Siemens 6EP4135-0GE00-0AY0

SITOP BAT1600 24 V DC 12 Ah Pb battery module with maintenance- fee closed lead-acid battery for SITOP UPS1600

MPN
6EP4135-0GE00-0AY0
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Siemens parts? We buy surplus →

What is the Siemens 6EP4135-0GE00-0AY0?

SITOP BAT1600 24 V DC 12 Ah Pb battery module with maintenance- fee closed lead-acid battery for SITOP UPS1600

Specifications

General information

Technical Product Detail Pagehttps://i.siemens.com/1P6EP4135-0GE00-0AY0
product brand nameSITOP
product type designationBAT1600
product designation12 Ah Pb
type of batterymaintenance-free lead-acid batteries
product versionExtension module/battery module

electrical data

end-of-charge voltage at DC — at -10 °C recommended28 V
end-of-charge voltage at DC — at 0 °C recommended28 V
end-of-charge voltage at DC — at 10 °C recommended27.8 V
end-of-charge voltage at DC — at 20 °C recommended27.3 V
end-of-charge voltage at DC — at 30 °C recommended26.8 V
end-of-charge voltage at DC — at 40 °C recommended26.6 V
end-of-charge voltage at DC — at 50 °C recommended26.3 V

output

battery capacity12 A·h
output current rated value40 A
output current in buffering mode maximum40 A
peak current120 A; for 30 ms
charging current maximum3 A
output voltage at DC rated value24 V

interfaces

communication functionYes

protection and monitoring

design of short-circuit protection50A / 32V Maxi flat fuse
design of the overload protectionValve control
display version for normal operationThree-color: green = Buffer ready; yellow = Buffer endangered; red = Buffer not possible

safety

operating resource protection classClass III
protection class IPIP20

standards, specifications, approvals

certificate of suitability — CE markingYes
certificate of suitability — UL approvalYes; cULus-Listed (UL 61010-1, UL61010-2-201 , CSA C22.2 No. 61010-1, CSA C22.2 NO 61010-2-201), File E143289
certificate of suitability — UKCA markingYes
type of certification CB-certificateYes

standards, specifications, approvals hazardous environments

certificate of suitability — ATEXNo

standards, specifications, approvals marine classification

shipbuilding approvalYes
Marine classification association — American Bureau of Shipping Europe Ltd. (ABS)Yes
Marine classification association — Det Norske Veritas (DNV)in preparation

standards, specifications, approvals Environmental Product Declaration

Environmental Product DeclarationYes
global warming potential [CO2 eq] — total40.18 kg
global warming potential [CO2 eq] — during manufacturing22.2 kg
global warming potential [CO2 eq] — during operation14 kg
global warming potential [CO2 eq] — after end of life1.17 kg

ambient conditions

ambient conditionFor storage, mounting and operation of lead-acid batteries, the relevant DIN/VDE regulations or country-specific regulations (e.g. VDE 0510 Part 2/EN 50272-2) must be observed. You must ensure that the battery site is sufficiently ventilated. Possible sources of ignition must be at least 50 cm away.
ambient temperature — during operation-15 ... +50 °C
ambient temperature — during transport-20 ... +50 °C
ambient temperature — during storage-20 ... +40 °C
relative temporary capacity loss at 20 °C in a month typical3 %

service life

service life of energy storage — typicalcapacity falls to 80 % of original capacity (according to EUROBAT)
service life of energy storage — at 20 °C typical4 a
service life of energy storage — at 30 °C typical2 a
service life of energy storage — at 40 °C typical1 a
service life of energy storage — at 50 °C typical0.5 a
noteAlong with the storage and operating temperature, other factors such as the duration of the storage period and the charge status during storage have a decisive influence on the possible useful life. Batteries should therefore be stored as briefly as possible, always fully charged, and within the temperature range 0 to +20 °C.

