Siemens 3RK3922-1AC10

Starter package for modular Safety system 3RK3 Content: Central unit MSS Advanced connection: Screw terminal…

MPN
3RK3922-1AC10
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Siemens parts? We buy surplus →

What is the Siemens 3RK3922-1AC10?

Starter package for modular Safety system 3RK3 Content: Central unit MSS Advanced connection: Screw terminal Software Safety ES V1.0 Premium, USB PC cable

Specifications

General technical data

product function – EMERGENCY STOP functionYes
product function – protective door monitoringYes
product function – protective door monitoring with tumblerYes
product function – muting, 2 sensor-parallelYes
product function – muting, 4 sensor-parallelYes
product function – muting, 4 sensor-sequentialYes
product function – monitoring parameterizableYes
product function – evaluation: electro-sensitive protective equipmentYes
product function – evaluation: selector switchYes
product function – pressure-sensitive mat monitoringYes
product function – evaluation: two-hand operator panelYes
product function – evaluation: enabling switchYes
product function – monitored start-upYes
product function – two-hand control according to EN 574Yes
number of function blocks typical300
insulation voltage rated value300 V
degree of pollution3
surge voltage resistance rated value2 500 V
consumed current for rated value of supply voltage1.685 A
protection class IP – of the enclosureIP20
protection class IP – of the terminalIP20
shock resistance15 g / 11 ms
vibration resistance according to IEC 60068-2-65 ... 500 Hz: 0.75 mm
operating frequency maximum1 000 1/h
mechanical service life (operating cycles) typical10 000 000
reference code according to IEC 81346-2K
Substance Prohibitance (day/month/year)07/01/2006
SVHC substance nameLead CAS-No. 7439-92-1 Lead monoxide (lead oxide) CAS-No. 1317-36-8 2-methyl-1-(4-methylthiophenyl)-2-morpholinopropan-1-one CAS-No. 71868-10-5 Melamine CAS-No. 108-78-1 6,6'-di-tert-butyl-2,2'-methylenedi-p-cresol CAS-No. 119-47-1 Diboron trioxide CAS-No. 1303-86-2
Net Weight0.81 kg
product function suitable for AS-i Power24VYes
product function diagnostics with CTT2 deviceYes
number of safe signals for remote shutdown or cross traffic by means of AS-interface12
consumed current from profile conductors of the AS-Interface – at 30 V maximum45 mA
consumed current from profile conductors of the AS-Interface – at 24 V with AS-i Power24V maximum45 mA

Ambient conditions

installation altitude at height above sea level maximum2 000 m
ambient temperature – during operation-20 ... +60 °C
ambient temperature – during storage-40 ... +85 °C
ambient temperature – during transport-40 ... +85 °C
air pressure according to SN 3120570 ... 106 kPa

Electromagnetic compatibility

installation environment regarding EMCThis product is suitable for Class A environments only. In household environments, this device can cause unwanted radio interference. The user is required to implement appropriate measures in this case.
conducted interference – due to burst according to IEC 61000-4-42 kV (power ports) / 1 kV (signal ports)
conducted interference – due to conductor-earth surge according to IEC 61000-4-52 kV
conducted interference – due to conductor-conductor surge according to IEC 61000-4-51 kV
field-based interference according to IEC 61000-4-310 V/m
electrostatic discharge according to IEC 61000-4-24 kV contact discharge / 8 kV air discharge

Safety related data

diagnostics test interval by internal test function maximum1 000 s
stop category according to IEC 60204-10 / 1
category according to EN 954-14
SIL Claim Limit (subsystem) according to EN 62061Kat. 4 / SIL3 / Ple
Safety Integrity Level (SIL) – according to IEC 62061SIL 3
PFHD with high demand rate – according to IEC 620617E-9 1/h
performance level (PL) according to EN ISO 13849-1e
category according to EN ISO 13849-14
performance level (PL) – according to ISO 13849-1PL e
Safety Integrity Level (SIL) – according to IEC 615083
hardware fault tolerance – according to IEC 615081
T1 value – for proof test interval or service life according to IEC 6150820 a
touch protection against electrical shockfinger-safe

Short-circuit protection

design of the fuse link for short-circuit protection of the NO contacts of the relay outputs requiredNH Type 3NA, DIAZED Type 5SB, NEOZED Type 5SE

