Siemens 3RH2131-1VB40-Z W97 – Coupling contactor relay, 3 NO + 1 NC, 24 V DC

MPN: 3RH2131-1VB40-Z W97 · Brand: Siemens
Price on request
Request a Quote

A real person replies, typically within 1 business day — see our privacy policy.

12-month warranty (new) · 3-month (used/refurbished)
30-day returns, no restocking fee on unused parts
Ships via

Quick facts

AvailabilityConfirmed on request
CategoryCircuit Protection & Switching
LifecycleActive
Warranty12-month (new) · 3-month (used/refurbished)
Weight0.29 kg
DatasheetManufacturer datasheet ↗

Shipping & availability

When can 3RH2131-1VB40-Z W97 be shipped?

3RH2131-1VB40-Z W97 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up 3RH2131-1VB40-Z W97 in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for 3RH2131-1VB40-Z W97 and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 3RH2131-1VB40-Z W97, subject to availability and destination.

coupling contactor relay, 3 NO + 1 NC, 24 V DC, 0.85-1.85* Us, with integrated diode, screw terminal, frame size S00, multi-unit packaging, pack = 40 units

Specifications

General technical data

size of contactorS00
product extension auxiliary switchNo
power loss [W] for rated value of the current without load current share typical1.6 W
insulation voltage with degree of pollution 3 at AC rated value690 V
degree of pollution3
surge voltage resistance rated value6 kV
shock resistance at rectangular impulse – at DC10 g / 5 ms, 5 g / 10 ms
shock resistance with sine pulse – at DC15 g / 5 ms, 8 g / 10 ms
mechanical service life (operating cycles) – of contactor typical30 000 000
reference code according to IEC 81346-2K
Substance Prohibitance (day/month/year)10/01/2009
SVHC substance nameLead CAS-No. 7439-92-1
Net Weight0.279 kg

Ambient conditions

installation altitude at height above sea level maximum2 000 m
ambient temperature – during operation-25 ... +50 °C
ambient temperature – during storage-55 ... +80 °C
relative humidity minimum10 %
relative humidity at 55 °C according to IEC 60068-2-30 maximum95 %

Main circuit

no-load switching frequency – at AC10 000 1/h
no-load switching frequency – at DC10 000 1/h

Control circuit/ Control

type of voltage of the control supply voltageDC
control supply voltage at DC rated value24 V
operating range factor control supply voltage rated value of magnet coil at DC – initial value0.85
operating range factor control supply voltage rated value of magnet coil at DC – full-scale value1.85
design of the surge suppressordiode
closing power of magnet coil at DC1.6 W
holding power of magnet coil at DC1.6 W
closing delay – at DC25 ... 120 ms
opening delay – at DC20 ... 80 ms
arcing time10 ... 15 ms

Auxiliary circuit

number of NC contacts for auxiliary contacts1
instantaneous contact1
number of NO contacts for auxiliary contacts3
instantaneous contact3
identification number and letter for switching elements31 E
operational current at AC-12 maximum10 A
operational current at AC-15 – at 230 V rated value10 A
operational current at AC-15 – at 400 V rated value3 A
operational current at AC-15 – at 500 V rated value2 A
operational current at AC-15 – at 690 V rated value1 A
operational current at 1 current path at DC-12 – at 24 V rated value10 A
operational current at 1 current path at DC-12 – at 60 V rated value6 A
operational current at 1 current path at DC-12 – at 110 V rated value3 A
operational current at 1 current path at DC-12 – at 220 V rated value1 A
operational current at 1 current path at DC-12 – at 440 V rated value0.3 A
operational current at 1 current path at DC-12 – at 600 V rated value0.15 A
operational current with 2 current paths in series at DC-12 – at 24 V rated value10 A
operational current with 2 current paths in series at DC-12 – at 60 V rated value10 A
operational current with 2 current paths in series at DC-12 – at 110 V rated value4 A
operational current with 2 current paths in series at DC-12 – at 220 V rated value2 A
operational current with 2 current paths in series at DC-12 – at 440 V rated value1.3 A
operational current with 2 current paths in series at DC-12 – at 600 V rated value0.65 A
operational current with 3 current paths in series at DC-12 – at 24 V rated value10 A
operational current with 3 current paths in series at DC-12 – at 60 V rated value10 A
operational current with 3 current paths in series at DC-12 – at 110 V rated value10 A
operational current with 3 current paths in series at DC-12 – at 220 V rated value3.6 A
operational current with 3 current paths in series at DC-12 – at 440 V rated value2.5 A
operational current with 3 current paths in series at DC-12 – at 600 V rated value1.8 A
operating frequency at DC-12 maximum1 000 1/h
operational current at 1 current path at DC-13 – at 24 V rated value10 A
operational current at 1 current path at DC-13 – at 60 V rated value2 A
operational current at 1 current path at DC-13 – at 110 V rated value1 A
operational current at 1 current path at DC-13 – at 220 V rated value0.3 A
operational current at 1 current path at DC-13 – at 440 V rated value0.14 A
operational current at 1 current path at DC-13 – at 600 V rated value0.1 A
operational current with 2 current paths in series at DC-13 – at 24 V rated value10 A
operational current with 2 current paths in series at DC-13 – at 60 V rated value3.5 A
operational current with 2 current paths in series at DC-13 – at 110 V rated value1.3 A
operational current with 2 current paths in series at DC-13 – at 220 V rated value0.9 A
operational current with 2 current paths in series at DC-13 – at 440 V rated value0.2 A
operational current with 2 current paths in series at DC-13 – at 600 V rated value0.1 A
operational current with 3 current paths in series at DC-13 – at 24 V rated value10 A
operational current with 3 current paths in series at DC-13 – at 60 V rated value4.7 A
operational current with 3 current paths in series at DC-13 – at 110 V rated value3 A
operational current with 3 current paths in series at DC-13 – at 220 V rated value1.2 A
operational current with 3 current paths in series at DC-13 – at 440 V rated value0.5 A
operational current with 3 current paths in series at DC-13 – at 600 V rated value0.26 A
operating frequency at DC-13 maximum1 000 1/h
contact reliability of auxiliary contacts1 faulty switching per 100 million (17 V, 1 mA)

