Siemens 6ES7677-2DD42-0GB0
SIMATIC ET 200SP Open Controller, CPU 1515SP PC3 consisting of: basic unit (6ES7677-2DD42-0AA0) 8 GB RAM
- MPN
- 6ES7677-2DD42-0GB0
- Category
- CPU & Controllers
Request a Quote
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- Ships via
- 100% positive eBay feedback
What is the Siemens 6ES7677-2DD42-0GB0?
SIMATIC ET 200SP Open Controller, CPU 1515SP PC3 consisting of: basic unit (6ES7677-2DD42-0AA0) 8 GB RAM, 1x slot SSD, 3x USB 3.2; 1x DisplayPort; 1 x connection for ET 200SP bus adapter PROFINET IRT, 1 x Ethernet/PROFINET RT can be switched over for OS/CPU, 1 x Ethernet, max. 2500 Mbps, including server module (6ES7193-6PA00-0AA0); SSD (6ES7678-2BA00-0AA0) preinstalled: Windows 10 IoT Enterprise LTSC 2021 64-bit and S7-1500 Software Controller CPU 1505SP V4x; license package: OS and CPU
Specifications
General information
| Product type designation | CPU 1515SP PC3 |
| Firmware version | V40.0 |
| I&M data | Yes; I&M0 to I&M3 |
| Isochronous mode | Yes; only with PROFINET; with minimum OB 6x cycle of 500 µs |
| SysLog | Yes |
| STEP 7 TIA Portal configurable/integrated from version | V20 or higher |
| Visualization | No |
| Control | S7-1500 Software Controller CPU 1505SP |
Configuration control
| via dataset | Yes |
Control elements
| Mode selector switch | 1 |
Supply voltage
| Rated value (DC) | 24 V |
| permissible range, lower limit (DC) | 19.2 V |
| permissible range, upper limit (DC) | 28.8 V |
| Reverse polarity protection | Yes |
Input current
| Current consumption (rated value) | 0.9 A; Full processor load, incl. ET 200SP modules and using USB |
| Current consumption (in no-load operation), typ. | 0.6 A |
| Current consumption, max. | 2.4 A |
| I²t | 0.3 A²·s; with starting current inrush |
Power
| Active power input, max. | 43 W; incl. ET 200SP modules and using USB |
| Infeed power to the backplane bus | 8.75 W |
Power loss
| Power loss, typ. | 15 W |
Processor
| Processor type | Intel Atom x6416RE, 1,7 Ghz, 4 Cores |
Storage
| Type of memory | DDR4L |
| Main memory | 8 GB RAM |
| CFast memory card | No |
| SIMATIC memory card required | No; Use of the PC mass storage |
| integrated (for program) | 3 Mbyte |
| integrated (for data) | 10 Mbyte |
| integrated (for CPU function library of CPU Runtime) | 20 Mbyte |
| integrated (on PC mass storage) | 320 Mbyte |
| with UPS | Yes; all memory areas declared retentive |
| with non-volatile memory | Yes |
CPU-blocks
| Number of elements (total) | 8 000; In addition to blocks such as DBs, FBs and FCs, UDTs, global constants, etc. are also regarded as elements |
| Number, max. | 7 999; Number range: 1 to 65535 |
| Size, max. | 10 Mbyte; For DBs with absolute addressing, the max. size is 64 KB |
| Number, max. | 7 998; Number range: 1 to 65535 |
| Size, max. | 1 024 kbyte |
| Number, max. | 7 999; Number range: 1 to 65535 |
| Size, max. | 1 024 kbyte |
| Size, max. | 1 024 kbyte |
| Number of free cycle OBs | 100 |
| Number of time alarm OBs | 20 |
| Number of delay alarm OBs | 20 |
| Number of cyclic interrupt OBs | 20 |
| Number of process alarm OBs | 50 |
| Number of DPV1 alarm OBs | 3 |
| Number of isochronous mode OBs | 1 |
| Number of technology synchronous alarm OBs | 2 |
| Number of startup OBs | 100 |
| Number of asynchronous error OBs | 4 |
| Number of synchronous error OBs | 2 |
| Number of diagnostic alarm OBs | 1 |
| per priority class | 24 |
Counters, timers and their retentivity
| Number | 2 048 |
| — adjustable | Yes |
| Number | Any (only limited by the main memory) |
| — adjustable | Yes |
| Number | 2 048 |
| — adjustable | Yes |
| Number | Any (only limited by the main memory) |
| — adjustable | Yes |
Data areas and their retentivity
| Retentive data area (incl. timers, counters, flags), max. | 410 kbyte |
