Fieldbus Coupler Modbus TCP M12; 4th generation; Extreme
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | I/O Systems |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can 750-364/040-010 be shipped?
750-364/040-010 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 750-364/040-010 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 750-364/040-010 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 750-364/040-010, subject to availability and destination.
The Modbus TCP/UDP Fieldbus Coupler connects ETHERNET to the modular WAGO I/O System.<br/>The fieldbus coupler detects all connected I/O modules and creates a local process image. <br/>Two ETHERNET interfaces and an integrated switch allow the fieldbus to be wired in a line topology, eliminating the need for additional network devices, such as switches or hubs.<br/>Both interfaces support autonegotiation and Auto-MDI(X).<br/>The rotary switch configures the last byte of the IP address and may be used for IP address assignment (DHCP, BootP).<br/><br/>The coupler is designed for fieldbus communication in MODBUS® networks. It also supports a wide variety of standard ETHERNET protocols (e.g., HTTP(S), BootP, DHCP, DNS, SNMP, (S)FTP). An integrated Webserver provides user configuration options, while displaying the coupler's status information. <br/><br/>The device is ideal for operation in extreme environments thanks to:<br/><ul><li>An extended temperature range</li><li>Greater immunity to impulse voltages and electromagnetic interference</li><li>Higher vibration and shock resistance</li></ul>
Specifications
Technical data
| Communications | Modbus (TCP, UDP) |
| ETHERNET protocols | HTTP(S), BootP, DHCP, DNS, FTP(S), SNMP |
| Transmission rate | 10/100 Mbit/s |
| Transmission medium (communication/fieldbus) | Twisted pair S-UTP; 100 Ω; Cat. 5; M12 D-coded; 100 m maximum cable length |
| Transmission performance | Class D per EN 50173 |
| Number of modules per node (max.) | 64 |
| Number of modules without a bus extension (max.) | 64 |
| Configuration options | WAGO-I/O-CHECK, Web-Based Management, CODESYS Library |
| Input and output process image (fieldbus) max. | 1020 words/1020 words |
| Supply voltage (system) | 24 VDC; via pluggable connector (CAGE CLAMP® connection); Derating must be observed! |
| Current consumption (5 V system supply) | 350 mA |
| Total current (system supply) | 1,700 mA |
| Supply voltage (field) | 24 VDC; Power supply via pluggable connector (CAGE CLAMP® connection); Transmission via power jumper contacts; Derating must be observed! |
| Input current (typ.) at nominal load (24 V) | 500 mA |
| Power supply efficiency (typ.) at nominal load (24 V) | 90 % |
| Current carrying capacity (power jumper contacts) | 10 A |
| Rated impulse withstand voltage | 1 kV |
| Derating | Derating (supply voltage):Ambient temperatures under laboratory conditions: (-25 … +30 %);for -40 … +55 °C: 24 V (-25 … +20 %);for +55 … +70 °C: 24 V (-25 … +10 %);Lower limit in all temperature ranges: -27.5 % (including 15 % residual ripple) |
| Indicators | LED (LINK/ACT) green: Network connection via ports 1 … 2; LED (MS, NS) red/green: Status of node, network; LED (I/O) red/green/orange: Status of local data bus |
Connection data
| Connection technology: communication/fieldbus | Modbus (TCP, UDP): 2 x M12 socket; 4-pole; D-coded |
| Connection technology: field supply | 6 x CAGE CLAMP® |
| Connection technology: system supply | 2 x CAGE CLAMP® |
| Connectable conductor materials | Copper |
| Connection type | System/field supply |
| Solid conductor | 0.25 … 2.5 mm² / 24 … 14 AWG |
| Fine-stranded conductor | 0.25 … 2.5 mm² / 24 … 14 AWG |
| Strip length | 8 … 9 mm / 0.31 … 0.35 inches |
| Connection technology: device configuration | 1 x Male connector; 4-pole |
