Quick facts
| Availability | Confirmed on request |
| Category | ABB AX Contactors |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.326 kg |
| Country of origin | India |
| UPC / EAN | 3471522398802 |
Shipping & availability
When can 1SBL931074R8001 be shipped?
1SBL931074R8001 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 1SBL931074R8001 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 1SBL931074R8001 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 1SBL931074R8001, subject to availability and destination.
AX09...AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Specifications
General
| Order code (ABB product ID) | 1SBL931074R8001 |
| Type | AX25-30-01-80 |
| Lifecycle | Active (current ABB product) |
| Country of origin | India |
Ordering
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
Dimensions
| Product Net Width | 44 mm |
| Product Net Depth / Length | 74 mm |
| Product Net Height | 76.3 mm |
| Product Net Weight | 0.326 kg |
Technical
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Auxiliary Circuit 690 V, Main Circuit 690 V |
| Rated Frequency (f) | Auxiliary Circuit 50 / 60 Hz, Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I<sub>th</sub>) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 32 A, acc. to IEC 60947-5-1, Θ = 40 °C 16 A |
| Rated Operational Current AC-1 (I<sub>e</sub>) | (220 / 240 V) 55 °C 27 A, (690 V) 40 °C 32 A, (690 V) 70 °C 23 A |
| Rated Operational Current AC-3 (I<sub>e</sub>) | (415 V) 55 °C 25 A, (440 V) 55 °C 16 A, (500 V) 55 °C 14 A, (690 V) 55 °C 10 A, (380 / 400 V) 55 °C 25 A, (220 / 230 / 240 V) 55 °C 25 A |
| Rated Operational Current AC-15 (I<sub>e</sub>) | (500 V) NC 2, (500 V) 2 A, (690 V) 2 A, (24 / 127 V) 6 A, (220 / 240 V) 4 A, (380 / 400 V) 3 A, (400 / 440 V) 2 A |
| Rated Operational Current DC-13 (I<sub>e</sub>) | (24 V) 6 A / 144 W, (110 V) 1.1 A / 121 W, (125 V) 1.1 A / 138 W, (220 V) 0.55 A / 121 W, (250 V) 0.55 A / 138 W, (400 V) 2.8 A / 134 W, (500 V) 2 A / 144 W |
| Rated Operational Power AC-3 (P<sub>e</sub>) | (415 V) 11 kW, (440 V) 9 kW, (500 V) 9 kW, (690 V) 9 kW, (380 / 400 V) 11 kW, (220 / 230 / 240 V) 6.5 kW |
| Rated Short-time Withstand Current Low Voltage (I<sub>cw</sub>) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 200 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 32 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 85 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 105 A, for 0.1 s 140 A, for 1 s 100 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A, cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A |
| Rated Insulation Voltage (U<sub>i</sub>) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V |
| Rated Impulse Withstand Voltage (U<sub>imp</sub>) | Auxiliary Circuit 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour, (AC-15) 1200 cycles per hour, (AC-3) 1200 cycles per hour, (DC-13) 900 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (U<sub>c</sub>) | 50 Hz 220 ... 230 V, 60 Hz 230 ... 240 V |
| Coil Consumption | Average Holding Value 50 / 60 Hz 12 V·A, Average Holding Value 50 Hz 12 V·A, Average Holding Value 60 Hz 12 V·A, Average Holding Value, from Warm State 3 W, Average Pull-in Value 50 Hz 120 V·A, Average Pull-in Value 60 Hz 140 V·A |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 1.2 W, at Rated Operating Conditions AC-3 per Pole 0.35 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 9 ... 16 ms, Between Coil De-energization and NO Contact Opening 4 ... 11 ms, Between Coil Energization and NC Contact Opening 7 ... 21 ms, Between Coil Energization and NO Contact Closing 10 ... 26 ms |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20, acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 |