| Extended retentive data area (incl. timers, counters, flags), max. | 5 Mbyte; When using PC mass storage for retentive data |
| Size, max. | 16 kbyte |
| Number of clock memories | 8; 8 clock memory bit, grouped into one clock memory byte |
| Retentivity adjustable | Yes |
| Retentivity preset | No |
| per priority class, max. | 64 kbyte; max. 16 KB per block |
Address area
| Number of IO modules | 8 192; max. number of modules / submodules |
| Inputs | 32 kbyte; All inputs are in the process image |
| Outputs | 32 kbyte; All outputs are in the process image |
| Number of subprocess images, max. | 32 |
Hardware configuration
| Number of distributed IO systems | 20 |
| via PC interfaces | 2 |
| Modules per rack, max. | 64; CPU 1515SP PC + 64 modules + server module |
| Quantity of operable ET 200SP modules, max. | 64 |
| Quantity of operable ET 200AL modules, max. | 16 |
| Number of lines, max. | 1 |
| Number of PtP CMs | the number of connectable PtP CMs is only limited by the number of available slots |
Time of day
| Type | Hardware clock |
| Hardware clock (real-time) | Yes; Resolution: 1 s |
| Backup time | 6 wk; At 40 °C ambient temperature, typically |
| Deviation per day, max. | 10 s; Typ.: 2 s |
| supported | Yes |
| on Ethernet via NTP | Yes |
| on Windows clock, device | Yes |
Interfaces
| Number of industrial Ethernet interfaces | 3 |
| Number of PROFINET interfaces | 2 |
| Number of PROFIBUS interfaces | 0 |
| Number of RS 485 interfaces | 0 |
| Number of USB interfaces | 3; 3x USB 3.1 Gen1 type A |
| Graphics interface | 1x DisplayPort |
1. Interface
| Interface type | PROFINET |
| automatic detection of transmission rate | Yes |
| Autonegotiation | Yes |
| Autocrossing | Yes |
| Number of connections | 88 |
| RJ 45 (Ethernet) | Yes; X1 P1 and X1 P2 via BusAdapter BA 2x RJ45 |
| — Transmission rate, max. | 100 Mbit/s |
| Number of ports | 2; via BusAdapter |
| integrated switch | Yes |
| BusAdapter (PROFINET) | Yes; compatible BusAdapters: BA 2x RJ45, BA 2x M12, BA 2x FC |
| IP protocol | Yes; IPv4 |
| PROFINET IO Controller | Yes |
| PROFINET IO Device | Yes |
| SIMATIC communication | Yes |
| Open IE communication | Yes; Optionally also encrypted |
| Web server | Yes |
| Media redundancy | Yes |
| — Isochronous mode | Yes |
| — Direct data exchange | Yes; Requirement: IRT and isochronous mode (MRPD optional) |
| — shortest clock pulse | 500 µs |
| — IRT | Yes |
| — PROFIenergy | Yes; per user program |
| — Prioritized startup | Yes; Max. 32 PROFINET devices |
| — Number of connectable IO Devices, max. | 128 |
| — Of which IO devices with IRT, max. | 64 |
| — of which in line, max. | 64 |
| — Number of connectable IO Devices for RT, max. | 128 |
| — of which in line, max. | 128 |
| — Number of IO Devices that can be simultaneously activated/deactivated, max. | 8; in total across all interfaces |
| — IO Devices changing during operation (partner ports), supported | Yes |
| — Number of IO Devices per tool, max. | 8 |
| — Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data |
| — PROFINET Security Class | 1 |
| — for send cycle of 500 µs | 500 µs to 8 ms |
| — for send cycle of 1 ms | 1 ms to 16 ms |
| — for send cycle of 2 ms | 2 ms to 32 ms |
| — for send cycle of 4 ms | 4 ms to 64 ms |
| — With IRT and parameterization of "odd" send cycles | Update time = set "odd" send clock (any multiple of 125 µs: 625 µs ... 3 875 µs) minimum cycle time start from 500 µs |
| — for send cycle of 500 µs | 500 µs to 256 ms |
| — for send cycle of 1 ms | 1 ms to 512 ms |
| — for send cycle of 2 ms | 2 ms to 512 ms |
| — for send cycle of 4 ms | 4 ms to 512 ms |
| — Inputs, max. | 8 kbyte |
| — Outputs, max. | 8 kbyte |
| — Isochronous mode | No |
| — IRT | Yes |
| — PROFIenergy | Yes; per user program |
| — Shared device | Yes |
| — Number of IO Controllers with shared device, max. | 4 |
