Siemens 6AG2647-8BE72-1HA1
SIPLUS IPC 227E ET rail based on 6ES7647-8BE72-7HA1 with conformal coating, -25…+60 °C
- MPN
- 6AG2647-8BE72-1HA1
- Category
- SIPLUS IPC227E ET RAIL
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Siemens 6AG2647-8BE72-1HA1?
SIPLUS IPC 227E ET rail based on 6ES7647-8BE72-7HA1 with conformal coating, -25…+60 °C, OT1 with ST1/2 (+70 °C für 10 minutes), 1x display port; 2x 10/100/1000 Mbps Ethernet RJ45; 1x USB3.0, 3x USB2.0; CFast slot; 24 V DC industrial power supply Celeron E3845 ET (4C/4T) with TPM (not for China); 4 GB ET with NVRAM; box: basic with COM 1/2; Windows 10 IoT Enterprise LTSB 2016, 64-bit, MUI (en, de, fr, it, es) 60 GB SSD ET, not exchangeable
Specifications
General information
| Product type designation | IPC227E |
| based on | 6ES7647-8BE72-7HA1 |
Installation type/mounting
| Mounting | DIN rail, wall mounting, portrait mounting |
| Design | Box PC, built-in unit |
Supply voltage
| Type of supply voltage | 24 V DC |
| Mains buffering — Mains/voltage failure stored energy time | 20 ms |
Processor
| Processor type | Intel Atom E3845 |
| Chipset | SoC |
Graphic
| Graphics controller | Integrated |
| Graphics card | Yes |
Drives
| SSD | Yes |
Storage
| Type of memory | DDR3L SO-DIMM |
| Capacity of main memory, max. | 4 Gbyte |
Data areas and their retentivity
| Retentive data area (incl. timers, counters, flags), max. | 512 kbyte; 128 KB can be stored in the buffer time; optional |
Hardware configuration
| Slots — Number of PCI slots | 0 |
| Slots — Number of PCI slots | 1; Optional |
| Slots — Number of compact flash slots | 1; CFast |
Interfaces
| Number of industrial Ethernet interfaces | 2; 2x Ethernet (RJ45) |
| Number of PROFINET interfaces | 2 |
| serial interface | Without / 2x COM (RS 232 / 422 / 485), selectable in the BIOS |
| Video interfaces — Graphics interface | 1x DisplayPort |
| Industrial Ethernet — Industrial Ethernet interface — 100 Mbps | Yes |
| Industrial Ethernet — Industrial Ethernet interface — 1000 Mbps | Yes |
Interrupts/diagnostics/status information
| LED status display | 1x power, 3x user |
Integrated Functions
| Monitoring functions — Temperature monitoring | Yes |
| Monitoring functions — Fan | No |
| Monitoring functions — Monitoring function via network | Optional |
Isolation
| Isolation tested with | 750 V DC (type test) and according to EN 50155 (routine test) |
Degree and class of protection
| IP degree of protection | IP40 |
| IP (rear) | IP40 |
Standards, approvals, certificates
| Railway application — EN 50121-3-2 | Yes; EMC for rail vehicles |
| Railway application — EN 50121-4 | Yes; EMC for signal and telecommunications systems |
| Railway application — EN 50124-1 | Yes; Railway applications - overvoltage category OV2; pollution degree PD2; rated surge voltage UNi = 0.5 kV; UNm = 24 V DC |
| Railway application — EN 50125-1 | Yes; Rail vehicles - see ambient conditions |
| Railway application — EN 50125-2 | Yes; Stationary electrical equipment - see ambient conditions |
| Railway application — EN 50125-3 | Yes; Signal and telecommunications systems - see ambient conditions; vibrations and shocks: Application point outside of tracks (1 m to 3 m away from track) |
| Railway application — EN 50155 | Yes; Rail vehicles - temperature class OT1, ST1/ST2, horizontal mounting position |
| Railway application — EN 61373 | Yes; Rail vehicles - vibrations and shocks: Category 1 Class A/B |
| Railway application — Fire protection acc. to EN 45545-2 | Yes; For proof of conformity, see Service & Support |
Ambient conditions
| Ambient temperature during operation — min. | -25 °C; = Tmin (incl. condensation/frost) |
| Ambient temperature during operation — max. | 60 °C; = Tmax; +70 °C for 10 min (OT1, ST1/ST2 acc. to EN 50155) |
| Ambient temperature during storage/transportation — min. | -20 °C |
| Ambient temperature during storage/transportation — max. | 60 °C |
| Altitude during operation relating to sea level — Installation altitude above sea level, max. | 2 000 m |