connection method

type of electrical connectionscrew terminal
type of electrical connection — for UPS module1 screw terminal each for 0.5 ... 16 mm² for + BAT and - BAT
type of electrical connection — for control circuit and status message1 screw terminal each for 0.2 ... 2.5 mm²

mechanical data

width × height × depth of the enclosure225 × 156 × 138 mm
installation width × mounting height225 mm × 256 mm
required spacing — top50 mm
required spacing — bottom50 mm
required spacing — left0 mm
required spacing — right0 mm
fastening methodWall mounting
fastening method — DIN-rail mountingNo
fastening method — S7 rail mountingNo
fastening method — wall mountingYes
net weight10.2 kg
number of cells2

accessories

product component included2x Maxi Fuse 50 A/32 V

further information internet links

internet link — to website: Industry Mallhttps://mall.industry.siemens.com
internet link — to web page: selection aid TIA Selection Toolhttps://www.siemens.com/tstcloud
internet link — to web page: power supplieshttps://siemens.com/sitop
internet link — to website: CAx-Download-Managerhttps://www.siemens.com/cax
internet link — to website: Industry Online Supporthttps://support.industry.siemens.com

additional information

other informationSpecifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified)

security information

security informationSiemens provides products and solutions with industrial cybersecurity functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement - and continuously maintain - a holistic, state-of-the-art industrial cybersecurity concept. Siemens’ products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place. For additional information on industrial cybersecurity measures that may be implemented, please visit www.siemens.com/cybersecurity-industry. Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customer’s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Cybersecurity RSS Feed under https://www.siemens.com/cert. (V4.7)

Downloads & documentation

Official documents from Siemens, downloaded directly from the manufacturer.

Data sheets & manuals

6EP4135-0GE00-0AY0: frequently asked questions

When can 6EP4135-0GE00-0AY0 be shipped?

6EP4135-0GE00-0AY0 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 6EP4135-0GE00-0AY0 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 6EP4135-0GE00-0AY0 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6EP4135-0GE00-0AY0, subject to availability and destination.

More Siemens parts

Siemens 6EP4134-3AB00-0AY0 – SITOP UPS1600 10 A uninterruptible power supply input: 24 V DC output: 24 V DC/10 A
Siemens
6EP4134-3AB00-0AY0

SITOP UPS1600 10 A uninterruptible power supply input: 24 V…

Siemens 6EP4134-3AB00-1AY0 – SITOP UPS1600 10 A USB uninterruptible power supply with USB interface input: 24 V DC output: 24 V DC/10 A
Siemens
6EP4134-3AB00-1AY0

SITOP UPS1600 10 A USB uninterruptible power supply with…

Siemens 6EP4134-3AB00-2AY0 – SITOP UPS1600 10 A Ethernet/ PROFINET uninterruptible power supply with Ethernet/ PROFINET interface / OPC UA…
Siemens
6EP4134-3AB00-2AY0

SITOP UPS1600 10 A Ethernet/ PROFINET uninterruptible power…

Siemens 6EP4135-0GL00-0AY0 – SITOP BAT1600 EX 24 V DC 12 Ah Pb battery module with maintenance- free closed lead-acid battery for SITOP…
Siemens
6EP4135-0GL00-0AY0

SITOP BAT1600 EX 24 V DC 12 Ah Pb battery module with…

Siemens 6EP4135-0HA00-0AY0 – SITOP CAS1600 0.5 Ah 24 V DC 0.5 Ah SuCAP capacitor module with maintenance- free sealed supercapacitors for…
Siemens
6EP4135-0HA00-0AY0

SITOP CAS1600 0.5 Ah 24 V DC 0.5 Ah SuCAP capacitor module…

Siemens 6EP4136-0HA00-0AY0 – SITOP CAS1600 1.3 Ah 24 V DC 1.3 Ah LiCAP capacitor module with maintenance- free sealed supercapacitors for…
Siemens
6EP4136-0HA00-0AY0

SITOP CAS1600 1.3 Ah 24 V DC 1.3 Ah LiCAP capacitor module…

Siemens 6EP4135-0GE00-0AY0Price and lead time confirmed within 1 business day