| — activation/deactivation of I-devices | Yes; per user program |
| — Asset management record | Yes; per user program |
| — PROFINET Security Class | SNMP Configuration and DCP Read Only |
2. Interface
| Interface type | Onboard PROFINET / IE interface X10 |
| automatic detection of transmission rate | Yes |
| Autonegotiation | Yes |
| Autocrossing | Yes |
| RJ 45 (Ethernet) | Yes; Integrated |
| — Transmission rate, max. | 1 000 Mbit/s; 100 Mbit/s, if PROFINET IO-Controller configured |
| Number of ports | 1 |
| IP protocol | Yes; IPv4 |
| PROFINET IO Controller | Yes |
| PROFINET IO Device | Yes |
| SIMATIC communication | Yes |
| Open IE communication | Yes; Optionally also encrypted |
| Web server | Yes |
| Media redundancy | No |
| — Isochronous mode | No |
| — Direct data exchange | No |
| — IRT | No |
| — PROFIenergy | Yes; per user program |
| — Prioritized startup | No |
| — Number of connectable IO Devices, max. | 32 |
| — Number of connectable IO Devices for RT, max. | 32 |
| — of which in line, max. | 32 |
| — Number of IO Devices that can be simultaneously activated/deactivated, max. | 8; in total across all interfaces |
| — Number of IO Devices per tool, max. | 8 |
| — Updating times | The minimum value of the update time also depends on communication share set for PROFINET IO, on the number of IO devices, and on the quantity of configured user data |
| — PROFINET Security Class | 1 |
| — for send cycle of 1 ms | 1 ms to 512 ms |
| — Isochronous mode | No |
| — IRT | No |
| — PROFIenergy | Yes; per user program |
| — Prioritized startup | No |
| — Shared device | Yes |
| — Number of IO Controllers with shared device, max. | 4 |
| — activation/deactivation of I-devices | Yes; per user program |
| — Asset management record | Yes; per user program |
| — PROFINET Security Class | SNMP Configuration and DCP Read Only |
3. Interface
| Interface type | Integrated Ethernet interface |
| RJ 45 (Ethernet) | Yes; X20 |
| — Transmission rate, max. | 1 000 Mbit/s |
| Number of ports | 1 |
Protocols
| PROFIsafe | No |
| Number of connections, max. | 88 |
| Number of connections reserved for ES/HMI/web | 10 |
| Number of S7 routing paths | 16 |
| H-Sync forwarding | Yes |
| — Media redundancy | Yes; only via BusAdapter |
| — MRP | Yes; MRP Automanager according to IEC 62439-2 Edition 2.0, MRP Manager; MRP Client |
| — MRP interconnection, supported | Yes; as MRP ring node according to IEC 62439-2 Edition 3.0 |
| — MRPD | Yes; Requirement: IRT |
| — Switchover time on line break, typ. | 200 ms; For MRP, bumpless for MRPD |
| — Number of stations in the ring, max. | 50 |
| PG/OP communication | Yes; encryption with TLS V1.3 pre-selected |
| S7 routing | Yes |
| S7 communication, as server | Yes |
| S7 communication, as client | Yes |
| User data per job, max. | See online help (S7 communication, user data size) |
| TCP/IP | Yes |
| — Data length, max. | 64 kbyte |
| — several passive connections per port, supported | Yes |
| ISO-on-TCP (RFC1006) | Yes |
| — Data length, max. | 64 kbyte |
| UDP | Yes |
| — Data length, max. | 2 kbyte; 1 472 bytes for UDP broadcast |
| — UDP multicast | Yes; max. 78 multicast circuits |
| DHCP | Yes |
| DNS | Yes |
| SNMP | Yes |
| DCP | Yes |
| LLDP | Yes |
| Encryption | Yes; Optional |
| HTTP | Yes; Standard and user pages |
| HTTPS | Yes; Standard and user pages |
| web API | Yes |
| — Number of sessions, max. | 100 |
| — number of simultaneous HTTP calls, max. | 4 |
| — HTTP request body, max. | 131 072 byte |
| Runtime license required | Yes; "Medium" license required |
| OPC UA Client | Yes; Data Access (registered Read/Write), Method Call |
| — Application authentication | Yes |
| — Security policies | Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 |
| — User authentication | "anonymous" or by user name & password |
| — Number of connections, max. | 10 |
