Relay module; Nominal input voltage: 230 VAC; 1 changeover contact; Limiting continuous current: 6 A; with integrated base load module; Yellow status indicator; Module width: 6 mm; 2,50 mm²;
Relay module; Nominal input voltage: 230 VAC; 1 changeover contact; Limiting continuous current: 6 A; with gold contacts; with integrated base load module; Yellow status indicator; Module wid
Relay module; Nominal input voltage: 230 VAC; 1 changeover contact; Limiting continuous current: 6 A; with gold contacts; with integrated base load module; Yellow status indicator; Module width: 6 mm; 2,50 mm²; gray 857-368/006-000
| Safety Information | Adjacent devices of the same type are devices of the same design (series) that are arranged next to one another on the DIN-rail with the same orientation. An end stop (249-116) must be fitted to devices of other types for compliance with the reinforced insulation requirements. |
| Note | To prevent damaging the gold layer, 30 V switching voltages and 50 mA currents must not be exceeded. Higher switching power eventually evaporates the gold layer. The resulting deposits in the housing may reduce service life., To protect the relay coils and contacts, inductive loads must be dampened with an effective protection circuit. |
| Nominal input voltage U<sub>N</sub> | 230 VAC |
| Input voltage range | -15 … +10 % |
| Nominal input current at U<sub>N</sub> | 16 mA |
| Line capacitance (max.) | 170 nF |
| Cable length (control circuit) | ≤ 350 m (at a line capacitance of 330 nF/km) |
| Nominal frequency range (input voltage) | 50 … 60 HzAC |
| Number of changeover/switchover contacts | 1 |
| Contact material (relay) | AgNi + Au |
| Limiting continuous current | 6 A |
| Inrush current (resistive) max. | (AC) 20 A / 0.02 s |
| Switching Voltage, Max. | 250 VAC |
| Switching power (resistive) max. | AC 1500 VA; DC (see load limit curve) |
| Switching capacity | AC-15: 3 A / 250 VAC; DC-13: 2 A / 24 VDC |
| Recommended minimum load | 1 V / 1 mA / 1 mW |
| Pull-in time (typ.) | 15 ms |
| Drop-out time (typ.) | 25 ms |
| Bounce time (typ.) | 3.5 ms |
| Electrical life (NO; resistive load; 23 °C) | 50 x 10³ switching operations |
| Mechanical life | 5 x 10⁶ switching operations |
| Switching frequency with/without load (max.) | 6 min-1 / 180 min-1 |
| Status indicator | Yellow LED |
| Rated voltage | 300 V |
| Rated impulse withstand voltage | 4 kV |
| Type of circuits | Mains circuits |
| Overvoltage category | III |
| Pollution degree | 2 |
| Dielectric strength (control/load circuit) (AC, 1 min) | 3.51 kVrms |
| Dielectric strength (open contact) (AC, 1 min) | 1 kVrms |
| Insulation type (control/load circuit) | Reinforced insulation (safe isolation) |
| Insulation type (between adjacent devices of the same type) | Double insulation (safe isolation) |
| Insulation type (to adjacent devices of different types) | Basic insulation |
| Safety Information | Adjacent devices of the same type are devices of the same design (series) that are arranged next to one another on the DIN-rail with the same orientation. An end stop (249-116) must be fitted to devices of other types for compliance with the reinforced insulation requirements. |
| Protection type | IP20 |
| Connection technology | Push-in CAGE CLAMP® |
| Solid conductor | 0.34 … 2.5 mm² / 22 … 14 AWG |
| Fine-stranded conductor | 0.34 … 2.5 mm² / 22 … 14 AWG |
| Fine-stranded conductor; with insulated ferrule | 0.34 … 1.5 mm² / 22 … 16 AWG |
| Strip length | 9 … 10 mm / 0.35 … 0.39 inches |
| Width | 6 mm / 0.236 inches |
| Height | 94 mm / 3.701 inches |
| Depth from upper-edge of DIN-rail | 81 mm / 3.189 inches |
| Mounting type | DIN-35 rail |
| Mounting position | Horizontal (standing/lying); vertical |
| Note (material data) | Information on material specifications can be found here |
| Color | gray |
| Insulation material (main housing) | Polyamide (PA66) |
| Material group | I |
| Flammability class per UL94 | V0 |
| Fire load | 0.555 MJ |
| Weight | 31.5 g |
| Ambient temperature (operation at U<sub>N</sub>) | -40 … +60 °C |
| Ambient temperature (storage) | -40 … +70 °C |
| Processing temperature | -25 … +50 °C |
| Temperature range of connection cable | ≥ (Tambient + 30 K) |
| Relative humidity | 5 … 85 % (no condensation permissible) |
| Operating altitude (max.) | 2000 m |
| Standards/specifications | EN 61010-2-201, EN 61810-1, EN 61373 |
| WAGO Basic Relay | 857-157 |
| Product Group | 6 (INTERFACE ELECTRONIC) |
| PU (SPU) | 25 (1) pcs |
| Packaging type | box |
| Country of origin | DE |
| GTIN | 4050821873402 |
| Customs tariff number | 85364900990 |
| UNSPSC | 39122334 |
| eCl@ss 10.0 | 27-37-16-01 |
| eCl@ss 9.0 | 27-37-16-01 |
| ETIM 9.0 | EC001437 |
| ETIM 10.0 | EC001437 |
| ECCN | NO US CLASSIFICATION |
| CAS-No. | 1303-86-2, 7439-92-1, 79-94-7 |
| REACH Candidate List Substance | 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol, Diboron trioxide, Lead |
| RoHS Compliance Status | Compliant,With Exemption |
| RoHS Exemption | 7(a), 7(c)-I |
| SCIP notification number (Bulgaria) | c90e8389-8fc8-4d04-b6bf-ce110031b7e8 |
| SCIP notification number (Czech Republic) | 9842fd9b-292a-4d58-a8a9-6f6f56d1dc77 |
No matching specifications
857-368/006-000 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Yes — mention it when you request a quote for 857-368/006-000 and we'll include express shipping options in our reply.
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 857-368/006-000, subject to availability and destination.

Relay module; Nominal input voltage: 230 VAC; 1 changeover contact; Limiting continuous current: 6 A; with integrated base load module; Yellow status indicator; Module width: 6 mm; 2,50 mm²;

Relay module; Nominal input voltage: 24 … 230 V AC/DC; 1 changeover contact; Limiting continuous current: 6 A; Yellow status indicator; Module width: 6 mm

Relay module; Nominal input voltage: 24 V AC/DC; 1 changeover contact; Limiting continuous current: 6 A; with gold contacts; Yellow status indicator; Module width: 6 mm

Relay module; Nominal input voltage: 230 V AC/DC; 1 changeover contact; Limiting continuous current: 6 A; with gold contacts; Yellow status indicator; Module width: 6 mm; 2,50 mm²; gray

Relay module; Nominal input voltage: 24 … 230 V AC/DC; 1 changeover contact; Limiting continuous current: 6 A; with gold contacts; Yellow status indicator; Module width: 6 mm

Isolation amplifier; Current and voltage input signal; Current and voltage output signal; Zero/span adjustment; Configuration via DIP switch; Supply voltage: 24 VDC; 6 mm module width; 2,50 m

Isolation amplifier; Current and voltage input signal; Current and voltage output signal; Digital output; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²

Isolation amplifier; Current and voltage input signal; Bipolar current and voltage output signal; Configuration via DIP switch; Supply voltage: 24 VDC; 6 mm module width; 2,50 mm²