| Tightening Torque | Auxiliary Circuit 1 N·m, Control Circuit 1 N·m, Main Circuit 1.2 N·m |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
Technical UL/CSA
| General Use Rating UL/CSA | (600 V AC) 30 A |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 2 hp, (200 ... 208 V AC) Three Phase 7.5 hp, (220 ... 240 V AC) Three Phase 7.5, (240 V AC) Single Phase 3 hp, (440 ... 480 V AC) Three Phase 15 hp, (550 ... 600 V AC) Three Phase 15 hp |
| Tightening Torque UL/CSA | Auxiliary Circuit 9 in·lb, Control Circuit 9 in·lb, Main Circuit 11 in·lb |
| Full Load Amps Motor Use | (120 V AC) Single Phase 24 A, (200 ... 208 V AC) Three Phase 25.3 A, (220 ... 240 V AC) Three Phase 22 A, (240 V AC) Single Phase 17 A, (440 ... 480 V AC) Three Phase 21 A, (550 ... 600 V AC) Three Phase 17 A |
Environmental
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C, Close to Contactor without Thermal O/L Relay -40 ... 70 °C, Close to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air -40 ... 70 °C |
| Climatic Withstand | according to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 Specification II |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
Material Compliance
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 467c94b0-9240-4a5e-b4c4-0716c2424515 Bulgaria |
| Simplified SCIP | 1cc00341-4654-40fe-b8a0-13249664ebbe Sweden, 26bf87c8-82f3-44af-a5b2-a503401710f8 Germany, 277166f0-bb6e-4a8d-b940-684ffdd0d8a6 Belgium, 29be2d44-ca37-478c-a441-df9beff5bf2b Hungary, 3d3c54d0-f2c9-41cf-b040-8e05167a2388 Germany, 502b1518-0d4b-4cd4-a7f5-00d993ca7809 Czechia, 56fb913e-c2a8-4388-9bef-6f528f5717b1 Spain, 57fa0089-1adc-4af7-a72f-578dc40af727 Netherlands, 6c23cab4-3d25-4f90-9145-ac547bbc21f6 Germany, 6d43edec-eaee-4cef-bdb5-01f06c096a2e Germany, 6eb9fb77-3b32-45a2-8a49-65e1138e449c Norway, 8096c567-054c-4aac-bfd6-5405a822837a Greece, 90217a03-8f05-4ef7-9d68-49336e538068 Poland, 97ac94a1-a6b9-4c82-b574-5babce3c2689 Poland, 992d4dcb-2748-4914-b36a-3a43f9d8d3ee Portugal, b6fa49fe-9c36-4512-8f90-aac5a905fa1d Germany, b8f196e1-3279-4660-84c5-69767d61835c Finland, bd47d4f4-4c5e-43cb-a9f4-709d63d21771 Belgium, c19b5e0e-aba4-43b5-81e5-1b16d023a68b France, c498f141-ea56-4ab2-a09f-356239e67bb5 Hungary, c7bdf7b2-9d2d-468b-8275-2e638659c467 France, c968d3d8-f617-44fd-ba58-34292bdc0ac9 Estonia, d66e76d4-5c52-41b7-a61e-d53b31eb20dc Croatia, e02c0e27-7cf7-4fae-9221-8deb1b60f286 Sweden, e667bf72-d035-41ed-91ce-bec8a0391feb Denmark, ee8e03ae-1195-4d10-9de3-4b0bf54a49a0 Poland, f4e3aaaf-cd32-4e57-96b0-bbcd4ec809f8 Italy |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
External Classifications and Standards
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4755 >> Contactors |
| E-Number (Finland) | 3707329 |
Downloads & documentation
Official documents from ABB, downloaded directly from the manufacturer.
Data sheets & manuals
| Data Sheet, Technical Information (1SBC100187L0203) | |
| Instructions and Manuals (9AKK107492A7057) |
CAD & dimension drawings
| CAD Dimensional Drawing (2CDC001079B0201) |
Certificates (8)
More ABB parts
Available on requestAX25-30-01-36 190V50Hz/220V60Hz Contactor
Available on requestAX25-30-10-36 190V50Hz/220V60Hz Contactor
Available on requestAX25-30-01-75 200V50HZ/200-220V60HZ Contactor
Available on requestAX25-30-10-75 200V50HZ/200-220V60HZ Contactor
Available on requestAX25-30-10-80 220-230V50Hz/230-240V60Hz Contactor
Available on requestAX25-30-01-81 24V 50/60Hz Contactor
Available on requestAX25-30-10-81 24V 50/60Hz Contactor
Available on requestAX25-30-01-83 48V 50/60Hz Contactor