UL/CSA ratings

contact rating of auxiliary contacts according to ULA600 / Q600

Short-circuit protection

design of the miniature circuit breaker for short-circuit protection of the auxiliary circuit up to 230 VC characteristic: 10 A; 0.4 kA
design of the fuse link for short-circuit protection of the auxiliary switch requiredgG: 10 A (690 V, 1 kA)

Installation/ mounting/ dimensions

mounting position+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface
fastening methodscrew and snap-on mounting onto 35 mm DIN rail
height57.5 mm
width45 mm
depth73 mm
with side-by-side mounting – — forwards10 mm
with side-by-side mounting – — upwards10 mm
with side-by-side mounting – — downwards10 mm
with side-by-side mounting – — at the side0 mm
for grounded parts – — forwards10 mm
for grounded parts – — upwards10 mm
for grounded parts – — at the side6 mm
for grounded parts – — downwards10 mm
for live parts – — forwards10 mm
for live parts – — upwards10 mm
for live parts – — downwards10 mm
for live parts – — at the side6 mm

Connections/ Terminals

type of electrical connection for auxiliary and control circuitscrew-type terminals
for auxiliary contacts – — solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
for auxiliary contacts – — finely stranded with core end processing2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
for auxiliary contacts – for AWG cables for auxiliary contacts2x (20 ... 16), 2x (18 ... 14), 2x 12

Safety related data

product function – positively driven operation according to IEC 60947-5-1Yes
product function – suitable for safety functionYes
suitability for use safety-related switching OFFYes
service life maximum20 a
proportion of dangerous failures – with low demand rate according to SN 3192040 %
proportion of dangerous failures – with high demand rate according to SN 3192073 %
B10 value with high demand rate according to SN 319201 000 000; With 0.3 x Ie
failure rate [FIT] with low demand rate according to SN 31920100 FIT
device type according to ISO 13849-13
overdimensioning according to ISO 13849-2 necessaryYes
safety device type according to IEC 61508-2Type A
protection class IP on the front according to IEC 60529IP20
touch protection on the front according to IEC 60529finger-safe, for vertical contact from the front

Downloads & documentation

Official documents from Siemens, downloaded directly from the manufacturer.

Data sheets & manuals

Product data sheet 3RH2131-1VB40PDF
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Siemens parts

Siemens 3RH2131-1MB40-0KT0 – Coupling contactor relay, 3 NO + 1 NC, 24 V DCAvailable on requestSiemens 3RH2131-1MB40-0KT0 – Coupling contactor relay, 3 NO + 1 NC, 24 V DC
MPN: 3RH2131-1MB40-0KT0 · Siemens
Price on request
Request a quote
Siemens 3RH2131-1SB40 – Coupling contactor relay, 3 NO + 1 NC, 24 V DCAvailable on requestSiemens 3RH2131-1SB40 – Coupling contactor relay, 3 NO + 1 NC, 24 V DC
MPN: 3RH2131-1SB40 · Siemens
Price on request
Request a quote
Siemens 3RH2131-1VB40 – Coupling contactor relay, 3 NO + 1 NC, 24 V DCAvailable on requestSiemens 3RH2131-1VB40 – Coupling contactor relay, 3 NO + 1 NC, 24 V DC
MPN: 3RH2131-1VB40 · Siemens
Price on request
Request a quote
Siemens 3RH2131-1VB40-Z W96 – Coupling contactor relay, 3 NO + 1 NC, 24 V DCAvailable on requestSiemens 3RH2131-1VB40-Z W96 – Coupling contactor relay, 3 NO + 1 NC, 24 V DC
MPN: 3RH2131-1VB40-Z W96 · Siemens
Price on request
Request a quote
Siemens 3RH2131-1VB40-Z X95 – Coupling contactor relay, 3 NO + 1 NC, 24 V DCAvailable on requestSiemens 3RH2131-1VB40-Z X95 – Coupling contactor relay, 3 NO + 1 NC, 24 V DC
MPN: 3RH2131-1VB40-Z X95 · Siemens
Price on request
Request a quote
Siemens 3RH2131-1WB40 – Coupling contactor relay, 3 NO + 1 NC, 24 V DCAvailable on requestSiemens 3RH2131-1WB40 – Coupling contactor relay, 3 NO + 1 NC, 24 V DC
MPN: 3RH2131-1WB40 · Siemens
Price on request
Request a quote
Siemens 3RH2131-1XB40-0LA2 – Contactor relay railway, 3 NO + 1 NC, 24-34 V DCAvailable on requestSiemens 3RH2131-1XB40-0LA2 – Contactor relay railway, 3 NO + 1 NC, 24-34 V DC
MPN: 3RH2131-1XB40-0LA2 · Siemens
Price on request
Request a quote
Siemens 3RH2131-1XF40-0LA2 – Contactor relay railway, 3 NO + 1 NC, 72-125 V DCAvailable on requestSiemens 3RH2131-1XF40-0LA2 – Contactor relay railway, 3 NO + 1 NC, 72-125 V DC
MPN: 3RH2131-1XF40-0LA2 · Siemens
Price on request
Request a quote