| — Number of nodes of the client interfaces, recommended max. | 2 000 |
| — Number of elements for one call of OPC_UA_NodeGetHandleList/OPC_UA_ReadList/OPC_UA_WriteList, max. | 300 |
| — Number of elements for one call of OPC_UA_NameSpaceGetIndexList, max. | 20 |
| — Number of elements for one call of OPC_UA_MethodGetHandleList, max. | 100 |
| — Number of simultaneous calls of the client instructions for session management, per connection, max. | 1 |
| — Number of simultaneous calls of the client instructions for data access, per connection, max. | 5 |
| — Number of registerable nodes, max. | 5 000 |
| — Number of registerable method calls of OPC_UA_MethodCall, max. | 100 |
| — Number of inputs/outputs when calling OPC_UA_MethodCall, max. | 20 |
| OPC UA Server | Yes; data access (read, write, subscribe), method call, alarms & condition (A&C), custom address space, role-based access control |
| — Application authentication | Yes |
| — Security policies | available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256, Aes128Sha256RsaOaep, Aes256Sha256RsaPss |
| — User authentication | "anonymous" or by user name & password |
| — GDS support (certificate management) | Yes |
| — Number of sessions, max. | 48 |
| — Number of accessible variables, max. | 100 000 |
| — Number of registerable nodes, max. | 20 000 |
| — Number of subscriptions per session, max. | 50 |
| — Sampling interval, min. | 100 ms |
| — Publishing interval, min. | 100 ms |
| — Number of server methods, max. | 50; max. 20 concurrently running jobs each for asynchronous instructions OPC_UA_ServerMethodPre and OPC_UA_ServerMethodPost |
| — Number of inputs/outputs per server method, max. | 20 |
| — Number of monitored items, recommended max. | 4 000; for 1 s sampling interval and 1 s send interval |
| — Number of server interfaces, max. | 10 of each "Server interfaces" / "Companion specification" type and 20 of the type "Reference namespace" |
| — Number of nodes for user-defined server interfaces, max. | 30 000 |
| Alarms and Conditions | Yes |
| — Number of program alarms | 200 |
| — Number of alarms for system diagnostics | 100 |
| MODBUS | Yes; MODBUS TCP |
S7 message functions
| Number of login stations for message functions, max. | 32 |
| Program alarms | Yes |
| Number of configurable program messages, max. | 10 000; Program messages are generated by the "Program_Alarm" block, ProDiag or GRAPH |
| Number of simultaneously active program alarms | 1 000 |
| Number of program alarms | 1 000 |
| Number of alarms for system diagnostics | 200 |
| Number of alarms for motion technology objects | 160 |
Test commissioning functions
| Joint commission (Team Engineering) | Yes; Parallel online access possible for up to 10 engineering systems |
| Status block | Yes; Up to 8 simultaneously (in total across all ES clients) |
| Single step | Yes |
| Number of breakpoints | 8 |
| Profiling | Yes |
| Status/control variable | Yes |
| Variables | Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
| Number of variables, max. – — of which status variables, max. | 200; per job |
| Number of variables, max. – — of which control variables, max. | 200; per job |
| Number of variables, max. – Forcing | Yes |
| Number of variables, max. – Forcing, variables | Peripheral inputs/outputs |
| Number of variables, max. – Number of variables, max. | 200 |
| Number of variables, max. – present | Yes |
| Number of variables, max. – Number of entries, max. | 1 000 |
| Number of variables, max. – — of which powerfail-proof | 300 |
| Number of variables, max. – Number of configurable Traces | 4 |
| Number of variables, max. – Memory size per trace, max. | 512 kbyte |
Interrupts/diagnostics/status information
| RUN/STOP LED | Yes |
| ERROR LED | Yes |
| MAINT LED | Yes |
| Monitoring of the supply voltage (PWR-LED) | Yes |