Physical data
| Width | 112 mm / 4.409 inches |
| Height | 100 mm / 3.937 inches |
| Depth | 71.9 mm / 2.831 inches |
| Depth from upper-edge of DIN-rail | 64.7 mm / 2.547 inches |
Mechanical data
| Mounting type | DIN-35 rail |
Material data
| Housing material | Polycarbonate; polyamide 6.6 |
| Fire load | 3.269 MJ |
| Weight | 213 g |
| Conformity marking | CE |
Environmental requirements
| Ambient temperature (operation) | -40 … +70 °C |
| Ambient temperature (storage) | -40 … +85 °C |
| Ambient temperature (installation) | -20 … +70 °C |
| Protection type | IP20 |
| Pollution degree | 2 per IEC 61131-2 |
| Operating altitude | without temperature derating: 0 … 2000 m; with temperature derating: 2000 … 5000 m (0.5 K/100 m); 5000 m (max.) |
| Mounting position | Horizontal left, horizontal up, vertical top and vertical bottom |
| Relative humidity (without condensation) | 95 % |
| Relative humidity (with condensation) | Short-term condensation per Class 3K7/IEC EN 60721-3-3 and E-DIN 40046-721-3 (except for wind-driven precipitation, water and ice formation) |
| Vibration resistance | According to type test for marine classification (ABS, BV, DNV, IACS, LR): acceleration: 5g, IEC 60068-2-6, EN 60870-2-2, IEC 60721-3-1, -3, EN 50155, EN 61373 |
| Shock resistance | per IEC 60068-2-27 (10g/16 ms/half-sine/1,000 shocks; 25g/6 ms/half-sine/1,000 shocks), EN 50155, EN 61373 |
| EMC immunity to interference | per EN 61000-6-1, -2; EN 61131-2; marine applications; EN 50121-3-2; EN 50121-4, -5; EN 60255-26; EN 60870-2-1; EN 61850-3; IEC 61000-6-5; IEEE 1613; VDEW: 1994 |
| EMC emission of interference | per EN 61000-6-3, -4, EN 61131-2, EN 60255-26, marine applications, EN 60870-2-1, EN 61850-3, EN 50121-3-2, EN 50121-4, -5 |
| Exposure to pollutants | per IEC 60068-2-42 and IEC 60068-2-43 |
| Permissible H<sub>2</sub>S contaminant concentration at a relative humidity <lt/> 75 % | 10 ppm |
| Permissible SO<sub>2</sub> contaminant concentration at a relative humidity <lt/> 75 % | 25 ppm |
Commercial data
| PU (SPU) | 1 pcs |
| Packaging type | Box |
| Country of origin | DE |
| GTIN | 4055143923026 |
| Customs tariff number | 85371091990 |
Product Classification
| UNSPSC | 32151705 |
| ETIM 9.0 | EC001603 |
| ETIM 10.0 | EC001603 |
| ECCN | NO US CLASSIFICATION |
Environmental Product Compliance
| CAS-No. | 1303-86-2, 1317-36-8, 7439-92-1, 79-94-7 |
| REACH Candidate List Substance | 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol, Diboron trioxide, Lead, Lead monoxide, Perfluorobutane sulfonic acid (PFBS) and its salts |
| RoHS Compliance Status | Compliant,With Exemption |
| RoHS Exemption | 6(c), 7(a), 7(c)-I, 7(c)-II |
| SCIP notification number (Austria) | fd0b3d11-fef3-4362-b097-eb649e745b1d |
| SCIP notification number (Belgium) | ff12d840-2ee4-4f59-9444-2631e34e3723 |
| SCIP notification number (Bulgaria) | 50393ef7-c9a5-4525-9c03-841a44052264 |
| SCIP notification number (Czech Republic) | 3ab4865f-3708-4f1a-988f-4f2f73e5adfa |
| SCIP notification number (Denmark) | e1cde183-f47f-43dd-93fe-987c1ecce384 |
| SCIP notification number (Finland) | cfb5241d-bbc8-4948-8620-c03f83c40a9c |
| SCIP notification number (France) | 091653e8-a507-4c5b-beea-60551d1e2bd7 |
| SCIP notification number (Germany) | 5fbc9028-1c1f-44ea-a381-761c3e77ed4e |
| SCIP notification number (Hungary) | 947796b1-364f-4ef0-af07-cdc7a5fb1903 |
| SCIP notification number (Italy) | d5ea85cf-0ac9-49cc-9331-671a1c16a0b8 |
| SCIP notification number (Netherlands) | b0eba6a8-c4e3-445a-8963-a812287e92fc |
| SCIP notification number (Poland) | 749e9508-e18f-42b9-9fb2-7041dc4bb49f |
| SCIP notification number (Romania) | 6fadd179-0157-44cb-a900-18fb024a0fda |
| SCIP notification number (Sweden) | 2f11d552-1bff-459e-bba7-bcd84e975d3d |