Relay module; Nominal input voltage: 230 VAC; 1 changeover contact; Limiting continuous current: 16 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

MPN
788-508
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Wago parts? We buy surplus →

What is the Wago 788-508?

Relay module; Nominal input voltage: 230 VAC; 1 changeover contact; Limiting continuous current: 16 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray 788-508

Specifications

Notes

Safety InformationA separator plate (e.g., 209-191) must be used for voltages exceeding 250 V between adjacent relay modules and to comply with reinforced insulation requirements.
NoteReinforced insulation between coil and contacts, To protect the relay coils and contacts, inductive loads must be dampened with an effective protection circuit.

Technical data - Control circuit

Nominal input voltage U<sub>N</sub>230 VAC
Input voltage range±10 %
Nominal input current at U<sub>N</sub>4 mA

Technical data - Load circuit

Number of changeover/switchover contacts1
Contact material (relay)AgNi 90/10
Limiting continuous current16 A
Inrush current (resistive) max.(AC) 30 A / 4 s
Switching Voltage, Max.250 VAC
Switching power (resistive) max.AC 4000 VA; DC (see load limit curve)
Switching capacityAC-15: 6 A / 250 VAC; DC-13: 2 A / 24 VDC
Recommended minimum load12 V / 10 mA
Pull-in time (typ.)10 ms
Drop-out time (typ.)35 ms
Bounce time (typ.)6 ms
Electrical life (NO; resistive load; 23 °C)30 x 10³ switching operations
Mechanical life5 x 10⁶ switching operations
Switching frequency with/without load (max.)6 min-1 / 600 min-1

Technical data - Signaling

Status indicatorRed LED

Safety and protection

Rated voltage250 V
Rated impulse withstand voltage4 kV
Pollution degree3
Dielectric strength (control/load circuit) (AC, 1 min)5 kVrms
Dielectric strength (open contact) (AC, 1 min)1 kVrms
Safety InformationA separator plate (e.g., 209-191) must be used for voltages exceeding 250 V between adjacent relay modules and to comply with reinforced insulation requirements.
Protection typeIP20

Connection data

Connection technologyPush-in CAGE CLAMP®
Solid conductor0.34 … 2.5 mm² / 22 … 14 AWG
Fine-stranded conductor0.34 … 2.5 mm² / 22 … 14 AWG
Strip length9 … 10 mm / 0.35 … 0.39 inches

Physical data

Width15 mm / 0.591 inches
Height86 mm / 3.386 inches
Depth from upper-edge of DIN-rail54 mm / 2.126 inches

Mechanical data

Mounting typeDIN-35 rail

Material data

Note (material data)Information on material specifications can be found here
Colorgray
Fire load0.843 MJ
Weight46 g

Environmental requirements

Ambient temperature (operation at U<sub>N</sub>)-40 … +70 °C
Ambient temperature UL (operation at U<sub>N</sub>)-40 … +40 °C
Ambient temperature (storage)-40 … +70 °C
Processing temperature-25 … +50 °C
Temperature range of connection cable≥ (Tambient + 20 K)

Standards and specifications

Standards/specificationsEN 61010-2-201, EN 61810-1, EN 61373, UL 508 (max. 40 °C), DNV

Basic relay

WAGO Basic Relay788-178

Commercial data

Product Group6 (INTERFACE ELECTRONIC)
PU (SPU)20 (1) pcs
Packaging typebox
Country of originCN
GTIN4055143192347
Customs tariff number85364900990

Product Classification

UNSPSC39122334
eCl@ss 10.027-37-16-01
eCl@ss 9.027-37-16-01
ETIM 9.0EC001437
ETIM 10.0EC001437
ECCNNO US CLASSIFICATION

Environmental Product Compliance

CAS-No.7439-92-1, 79-94-7
REACH Candidate List Substance2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol, Lead
RoHS Compliance StatusCompliant,With Exemption
RoHS Exemption7(a)
SCIP notification number (Austria)1ff4f8fd-84d5-44d8-8eed-34cca1e26a49
SCIP notification number (Belgium)c193c014-da37-41d6-8c7e-f08334dafe84
SCIP notification number (Bulgaria)e04c232c-7216-4c6a-9dd8-11f3575588ee
SCIP notification number (Czech Republic)0a4c5114-38af-491c-9b67-06be20f57747
SCIP notification number (Denmark)f8646027-ced0-49e7-8f2f-9d917264cbb6
SCIP notification number (Finland)19d83842-fef3-4481-aac5-5450a6ca83ed
SCIP notification number (France)c62f1a8e-c6c9-436e-8b6c-19919b833cc9
SCIP notification number (Germany)863e063b-247f-41c0-9d76-fdbccac297bd
SCIP notification number (Hungary)2da77dbb-2c11-4158-8fb9-4f668ae81af4
SCIP notification number (Italy)ca06c26d-b965-4ef5-88db-fe2b0dd29334
SCIP notification number (Netherlands)162cfe5b-b770-480c-9994-327f7741468a
SCIP notification number (Poland)78bbbc07-5984-440d-9360-29004fccb15b
SCIP notification number (Romania)db2f516b-0cb7-4862-a0dc-d05708b95da4
SCIP notification number (Sweden)0d6c29c4-589d-4cc4-b325-89aaa52177c6

788-508: frequently asked questions

When can 788-508 be shipped?

788-508 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 788-508 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 788-508 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 788-508, subject to availability and destination.

More Wago parts

Wago 788-404 – Relay module; Nominal input voltage: 24 VDC; 1 changeover contact; Limiting continuous current: 16 A; with gold contacts; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-404

Relay module; Nominal input voltage: 24 VDC; 1 changeover contact; Limiting continuous current: 16 A; with gold contacts; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-412 – Relay module; Nominal input voltage: 24 VDC; 2 changeover contacts; Limiting continuous current: 8 A; with gold contacts; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-412

Relay module; Nominal input voltage: 24 VDC; 2 changeover contacts; Limiting continuous current: 8 A; with gold contacts; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-506 – Relay module; Nominal input voltage: 24 VAC; 1 changeover contact; Limiting continuous current: 16 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-506

Relay module; Nominal input voltage: 24 VAC; 1 changeover contact; Limiting continuous current: 16 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-507 – Relay module; Nominal input voltage: 115 VAC; 1 changeover contact; Limiting continuous current: 16 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-507

Relay module; Nominal input voltage: 115 VAC; 1 changeover contact; Limiting continuous current: 16 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-512 – Relay module; Nominal input voltage: 24 VAC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-512

Relay module; Nominal input voltage: 24 VAC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-515 – Relay module; Nominal input voltage: 115 VAC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-515

Relay module; Nominal input voltage: 115 VAC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-516 – Relay module; Nominal input voltage: 230 VAC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-516

Relay module; Nominal input voltage: 230 VAC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-541 – Relay module; Nominal input voltage: 24 VAC; 1 changeover contact; Limiting continuous current: 16 A; with manual operation; Red status indicator; Module width: 15 mm
Wago
788-541

Relay module; Nominal input voltage: 24 VAC; 1 changeover contact; Limiting continuous current: 16 A; with manual operation; Red status indicator; Module width: 15 mm

Wago 788-508Price and lead time confirmed within 1 business day
Request a Quote