| Altitude during operation relating to sea level — Ambient air temperature-barometric pressure-altitude | Tmin ... Tmax at 1 140 hPa ... 795 hPa (-1 000 m ... +2 000 m) |
| Relative humidity — With condensation, tested in accordance with IEC 60068-2-38, max. | 100 %; RH incl. condensation / frost (no commissioning in bedewed state), horizontal installation |
| Vibrations — Vibration resistance during operation acc. to IEC 60068-2-6 | tested to DIN IEC 60068-2-6: 10 Hz to 58 Hz: 0.075 mm, 58 Hz to 200 Hz: 9.8 m/s² (1 g) |
| Resistance — Coolants and lubricants — Resistant to commercially available coolants and lubricants | Yes; Incl. diesel and oil droplets in the air |
| Resistance — Use in stationary industrial systems — to biologically active substances according to EN 60721-3-3 | Yes; Class 3B2 mold, fungus and dry rot spores (with the exception of fauna); Class 3B3 on request |
| Resistance — Use in stationary industrial systems — to chemically active substances according to EN 60721-3-3 | Available soon |
| Resistance — Use in stationary industrial systems — to mechanically active substances according to EN 60721-3-3 | Yes; Class 3S4 incl. sand, dust, * |
| Resistance — Use on land craft, rail vehicles and special-purpose vehicles — to biologically active substances according to EN 60721-3-5 | Yes; Class 5B2 mold, fungus and dry rot spores (with the exception of fauna); Class 5B3 on request |
| Resistance — Use on land craft, rail vehicles and special-purpose vehicles — to chemically active substances according to EN 60721-3-5 | in preparation |
| Resistance — Use on land craft, rail vehicles and special-purpose vehicles — to mechanically active substances according to EN 60721-3-5 | Yes; Class 5S3 incl. sand, dust; * |
| Resistance — Usage in industrial process technology — Against chemically active substances acc. to EN 60654-4 | in preparation |
| Resistance — Usage in industrial process technology — Environmental conditions for process, measuring and control systems acc. to ANSI/ISA-71.04 | in preparation |
| Resistance — Remark — Note regarding classification of environmental conditions acc. to EN 60721, EN 60654-4 and ANSI/ISA-71.04 | * The supplied plug covers must remain in place over the unused interfaces during operation! |
| Conformal coating — Coatings for printed circuit board assemblies acc. to EN 61086 | Yes; Class 2 for high reliability |
| Conformal coating — Protection against fouling acc. to EN 60664-3 | Yes; Type 1 protection |
| Conformal coating — Electronic equipment on rolling stock acc. to EN 50155 | Yes; Class PC2 protective coating acc. to EN 50155:2017 |
| Conformal coating — Military testing according to MIL-I-46058C, Amendment 7 | Yes; Discoloration of coating possible during service life |
| Conformal coating — Qualification and Performance of Electrical Insulating Compound for Printed Board Assemblies according to IPC-CC-830A | Yes; Conformal coating, Class A |
Operating systems
| pre-installed operating system | Windows 10 IoT Enterprise 2016 LTSB, 64bit, MUI |
| without operating system | Yes; Optional |
| pre-installed operating system — Windows 7 | Yes; Ultimate 32 bit or 64 bit |
| pre-installed operating system — Windows 10 Enterprise | Yes; Windows 10 Enterprise 2016 LTSB, 64 bit, MUI |
Dimensions
| Width | 191 mm |
| Height | 100 mm |
| Depth | 60 mm |
Other
| Note: | for use in railway applications, also observe the product information "SIPLUS extreme RAIL" A5E37661960A, Online Support article 109736776 |
No matching specifications
Downloads & documentation
Official documents from Siemens, downloaded directly from the manufacturer.
Data sheets & manuals
6AG2647-8BE72-1HA1: frequently asked questions
When can 6AG2647-8BE72-1HA1 be shipped?
6AG2647-8BE72-1HA1 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 6AG2647-8BE72-1HA1 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 6AG2647-8BE72-1HA1 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 6AG2647-8BE72-1HA1, subject to availability and destination.