Schneider Electric TM168D23AHU101C – Base Built - in Display M168 - 23 IO - BMS connectivity
Discontinued by Schneider Electric — we can still source the original TM168D23AHU101C (new, used or refurbished, subject to availability). Request a quote below.
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Modicon M168 |
| Lifecycle | Discontinued |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Country of origin | IT |
| UPC / EAN | 3595864109374 |
| Datasheet | Manufacturer datasheet ↗ |
Shipping & availability
Can I still buy the TM168D23AHU101C now that it is discontinued?
Yes. Schneider Electric has discontinued the TM168D23AHU101C, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time.
When can TM168D23AHU101C be shipped?
TM168D23AHU101C is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up TM168D23AHU101C in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for TM168D23AHU101C and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for TM168D23AHU101C, subject to availability and destination.
Schneider Electric TM168D23AHU101C — Base Built - in Display M168 - 23 IO - BMS connectivity (Modicon M168). Discontinued by Schneider Electric. PartnerPLC sources discontinued and surplus Schneider Electric automation parts — request a quote for price, condition and lead time.
Specifications
Main
| Range of product | Modicon M168 logic controller |
| Product or component type | Base controller |
| Product specific application | Air handling unit |
| Variant | Ready to use without PC |
| Communication port protocol | BACnet MS/TP, optional; BACnet IP, optional; Modbus |
| Input/output number | 23 |
| Input/output number | 7 discrete input; 5 configurable analog input; 8 discrete output; 2 configurable analog output |
Complementary
| Discrete input number | 7 |
| Discrete input logic | Sink or source (positive/negative) |
| Discrete input voltage | 24 V |
| Discrete input voltage type | AC/DC |
| Sensor power supply | 4.4…5 V DC; 18…36 V DC |
| Voltage state 1 guaranteed | > 15 V for discrete input |
| Voltage state 0 guaranteed | <= 10 V for discrete input |
| Input impedance | Discrete input: <= 10 kOhm |
| Network frequency | 50...60 Hz +/- 3 Hz discrete input |
| Discrete output number | 5 (8 mA); 3 (5 mA) |
| Contacts type and composition | 7 NO for discrete output; 1 C/O for discrete output |
| Minimum load | 10 mA at 12 V |
| Discrete output current | 8 mA for relay output; 5 mA for relay output |
| Load current | 8 A at 24...250 V AC; 5 A at 5...30 V DC; 5 A at 24...250 V AC; 8 A at 24...250 V DC |
| Mechanical durability | 10000000 cycles for relay output |
| Electrical durability | 120000 cycles DC-12 braking current: 8 A at 30 V, 2 A; 6000 cycles DC-13 braking current: 8 A at 24 V, 2 A 300 ms; 300000 cycles AC-12 braking current: 8 A at 250 V, 2.5 A; 6000 cycles AC-15 braking current: 8 A at 250 V, 3 A, cos phi = 0.3; 120000 cycles DC-12 braking current: 5 A at 30 V, 2 A; 200000 cycles DC-13 braking current: 5 A at 24 V, 1 A 48 ms; 300000 cycles AC-12 braking current: 5 A at 250 V, 2.5 A; 50000 cycles AC-15 braking current: 5 A at 250 V, 3 A, cos phi = 0.4 |
| Operating rate in Hz | 10 Hz - off load for discrete output 8 mA; 0.1 Hz - operating current for discrete output 8 mA; 20 Hz - off load for discrete output 5 mA; 0.1 Hz - operating current for discrete output 5 mA |
| Response time | 10 ms on closing for discrete output 8 mA; 5 ms on opening for discrete output 8 mA; 8 ms on closing for discrete output 5 mA; 4 ms on opening for discrete output 5 mA |
| Analogue input number | 5 |
| Analogue input type | Voltage at 0...10 V or 0...5 V ratio - resolution: 0.01 V; Current at 0...20 mA/4...20 mA - resolution: 0.01 mA; Temperature probe at -50...+120 °C - resolution: 0.1 °C temperature probe: NTC; Temperature probe at -50...+150 °C - resolution: 0.1 °C temperature probe: PTC; Temperature probe at -100...+200 °C - resolution: 0.5 °C temperature probe: Pt 1000 |
| Analogue output number | 2 |
| Analogue output type | Voltage 0...10 V - resolution: 0.01 V; Current 0-20 mA or 4-20 mA - resolution: 0.05 mA |
| Load impedance ohmic | >= 1000 Ohm voltage; 40...300 Ohm current |
