Browse Subcategories
Available on requestSiemens 3RV2021-4AA20 – Circuit breaker size S0 for motor protectionMPN: 3RV2021-4AA20 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2411-1BA15 – Circuit breaker size S00 for transformer protection…MPN: 3RV2411-1BA15 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2411-1BA10 – Circuit breaker size S00 for transformer protection…MPN: 3RV2411-1BA10 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2411-1AA20-0DA0 – Circuit breaker size S00 for transformer protection without…MPN: 3RV2411-1AA20-0DA0 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2411-1AA20 – Circuit breaker size S00 for transformer protection…MPN: 3RV2411-1AA20 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2411-1AA15 – Circuit breaker size S00 for transformer protection…MPN: 3RV2411-1AA15 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2411-1AA10 – Circuit breaker size S00 for transformer protection…MPN: 3RV2411-1AA10 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2021-1BA10-Z W96 – Circuit breaker size S0 for motor protectionMPN: 3RV2021-1BA10-Z W96 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2021-1BA10 – Circuit breaker size S0 for motor protectionMPN: 3RV2021-1BA10 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2021-1AA25 – Circuit breaker size S0 for motor protectionMPN: 3RV2021-1AA25 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2021-1AA20-0BA0 – Special type Circuit breaker size S0 for motor protectionMPN: 3RV2021-1AA20-0BA0 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2021-1AA20-Z X95 – Circuit breaker size S0 for motor protectionMPN: 3RV2021-1AA20-Z X95 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2021-1AA20 – Circuit breaker size S0 for motor protectionMPN: 3RV2021-1AA20 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2021-1AA15 – Circuit breaker size S0 for motor protectionMPN: 3RV2021-1AA15 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2011-1DA20-Z W97 – Circuit breaker size S00 for motor protectionMPN: 3RV2011-1DA20-Z W97 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2011-1DA20-Z W96 – Circuit breaker size S00 for motor protectionMPN: 3RV2011-1DA20-Z W96 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2011-1DA20 – Circuit breaker size S00 for motor protectionMPN: 3RV2011-1DA20 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2011-1DA10-Z W97 – Circuit breaker size S00 for motor protectionMPN: 3RV2011-1DA10-Z W97 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2011-1DA10-Z W96 – Circuit breaker size S00 for motor protectionMPN: 3RV2011-1DA10-Z W96 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2011-1DA10 – Circuit breaker size S00 for motor protectionMPN: 3RV2011-1DA10 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2042-4JB10 – Circuit breaker size S3 for motor protectionMPN: 3RV2042-4JB10 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2042-4JA10 – Circuit breaker size S3 for motor protectionMPN: 3RV2042-4JA10 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2042-4HB10 – Circuit breaker size S3 for motor protectionMPN: 3RV2042-4HB10 · Siemens
Price on request
Request a quote
Available on requestSiemens 3RV2042-4HA10 – Circuit breaker size S3 for motor protectionMPN: 3RV2042-4HA10 · Siemens
Price on request
Request a quoteCompare SIRIUS 3RV2 motor starter protectors
Key specifications of the parts listed on this page, taken from the manufacturer's data sheets.
| MPN | continuous current rated value | Net Weight | adjustable current response value current of the current-dependent overload release | operational current rated value | operational current – at AC-3 at 400 V rated value |
|---|---|---|---|---|---|
| 3RV2411-1BA10 | 2 A | 323.6 g | 1.4 ... 2 A | 2 A | 2 A |
| 3RV2411-1AA10 | 1.6 A | 321.6 g | 1.1 ... 1.6 A | 1.6 A | 1.6 A |
| 3RV2021-1BA10-Z W96 | 2 A | 327.6 g | 1.4 ... 2 A | 2 A | 2 A |
| 3RV2021-1BA10 | 2 A | 327.6 g | 1.4 ... 2 A | 2 A | 2 A |
| 3RV2011-1DA10-Z W97 | 3.2 A | 324.6 g | 2.2 ... 3.2 A | 3.2 A | 3.2 A |
| 3RV2011-1DA10-Z W96 | 3.2 A | 324.6 g | 2.2 ... 3.2 A | 3.2 A | 3.2 A |
| 3RV2011-1DA10 | 3.2 A | 324.6 g | 2.2 ... 3.2 A | 3.2 A | 3.2 A |
Common to all listed parts
| Product equipment of circuit breaker for motor protection complete unit with protection device | Yes |
| size of contactor can be combined company-specific | S00, S0 |
| product function disconnector functionality | Yes |
| product extension auxiliary switch | Yes |
| power loss [W] for rated value of the current – at AC in hot operating state | 7.25 W |
| power loss [W] for rated value of the current – at AC in hot operating state per pole | 2.4 W |
| type of calculation of power loss current-dependent | quadratic |
| insulation voltage with degree of pollution 3 at AC rated value | 690 V |