| Availability | Confirmed on request |
| Category | ABB AX Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.326 kg |
| Country of origin | India |
| UPC / EAN | 3471522398819 |
Shipping & availability
When can 1SBL931074R8101 be shipped?
1SBL931074R8101 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SBL931074R8101 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SBL931074R8101 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBL931074R8101, subject to availability and destination.
AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Specifications
General
| Order code (ABB product ID) | 1SBL931074R8101 |
| Type | AX25-30-01-81 |
| Lifecycle | Active (current ABB product) |
| Country of origin | India |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 44 mm |
| Product Net Depth / Length | 74 mm |
| Product Net Height | 76.3 mm |
| Product Net Weight | 0.326 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Auxiliary Circuit 690 V, Main Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 32 A, acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (220 / 240 V) 55 °C 27 A, (690 V) 40 °C 32 A, (690 V) 70 °C 23 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 55 °C 25 A, (440 V) 55 °C 16 A, (500 V) 55 °C 14 A, (690 V) 55 °C 10 A, (380 / 400 V) 55 °C 25 A, (220 / 230 / 240 V) 55 °C 25 A |
| Rated Operational Current AC-15 (I<sub>e</sub>) | (500 V) NC 2, (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (380 / 400 V) 3 A, (400 / 440 V) 2 A |
| Rated Operational Current DC-13 (I<sub>e</sub>) | (24 V) 6 A / 144 W, (110 V) 1.1 A / 121 W, (125 V) 1.1 A / 138 W, (220 V) 0.55 A / 121 W, (250 V) 0.55 A / 138 W, (400 V) 2.8 A / 134 W, (500 V) 2 A / 144 W |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 11 kW, (440 V) 9 kW, (500 V) 9 kW, (690 V) 9 kW, (380 / 400 V) 11 kW, (220 / 230 / 240 V) 6.5 kW |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 200 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 32 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 85 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 105 A, for 0.1 s 140 A, for 1 s 100 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-15) 1200 cycles per hour, (AC-3) 1200 cycles per hour, (DC-13) 900 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 24 V, 60 Hz 24 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 12 V·A, Average Holding Value 50 Hz 12 V·A, Average Holding Value 60 Hz 12 V·A, Average Holding Value, from Warm State 3 W, Average Pull-in Value 50 Hz 120 V·A, Average Pull-in Value 60 Hz 140 V·A |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 1.2 W, at Rated Operating Conditions AC-3 per Pole 0.35 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 9 ... 16 ms, Between Coil De-energization and NO Contact Opening 4 ... 11 ms, Between Coil Energization and NC Contact Opening 7 ... 21 ms, Between Coil Energization and NO Contact Closing 10 ... 26 ms |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
| Tightening Torque | Auxiliary Circuit 1 N·m, Control Circuit 1 N·m, Main Circuit 1.2 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
Technical UL/CSA
| General Use Rating UL/CSA | (600 V AC) 30 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 2 hp, (200 ... 208 V AC) Three Phase 7.5 hp, (220 ... 240 V AC) Three Phase 7.5, (240 V AC) Single Phase 3 hp, (440 ... 480 V AC) Three Phase 15 hp, (550 ... 600 V AC) Three Phase 15 hp |
| Tightening Torque UL/CSA | Auxiliary Circuit 9 in·lb, Control Circuit 9 in·lb, Main Circuit 11 in·lb |
| Full Load Amps Motor Use | (120 V AC) Single Phase 24 A, (200 ... 208 V AC) Three Phase 25.3 A, (220 ... 240 V AC) Three Phase 22 A, (240 V AC) Single Phase 17 A, (440 ... 480 V AC) Three Phase 21 A, (550 ... 600 V AC) Three Phase 17 A |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... 70 °C |
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 8f3b472d-5f1a-4737-bdc7-a72e782198aa Bulgaria |
| Simplified SCIP | 0ad2a911-1af7-428e-b4dd-e10da7afa0c1 Portugal, 1f7e231b-6af9-4a9f-ac64-ae3a94b2b37b Finland, 2979e931-67c6-4b0d-99ec-82be9ed717c6 Sweden, 2dffa079-ebd1-4ebc-b9ee-a7c3fbb3a1ff Hungary, 32857b2c-7e48-477b-9be4-c9c2f2e65c4a Germany, 3f8518a3-05e4-413c-8b28-65eee31558f1 Sweden, 408d4c17-149c-49c9-8d5e-682cea2e680c Poland, 4b1b14be-e57b-48c9-84b6-64d5a7489e8c Estonia, 4f82fb0a-745b-4aed-b086-930197df05bc Germany, 89d9ad04-2ae6-45ea-b737-44521dc58890 Poland, 8acac8d3-6ce7-41b2-a801-a0cef0962dca Czechia, 90cbb2d2-726b-4759-9a7d-a7973222995e Germany, 95c0bdf9-4e41-4f7b-a5e3-57626d8108dc Greece, a70094b7-1bae-4865-ba61-4e0db04195f7 Spain, a83354a2-c7d3-4fc1-a3fc-0c3709b9531a Poland, ac8ebb61-62e4-479b-9346-09da7b6b83a1 Netherlands, bd2b5446-3e9b-4604-ad8d-62ec386a22b6 France, cae76f4d-e546-4e14-be9a-b9cb6dd5cee3 Hungary, cd7e2d51-f1d4-4080-bab6-2d122163680e Belgium, cf3beb8d-7690-46fe-b4ff-06e32ba7f40d France, d0d77f0c-dec1-4c5c-82af-e9d99e00fa58 Belgium, d8389cbf-0e4c-418b-9ec2-48ff79cec41a Germany, ddae8409-8eb8-424c-90dc-f19921bd8c4b Denmark, e6bd22e9-23bb-4e2e-ad3e-1ba7b592ff34 Croatia, eb1394d1-3184-4161-89b5-068ce647a233 Norway, f5b4f73b-a28f-4717-97cb-5417e56aa822 Germany, f701668f-8141-4c34-8c8f-633f700de956 Italy |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
| E-Number (Finland) | 3707331 |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
| Data Sheet, Technical Information (1SBC100187L0203) | |
| Instructions and Manuals (9AKK107492A7057) |
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (8)
More ABB parts
Available on requestAX25-30-01-75 200V50HZ/200-220V60HZ Contactor
Available on requestAX25-30-10-75 200V50HZ/200-220V60HZ Contactor
Available on requestAX25-30-01-80 220-230V50Hz/230-240V60Hz Contactor
Available on requestAX25-30-10-80 220-230V50Hz/230-240V60Hz Contactor
Available on requestAX25-30-10-81 24V 50/60Hz Contactor
Available on requestAX25-30-01-83 48V 50/60Hz Contactor
Available on requestAX25-30-10-83 48V 50/60Hz Contactor
Available on requestAX25-30-01-84 110V50Hz/110-120V60Hz Contactor