Inputs/ Outputs

product function – parameterizable inputsYes
product function – parameterizable outputsYes
number of inputs – safety-related8
number of inputs – non-safety-related0
input delay time0 ... 150 ms
ingress aquisition time at digital input maximum60 ms
input delay time at digital input maximum150 ms
number of outputs – safety-related 2-channel2
number of outputs – for testing contact-based sensors2
number of outputs as contact-affected switching element safety-related – 1-channel0
number of outputs as contact-affected switching element safety-related – 2-channel1
number of outputs as contact-less semiconductor switching element – safety-related 2-channel1
number of outputs as contact-less semiconductor switching element – non-safety-related0
design of the contactless switching element safety-relatedP potential
pulse duration of the contactless semiconductor contact block for switching off safety-related maximum1 ms
recovery time of the safe outputs420 ms
dark period of the common drivers1 ms
switching capacity current of semiconductor outputs at DC-13 at 24 V1.5 A

Communication/ Protocol

protocol optional is supported – PROFIBUS DP protocolYes; when using the DP interface module; 64 bit cyclical data
protocol is supported AS-Interface protocolYes

Control circuit/ Control

type of voltageDC
operating range factor control supply voltage rated value at DC – initial value0.85
operating range factor control supply voltage rated value at DC – full-scale value1.15
inrush current peak – at 24 V70 A
duration of inrush current peak – at 24 V1 ms
operating power rated value4.5 W

Installation/ mounting/ dimensions

mounting positionvertical
fastening methodSnap-mounted to DIN rail or screw-mounted with additional push-in lug
height111 mm
width45 mm
depth124 mm

Connections/ Terminals

product function removable terminalYes
type of electrical connectionscrew terminal
type of connectable conductor cross-sections – solid1x (0.5 ... 4.0mm²), 2x (0.5 ... 2.5 mm²)
type of connectable conductor cross-sections – finely stranded with core end processing1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²)
type of connectable conductor cross-sections – for AWG cables solid2x (20 ... 14)
type of connectable conductor cross-sections – for AWG cables stranded2x (20 ... 14)
connectable conductor cross-section finely stranded with core end processing0.5 ... 2.5 mm²
AWG number as coded connectable conductor cross section – solid20 ... 14
AWG number as coded connectable conductor cross section – stranded20 ... 14
DC resistance of the cable maximum100 Ω

Downloads & documentation

Official documents from Siemens, downloaded directly from the manufacturer.

Data sheets & manuals

3RK3922-1AC10: frequently asked questions

When can 3RK3922-1AC10 be shipped?

3RK3922-1AC10 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 3RK3922-1AC10 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 3RK3922-1AC10 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 3RK3922-1AC10, subject to availability and destination.

More Siemens parts

Siemens 3RK3131-1AC10 – SIRIUS, central unit 3RK3 Advanced for modular safety system 3RK3 4/8 F-DI, 1F-RO, 1 F-DO
Siemens
3RK3131-1AC10

SIRIUS, central unit 3RK3 Advanced for modular safety…

Siemens 3RK3251-2AA10 – SIRIUS, expansion module 3RK32 for modular safety system 3RK3 4/8 F-RO
Siemens
3RK3251-2AA10

SIRIUS, expansion module 3RK32 for modular safety system…

Siemens 3RK3511-1BA10 – SIRIUS, interface module DP interface, for modular safety system 3RK3 PROFIBUS DP interface 12 Mbps
Siemens
3RK3511-1BA10

SIRIUS, interface module DP interface

Siemens 3RK3511-2BA10 – SIRIUS, interface module DP interface, for modular safety system 3RK3 PROFIBUS DP interface 12 Mbps
Siemens
3RK3511-2BA10

SIRIUS, interface module DP interface

Siemens 3RK7271-1AA30-0AA0 – SIMATIC S7-1200, DCM 1271 Data decoupling module for AS-i Master CM 1243-2 IN: 24 V / 30 V DC OUT: 1x…
Siemens
3RK7271-1AA30-0AA0

SIMATIC S7-1200, DCM 1271 Data decoupling module for AS-i…

Siemens 3RM1001-1AA04 – Direct starter, 3RM1, 500 V, 0 - 0.12 kW, 0.1 - 0.5 A, 24 V DC, screw terminals
Siemens
3RM1001-1AA04

Direct starter, 3RM1, 500 V, 0 - 0.12 kW, 0.1 - 0.5 A

Siemens 3RM1001-1AA14 – Direct starter, 3RM1, 500 V, 0 - 0.12 kW, 0.1 - 0.5 A, 110-230 V AC, screw terminals
Siemens
3RM1001-1AA14

Direct starter, 3RM1, 500 V, 0 - 0.12 kW, 0.1 - 0.5 A

Siemens 3RM1001-3AA04 – Direct-on-line starter, 3RM1, 500 V, 0 - 0.12 kW, 0.1 - 0.5 A, 24 V DC
Siemens
3RM1001-3AA04

Direct-on-line starter, 3RM1, 500 V, 0 - 0.12 kW

Siemens 3RK3922-1AC10Price and lead time confirmed within 1 business day
Request a Quote