| Connection display LINK TX/RX | Yes |
Supported technology objects
| Motion Control | Yes; Note: The number of technology objects affects the cycle time of the PLC program; selection guide via the TIA Selection Tool |
| Number of available Motion Control resources for technology objects | 6 000 |
| Required Motion Control resources – — per speed-controlled axis | 40 |
| Required Motion Control resources – — per positioning axis | 80 |
| Required Motion Control resources – — per synchronous axis | 160 |
| Required Motion Control resources – — per external encoder | 80 |
| Required Motion Control resources – — per output cam | 20 |
| Required Motion Control resources – — per cam track | 160 |
| Required Motion Control resources – — per probe | 40 |
| Positioning axis – — Number of positioning axes at motion control cycle of 4 ms (typical value) | 35 |
| Positioning axis – — Number of positioning axes at motion control cycle of 8 ms (typical value) | 75 |
| Controller – PID_Compact | Yes; Universal PID controller with integrated optimization |
| Controller – PID_3Step | Yes; PID controller with integrated optimization for valves |
| Controller – PID-Temp | Yes; PID controller with integrated optimization for temperature |
| Counting and measuring – High-speed counter | Yes |
Standards, approvals, certificates
| CE mark | Yes |
| CSA approval | No |
| cULus | Yes |
| FM approval | No |
| RCM (formerly C-TICK) | No |
Ambient conditions
| horizontal installation, min. | -30 °C; No condensation |
| horizontal installation, max. | 55 °C; from 50 °C with max. 32 ET 200SP modules and 3x 300 mA USB load, M.2 SATA card max. 10 % load, no 3D graphics, no power supply of additional devices via power plug |
| vertical installation, min. | -30 °C; No condensation |
| vertical installation, max. | 45 °C; from 40 °C with max. 32 ET 200SP modules and 3x 300 mA USB load, M.2 SATA card max. 10 % load, no 3D graphics, no power supply of additional devices via power plug |
| min. | -40 °C |
| max. | 70 °C |
| Installation altitude above sea level, max. | 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
| Operation, tested according to IEC 60068-2-6 | Yes |
| Transport, tested acc. to IEC 60068-2-6 | Yes |
| tested according to IEC 60068-2-6 | Yes |
| tested according to IEC 60068-2-27 | Yes |
| tested according to IEC 60068-2-29 | Yes |
| Storage/transport, tested acc. to IEC 60068-2-27 | Yes |
Operating systems
| pre-installed operating system | Windows 10 IoT Enterprise 2021 LTSC |
Configuration
| — LAD | Yes |
| — FBD | Yes |
| — STL | Yes |
| — SCL | Yes |
| — CFC | Yes |
| — GRAPH | Yes |
| User program protection/password protection | Yes |
| Copy protection | Yes |
| Block protection | Yes |
| protection of confidential configuration data | Yes |
| Protection level: Write protection | Yes |
| Protection level: Read/write protection | Yes |
| Protection level: Complete protection | Yes |
| User administration | Yes; device-wide and centralized |
| Number of users | 100 |
| Number of groups | 100 |
| Number of roles | 50 |
| lower limit | adjustable minimum cycle time |
| upper limit | adjustable maximum cycle time |
| Size of ODK SO file, max. | 5.8 Mbyte |
Dimensions
| Width | 160 mm |
| Height | 117 mm |
| Depth | 75 mm |
Weights
| Weight, approx. | 0.83 kg |
Downloads & documentation
Official documents from Siemens, downloaded directly from the manufacturer.
Data sheets & manuals
6ES7677-2DD42-0GB0: frequently asked questions
When can 6ES7677-2DD42-0GB0 be shipped?
6ES7677-2DD42-0GB0 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 6ES7677-2DD42-0GB0 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 6ES7677-2DD42-0GB0 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6ES7677-2DD42-0GB0, subject to availability and destination.
More Siemens parts