Siemens 6EP3333-3SA00-0AY0
SITOP PSU2200/1AC/24VDC/5A SITOP PSU2200 STABILIZED POWER SUPPLY PSU2200 INPUT: 100-240 V AC output: 24 V…
- MPN
- 6EP3333-3SA00-0AY0
- Category
- Power Supplies
Request a Quote
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- Ships via
What is the Siemens 6EP3333-3SA00-0AY0?
SITOP PSU2200/1AC/24VDC/5A SITOP PSU2200 STABILIZED POWER SUPPLY PSU2200 INPUT: 100-240 V AC output: 24 V DC/5 A
Specifications
General information
| Technical Product Detail Page | https://i.siemens.com/1P6EP3333-3SA00-0AY0 |
| Technical Product Detail Page | https://i.siemens.com/1P6EP3333-3SA00-0AY0 |
| product brand name | SITOP |
| product type designation | PSU2200 |
| product designation | Power supply SITOP PSU2200 |
| type of current supply | 24 V/5 A |
input
| type of the power supply network | 1-phase AC |
| phase number | 1 |
| voltage curve at input | AC |
| supply voltage at AC — minimum rated value | 100 V |
| supply voltage at AC — maximum rated value | 240 V |
| supply voltage at AC — initial value | 90 V |
| supply voltage at AC — full-scale value | 264 V |
| supply voltage — at 50 Hz | 240 V |
| supply voltage — at 60 Hz | 120 V |
| line frequency | 50/60 Hz |
| line frequency | 47 ... 63 Hz |
| wide range input | Yes |
| buffering time for rated value of the output current in the event of power failure minimum | 45 ms |
| operating condition of the mains buffering | at Vin = 230 V |
| input current — at rated input voltage 115 V | 2 A |
| input current — at rated input voltage 230 V | 1.2 A |
| current limitation of inrush current at 25 °C maximum | 35 A |
| I2t value maximum | 2 A²·s |
| fuse protection type | internal |
| fuse protection type in the feeder | Recommended miniature circuit breaker: 16 A characteristic B |
output
| voltage curve at output | Controlled, isolated DC voltage |
| product function output voltage controlled | Yes |
| product function output voltage stabilized | Yes |
| output voltage at DC rated value | 24 V |
| output voltage adjustable | Yes; via potentiometer |
| adjustable output voltage | 21.6 ... 26.4 V |
| relative overall tolerance of the voltage | 1 % |
| relative control precision of the output voltage — on slow fluctuation of input voltage | 0.5 % |
| relative control precision of the output voltage — on slow fluctuation of ohm loading | 0.5 % |
| voltage peak — maximum | 450 mV |
| voltage peak — typical | 150 mV |
| display version for normal operation | Green LED for 24 V OK |
| behavior of the output voltage when switching on | Overshoot of Vout < 5 % |
| response delay maximum | 500 ms at 115 / 230 V AC |
| voltage increase time of the output voltage — typical | 30 ms |
| output current — rated value | 5 A |
| output current — rated range | 0 ... 5 A; +40 ... +70 °C: Derating 1.67%/K at 115 V AC; +50 ... +70 °C Derating 2.5%/K at 230 V AC |
| supplied active power typical | 120 W |
| bridging of equipment | No |
efficiency
| efficiency in percent | 88.5 % |
| power loss [W] — at rated output voltage for rated value of the output current typical | 16 W |
| power loss [W] — during no-load operation maximum | 0.15 W |
closed-loop control
| relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical | 1 % |
| relative control precision of the output voltage load step of resistive load 50/100/50 % typical | 10 % |
protection and monitoring
| design of the overvoltage protection | < 33.6 V (latch mode) |
| property of the output short-circuit proof | Yes |
| design of short-circuit protection | constant current characteristic (hiccup mode when Ua < 80%), automatic hot restart when the fault is fixed |
| design of the current limitation | 105-150% of rated load current and Uout > 80%, Constant current limit, Auto recovery |
safety
| galvanic isolation between input and output | Yes |
| galvanic isolation | Output voltage: SELV, ES1 (IEC 62368-1), DVC As (IEC 61204-7) |
| operating resource protection class | Class I |
| leakage current — maximum | 0.5 mA |
| protection class IP | IP20 |
EMC
| standard — for emitted interference | EN 55032 Class B |
| standard — for mains harmonics limitation | EN 61000-3-2 |
| standard — for interference immunity | EN 55035 |
standards, specifications, approvals
| certificate of suitability — CE marking | Yes |
| certificate of suitability — UL approval | No |
| certificate of suitability — UKCA marking | Yes |
| certificate of suitability — EAC approval | No |
| certificate of suitability — Regulatory Compliance Mark (RCM) | No |
| certificate of suitability — CCC approval | Yes |
| certificate of suitability — NEC Class 2 | No |
| type of certification — BIS | No |
| type of certification — CB-certificate | Yes |
| MTBF at 25 °C | 700 000 h; according to SR-332, 100% full load (24 V, 5 A), input voltage: 115 V / 230 V AC |
standards, specifications, approvals hazardous environments
| certificate of suitability — IECEx | No |
| certificate of suitability — ATEX | No |
| certificate of suitability — ULhazloc approval | No |
| certificate of suitability — FM registration | No |
standards, specifications, approvals marine classification
| shipbuilding approval | No |
| Marine classification association — American Bureau of Shipping Europe Ltd. (ABS) | No |
| Marine classification association — French marine classification society (BV) | No |
| Marine classification association — Det Norske Veritas (DNV) | No |
| Marine classification association — Lloyds Register of Shipping (LRS) | No |
ambient conditions
| ambient temperature — during operation | -30 ... +70 °C; With natural convection |
| ambient temperature — during transport | -40 ... +85 °C |
| ambient temperature — during storage | -40 ... +85 °C |
| environmental category according to IEC 60721 | Climate class 3K3, 20 ... 90% no condensation |
connection method
| type of electrical connection | screw terminal |
| at input | L, N, PE: screw terminal for 0.5 ... 6 mm² single-core/finely stranded |
| at output | +1, +2, -1, -2: screw terminal for 0.5 ... 6 mm² |
mechanical data
| width × height × depth of the enclosure | 30 × 124 × 117.2 mm |
| installation width × mounting height | 40 mm × 184 mm |
| required spacing — top | 40 mm |
| required spacing — bottom | 20 mm |
| required spacing — left | 5 mm |
| required spacing — right | 5 mm |
| fastening method | Snaps onto DIN rail EN 60715 35x7.5/15 |
| DIN-rail mounting | Yes |
| S7 rail mounting | No |
| wall mounting | No |
| housing can be lined up | No |
| net weight | 0.45 kg |
additional information
| other information | Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified) |
Downloads & documentation
Official documents from Siemens, downloaded directly from the manufacturer.
Data sheets & manuals
6EP3333-3SA00-0AY0: frequently asked questions
When can 6EP3333-3SA00-0AY0 be shipped?
6EP3333-3SA00-0AY0 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 6EP3333-3SA00-0AY0 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 6EP3333-3SA00-0AY0 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6EP3333-3SA00-0AY0, subject to availability and destination.