz 140 V·A |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 1.2 W, at Rated Operating Conditions AC-3 per Pole 0.35 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 9 ... 16 ms, Between Coil De-energization and NO Contact Opening 4 ... 11 ms, Between Coil Energization and NC Contact Opening 7 ... 21 ms, Between Coil Energization and NO Contact Closing 10 ... 26 ms |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
| Tightening Torque | Auxiliary Circuit 1 N·m, Control Circuit 1 N·m, Main Circuit 1.2 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
Technical UL/CSA
| General Use Rating UL/CSA | (600 V AC) 30 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 2 hp, (200 ... 208 V AC) Three Phase 7.5 hp, (220 ... 240 V AC) Three Phase 7.5, (240 V AC) Single Phase 3 hp, (440 ... 480 V AC) Three Phase 15 hp, (550 ... 600 V AC) Three Phase 15 hp |
| Tightening Torque UL/CSA | Auxiliary Circuit 9 in·lb, Control Circuit 9 in·lb, Main Circuit 11 in·lb |
| Full Load Amps Motor Use | (120 V AC) Single Phase 24 A, (200 ... 208 V AC) Three Phase 25.3 A, (220 ... 240 V AC) Three Phase 22 A, (240 V AC) Single Phase 17 A, (440 ... 480 V AC) Three Phase 21 A, (550 ... 600 V AC) Three Phase 17 A |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... 70 °C |
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 169ab428-19ae-470c-8a6e-e7cbeaeff0dd Bulgaria |
| Simplified SCIP | 02f1baba-f87e-40db-9496-124a3acfe83d Denmark, 0453fb03-634f-4eb6-a661-51d7f627e1da Greece, 06562eac-9447-41b9-b288-2f054e4b9aeb Hungary, 09d2c8c3-96a1-47bc-b402-9f15c36f7845 Germany, 116a93cd-383a-4e8a-ad57-679c4f64365b Germany, 1bbf0537-03a1-4075-9767-e4a9b4e79694 Finland, 31a8d9ed-6ce3-4956-9b48-4d5e80388992 Sweden, 469f7451-7375-44d3-bf84-1fb303d53732 France, 49dad115-3e1a-4d92-a39c-57e9b1181de0 Estonia, 4b95733d-8ecc-4c58-8cce-6c068f5d5a0a France, 599eed60-de2c-4d62-9a8d-f1fa1943c7f5 Belgium, 60e083de-a28b-4c3b-88c5-86635da35546 Spain, 64468e69-e690-4393-8e2a-4af863fac0df Hungary, 67487805-5070-4d64-be0b-edc066c57910 Czechia, 721571a8-facc-4f42-a6b3-7c74ad3b6676 Poland, 794af59d-4397-408f-b1fa-14f77f09ddb0 Poland, 848d8189-75b4-4df4-aad4-e3273b9a216c Norway, 8bb7e1fe-f33a-4ce7-8ba7-9e93821b312f Germany, 96893890-1ec9-4bf9-b3cc-5943e9e03fdb Belgium, b35c3f4c-492a-453b-9649-e7bad5980ab6 Croatia, d0937855-1cdc-43cb-a5ef-2c7ac0f1d969 Sweden, d59f143b-0bc3-4636-8e37-952f6262595f Netherlands, e2fb786c-4c29-4915-87eb-91c23a8d9a8e Portugal, e5cf04f2-ca84-4389-8925-803c52367931 Germany, e8de6085-4049-4d61-b9d1-59fcbc190b3e Italy, ee848b5f-dac6-4ed5-be4c-daf89016ec7e Poland, fc7d6d2b-223d-44ea-9bc1-455cb9385091 Germany |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
| E-Number (Finland) | 3707336 |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
| Data Sheet, Technical Information (1SBC100187L0203) | |
| Instructions and Manuals (9AKK107492A7057) |
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (8)
More ABB parts
Available on requestAX25-30-10-75 200V50HZ/200-220V60HZ Contactor
Available on requestAX25-30-01-80 220-230V50Hz/230-240V60Hz Contactor
Available on requestAX25-30-10-80 220-230V50Hz/230-240V60Hz Contactor
Available on requestAX25-30-01-81 24V 50/60Hz Contactor
Available on requestAX25-30-01-83 48V 50/60Hz Contactor
Available on requestAX25-30-10-83 48V 50/60Hz Contactor
Available on requestAX25-30-01-84 110V50Hz/110-120V60Hz Contactor
Available on requestAX25-30-10-84 110V50Hz/110-120V60Hz Contactor