Wago 788-506

Relay module; Nominal input voltage: 24 VAC; 1 changeover contact; Limiting continuous current: 16 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

MPN
788-506
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Wago parts? We buy surplus →

What is the Wago 788-506?

Relay module; Nominal input voltage: 24 VAC; 1 changeover contact; Limiting continuous current: 16 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray 788-506

Specifications

Notes

Safety InformationA separator plate (e.g., 209-191) must be used for voltages exceeding 250 V between adjacent relay modules and to comply with reinforced insulation requirements.
NoteReinforced insulation between coil and contacts, To protect the relay coils and contacts, inductive loads must be dampened with an effective protection circuit.

Technical data - Control circuit

Nominal input voltage U<sub>N</sub>24 VAC
Input voltage range±10 %
Nominal input current at U<sub>N</sub>34 mA

Technical data - Load circuit

Number of changeover/switchover contacts1
Contact material (relay)AgNi 90/10
Limiting continuous current16 A
Inrush current (resistive) max.(AC) 30 A / 4 s
Switching Voltage, Max.250 VAC
Switching power (resistive) max.AC 4000 VA; DC (see load limit curve)
Switching capacityAC-15: 6 A / 250 VAC; DC-13: 2 A / 24 VDC
Recommended minimum load12 V / 10 mA
Pull-in time (typ.)10 ms
Drop-out time (typ.)35 ms
Bounce time (typ.)6 ms
Electrical life (NO; resistive load; 23 °C)30 x 10³ switching operations
Mechanical life5 x 10⁶ switching operations
Switching frequency with/without load (max.)6 min-1 / 600 min-1

Technical data - Signaling

Status indicatorRed LED

Safety and protection

Rated voltage250 V
Rated impulse withstand voltage4 kV
Pollution degree3
Dielectric strength (control/load circuit) (AC, 1 min)5 kVrms
Dielectric strength (open contact) (AC, 1 min)1 kVrms
Safety InformationA separator plate (e.g., 209-191) must be used for voltages exceeding 250 V between adjacent relay modules and to comply with reinforced insulation requirements.
Protection typeIP20

Connection data

Connection technologyPush-in CAGE CLAMP®
Solid conductor0.34 … 2.5 mm² / 22 … 14 AWG
Fine-stranded conductor0.34 … 2.5 mm² / 22 … 14 AWG
Strip length9 … 10 mm / 0.35 … 0.39 inches

Physical data

Width15 mm / 0.591 inches
Height86 mm / 3.386 inches
Depth from upper-edge of DIN-rail54 mm / 2.126 inches

Mechanical data

Mounting typeDIN-35 rail

Material data

Note (material data)Information on material specifications can be found here
Colorgray
Fire load0.666 MJ
Weight46.4 g

Environmental requirements

Ambient temperature (operation at U<sub>N</sub>)-40 … +70 °C
Ambient temperature UL (operation at U<sub>N</sub>)-40 … +50 °C
Ambient temperature (storage)-40 … +70 °C
Processing temperature-25 … +50 °C
Temperature range of connection cable≥ (Tambient + 20 K)

Standards and specifications

Standards/specificationsEN 61010-2-201, EN 61810-1, EN 61373, UL 508, DNV

Basic relay

WAGO Basic Relay788-170

Commercial data

Product Group6 (INTERFACE ELECTRONIC)
PU (SPU)20 (1) pcs
Packaging typebox
Country of originDE
GTIN4045454424121
Customs tariff number85364900990

Product Classification

UNSPSC39122334
eCl@ss 10.027-37-16-01
eCl@ss 9.027-37-16-01
ETIM 9.0EC001437
ETIM 10.0EC001437
ECCNNO US CLASSIFICATION

Environmental Product Compliance

RoHS Compliance StatusCompliant,No Exemption
SCIP notification number (Austria)909324ad-5e3b-4d39-ad4f-2fbc4d58bde5
SCIP notification number (Belgium)2c9fa0df-83b1-4815-91a2-7420bb644f3d
SCIP notification number (Bulgaria)d4bc7641-1e5c-454e-977e-43e41bda5d2b
SCIP notification number (Czech Republic)185a21da-bc74-4fab-9583-08d99a980130
SCIP notification number (Denmark)5d95b346-802a-4648-9638-9a67776bd077
SCIP notification number (Finland)6307942c-93c4-4d51-9c5d-112763aa753c
SCIP notification number (France)101db39d-73f5-4185-bf71-1dfa3c602d18
SCIP notification number (Germany)0c83fb69-743e-42a6-a8b0-58d28f4344c9
SCIP notification number (Hungary)330a7887-84f7-4a37-aeca-9a0d031f6c07
SCIP notification number (Italy)d5373a56-298a-4009-a1f0-ab3127f4bdb0
SCIP notification number (Netherlands)45ab6da9-0832-49bd-9e11-62137072e4c0
SCIP notification number (Poland)e660e88e-4666-4e59-a612-4a6409aa3aca
SCIP notification number (Romania)1249d728-d991-4cbb-90d2-afb832e9a5cd
SCIP notification number (Sweden)4cc42db8-2306-423c-8bfe-e1ab465fd20a

788-506: frequently asked questions

When can 788-506 be shipped?

788-506 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 788-506 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 788-506 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 788-506, subject to availability and destination.

More Wago parts

Wago 788-390 – Relay module; Nominal input voltage: 24 VDC; 2 changeover contacts; Limiting continuous current: 8 A; Railway; Red status indicator; Module width: 15 mm
Wago
788-390

Relay module; Nominal input voltage: 24 VDC; 2 changeover contacts; Limiting continuous current: 8 A; Railway; Red status indicator; Module width: 15 mm

Wago 788-391 – Relay module; Nominal input voltage: 24 VDC; 1 changeover contact; Limiting continuous current: 16 A; with manual operation; Railway; Red status indicator; Module width: 15 mm
Wago
788-391

Relay module; Nominal input voltage: 24 VDC; 1 changeover contact; Limiting continuous current: 16 A; with manual operation; Railway; Red status indicator; Module width: 15 mm

Wago 788-404 – Relay module; Nominal input voltage: 24 VDC; 1 changeover contact; Limiting continuous current: 16 A; with gold contacts; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-404

Relay module; Nominal input voltage: 24 VDC; 1 changeover contact; Limiting continuous current: 16 A; with gold contacts; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-412 – Relay module; Nominal input voltage: 24 VDC; 2 changeover contacts; Limiting continuous current: 8 A; with gold contacts; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-412

Relay module; Nominal input voltage: 24 VDC; 2 changeover contacts; Limiting continuous current: 8 A; with gold contacts; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-507 – Relay module; Nominal input voltage: 115 VAC; 1 changeover contact; Limiting continuous current: 16 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-507

Relay module; Nominal input voltage: 115 VAC; 1 changeover contact; Limiting continuous current: 16 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-508 – Relay module; Nominal input voltage: 230 VAC; 1 changeover contact; Limiting continuous current: 16 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-508

Relay module; Nominal input voltage: 230 VAC; 1 changeover contact; Limiting continuous current: 16 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-512 – Relay module; Nominal input voltage: 24 VAC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-512

Relay module; Nominal input voltage: 24 VAC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-515 – Relay module; Nominal input voltage: 115 VAC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray
Wago
788-515

Relay module; Nominal input voltage: 115 VAC; 2 changeover contacts; Limiting continuous current: 8 A; Red status indicator; Module width: 15 mm; 2,50 mm²; gray

Wago 788-506Price and lead time confirmed within 1 business day
Request a Quote