| Absolute accuracy error | -5 %...+2 % of full scale 1...5 kOhm for analog output voltage; +/- 2 % of full scale > 5 kOhm for analog output voltage; +/- 3 % of full scale for analog output current; +/- 0.5 % of full scale for analog input |
| LSB value | 10 mV for analog output voltage; 0.02 mA for analog output current; 0.07 °C for analog input NTC; 0.5 °C for analog input Pt 1000; 5 mV for analog input voltage; 0.01 mA for analog input current |
| Communication service | Open collector synchro on AC power supply |
| Protection type | Reverse polarity protection for analog input voltage; Overload protection for analog output voltage; Reverse polarity protection for power supply |
| [Us] rated supply voltage | 20...40 V DC; 24 V AC |
| Supply voltage limits | 20.4…27.6 V |
| Network frequency | 50/60 Hz |
| Network frequency limits | 47…63 Hz |
| Immunity to microbreaks | 10 ms |
| Maximum power consumption in W | 22 W |
| Power consumption in VA | 30 VA at 24 V |
| Memory capacity | 544 kB |
| Realtime clock | With clock, clock drift <= 30 s/month |
| Data backed up | Date and hour internal battery, 3 days autonomy |
| Number of port | 1 Modbus RJ45 slave 1.2...57.6 kbit/s; 1 Modbus RJ45 master/slave 1.2...57.6 kbit/s; 1 expansion bus terminal block master/slave |
| Electrical connection | Analog input (AI1 to AI5, GND, +5 V, 24 V) : 9 1 removable screw terminal block; Discrete input (DI1 to DI7, COM) : 8 1 removable screw terminal block; Fan output (FAN+, FAN-) : 2 1 removable screw terminal block; Expansion bus (+24 V, GND, CAN-, CAN+) : 5 1 removable screw terminal block; Power supply (L/+, N/-) : 2 1 removable screw terminal block; Discrete output (NO1 to NO3, COM 1-2, COM 3) : 5 1 removable screw terminal block; Discrete output (NO4 to NO7, COM 6-7, COM 4-5) : 6 1 removable screw terminal block; Discrete output (NO8, NC8, COM8) : 3 1 removable screw terminal block; Analog output (AO1, AO2, GND) : 3 1 removable screw terminal block |
| Maximum cable distance between devices | 2 twisted pair cables: <1000 m for expansion bus; <30 m for power supply; <100 m for embedded sensor PS; <100 m for analog input; <100 m for relay digital output; <30 m for configurable analog output; <1 m for PWM analog output; <1000 m for SL1 bus; <1000 m for SL2 bus; <100 m for isolated digital input; <100 m for no isolated digital input; USB: <3 m for PC programming tool; TTL: <3 m for PC programming tool; <30 m for supply for remote display |
| Display type | Integrated LCD display |
| Local signalling | 1 LED (green) for PWR; 1 LED (green) for RUN; 1 LED (red) for alarm status; 1 LED (red) for expansion bus; 1 LED (red) for user |
| Mounting support | 35 mm symmetrical DIN rail |
| Width | 251 mm |
| Height | 129.19 mm |
| Depth | 61.5 mm |
| Net weight | 0.79 kg |
Environment
| Standards | EN/IEC 60730-1; EN/IEC 61000-6-1; EN/IEC 61000-6-3 |
| Product certifications | UL 60730-1A; CSA 60730-1 |
| Marking | CE |
| Ambient air temperature for operation | -10…55 °C conforming to UL; -10…60 °C |
| Ambient air temperature for storage | -30…70 °C |
| Relative humidity | 5…95 % without condensation |
| IP degree of protection | IP20; IP40 front face: |
| Pollution degree | 2 |
| Overvoltage category | III |
| Operating altitude | 0...2000 m |
| Storage altitude | 0…3048 m |
| Vibration resistance | 3.5 mm constant amplitude (f = 5…8.4 Hz); 1 gn constant amplitude (f = 8.4…150 Hz) |
| Shock resistance | 15 gn for 11 ms |
Downloads & documentation
Official documents from Schneider Electric, downloaded directly from the manufacturer.
Data sheets & manuals
| Product data sheet TM168D23AHU101C |
More Schneider Electric parts
Available on requestM168 electronic expansion valve driver module stand alone
Available on requestM168 electronic expansion valve driver module with expansion bus port
Available on requestM168 electronic expansion valve driver module w expansion bus and Mod bus port
Available on requestBase Built - in Display M168 - 23 IO - Preprogrammed for Air Handling Units
Available on requestBase Built - in Display M168 - 23 IO - Preprogrammed for Small Chillers
Available on requestBase Built - in Display M168 - 23 IO - BMS connectivity - for Small Chillers
Available on requestBase Built-in Display M168 - 23 IO - Solution - BMS connectivity
Available on requestBase Built-in Display M168 - 23 IO - Solution