Power quality meter, PowerLogic PM8000, Advanced, integrated display, 512 MB, 512 s/c
Power quality meter, PowerLogic PM8000, Advanced, integrated display, 512 MB, 512 s/c, MID certified
"The PowerLogic PM83401 comes in a flush mount form factor with integrated display and is MID approved." "It is designed to help you ensure reliability and efficiency of your power-critical facilitiy." "It unlocks energy transparency and provides actionable data from complex power quality conditions." "With its modular, flexible, and power ION technology, you can build custom applications for each meter." "It comes with revenue grade accuracy, multiple communication ports, and a color graphical display." "This meter also feature onboard power quality analysis as well as a patented Disturbance Direction Detection." "Certified by third party labs for Class 0.2S energy accuracy (IEC62052-11, IEC62053-24, IEC62053-22)." "Certified also for power quality (IEC62586-2, IEC61000-4-30 Class A)." "Cybersecurity features include secure protocols (HTTPs, sFTP, Secure ION), security event logging, Syslog protocol." "Ability to enable/disable communication ports and support 50 configurable user account to help manage access." "With 512MB of memory to support up to 64 data logs (1024 channels), 50+ user-definable alarms, waveform captures upto 512 samples/cycle, 1/2 cycle RMS logging." "The storage can also be used for custom web pages, min/max logs, energy trends, and Time of Use." "The ability to timestamp events to +/-1ms utilizing time synchronization." "Time synch method that include PTP (IEEE1588), NTP, IRIG-B, GPS ASCII (RS485) and network time set function." "3 digital inputs and one digital output, plus the ability to add up to 4 option modules." "I/O option modules include 2 relays and 6 digital inputs or 2 analog outputs and 4 analog inputs" "Wide control power range of 90-415 VAC / 110-415 VDC." "Operating environment of -25 to +70°C; Humidity rating of 5% to 95%; Altitude up to 3000 m."
| Range | PowerLogic |
| Product name | PowerLogic PM8000 |
| Product or component type | Power meter |
| Device short name | PM8340 |
| Market segment | Buildings large building cost management: billing: sub feeder, Buildings small building network management: main incomer, Buildings medium building network management: main incomer, Buildings large building network management: main incomer, Buildings large building network management: billing: sub feeder, Buildings multi-site network management: main incomer, Buildings multi-site network management: sub feeder, Data center network management: main incomer, Data center large building network management: sub feeder, Healthcare multi-site network management: main incomer, Healthcare network management: sub feeder, Industry network management: main incomer, Industry network management: sub feeder, Utility: sub feeder |
| model type | Advanced |
| Power quality analysis | Conforming to EN 50160: 2010 compliance report, conforming to IEEE 519: 2014 compliance report, conforming to IEC 61000-4-30: class A power quality measurement, conforming to IEC 61000-4-30: class A up to the 63rd harmonic, harmonic distortion, conforming to EN 50160: 2010 waveform capture, voltage sag and swell detection, programmablity (logic and math functions), conforming to IEC 62586 power quality monitoring, disturbance direction detection, conforming to IEC 61000-4-15 flicker, rapid voltage change |
| Device application | WAGES metering, Power monitoring |
| Type of measurement | Current, Voltage total, Frequency total, Active and reactive power total, Apparent power total, Power factor total, Active and reactive power per phase, rms, Apparent power per phase, rms, Power factor per phase, rms |
| supply voltage | 90...415 V AC 45...65 Hz +/- 10 %, 110...415 V DC +/- 10 % |
| Network frequency | 50 Hz, 60 Hz |
| [In] rated current | 1 A, 10 A, 5 A |
| Poles description | 3P + N, 1P + N, 3P |
| Power consumption in VA | 16 VA at 230 V AC |
| Display type | Colour TFT LCD |
| Display resolution | 320 x 240 pixels QVGA |
| Sampling rate | 512 samples/cycle |
| Measurement current | 50…10000 mA |
| Analogue input type | Voltage (impedance 5 MOhm), Current (impedance 0.3 mOhm) |
| Measurement voltage | 57…400 V AC 42...69 Hz between phase and neutral, 100…690 V AC 42...69 Hz between phases |
| Frequency measurement range | 42…69 Hz |
| Number of inputs | 3 digital 30 V AC, 3 digital 60 V DC |
| Measurement accuracy | Current +/- 0.1 %, Voltage +/- 0.1 %, Active energy +/- 0.2 % |
| Accuracy class | Class 0.2S active energy conforming to IEC 62053-22, Class 0.2 active energy conforming to ANSI C12.20, Class 0.2 active power conforming to IEC 61557-12, Class 0.5S reactive energy conforming to IEC 62053-24, Class 0.5 power factor conforming to IEC 61557-12, Class 0.2 voltage conforming to IEC 61557-12, Class 0.2 current conforming to IEC 61557-12 |
| Number of outputs | 1 pulse |
| Information displayed | Voltage, Current, Frequency, Power, Energy consumption, Harmonic distortion |
| Communication port protocol | Modbus RTU at 115 kbauds - 2-wire, ION at 115 kbauds - 2-wire, DNP3, IEC 61850, Modbus TCP/IP, Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s, RSTP 801.1d 2004 |
| Communication port support | ETHERNET, Screw terminal block: RS485 |
| Data recording | Time stamping, Sequence of event recording, GPS synchronisation, Min/max of instantaneous values, Event logs, Sag and swell logs, Harmonics logs, Trending/forecasting, Data logs, Alarm logs, Waveform logs, 64 data recorders |
| Memory capacity | 512 MB |
| Web services | Customizable home page, File upload/download via FTP, File upload/download via SFTP, Web server, Alarm notification by e-mail, Viewing of captured waveform (FTP), Viewing of captured waveform (web), HTTPS server |
| Communication service | RSTP support, SMTP e-mail notification, NTP time synchronization, SNMP, PTP time synchronization |
| Mounting mode | Flush-mounted |
| Mounting support | Framework |
| Installation category | III |
| Safety Construction | III400…690 V conforming to IEC 61010-1:ed. 3, III400…690 V conforming to EN 61010-1:ed. 3, III347…600 V conforming to UL 61010-1:ed. 3, III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3 |
| Standards | IEC 61557-12, IEC 62052-11, IEC 62053-22, IEC 62053-24, IEEE 1588, IEC 62586-2, IEC 61326-1 |
| Product certifications | CE, CULus, N998, MID |
| Width | 96 mm |
| Depth | 77.5 mm |
| Height | 96 mm |
| Net weight | 581 g |
| Targeted country | United Kingdom |
| Electromagnetic compatibility | Electrostatic discharge conforming to IEC 61000-4-2, Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3, Electrical fast transient/burst immunity test conforming to IEC 61000-4-4, Surge immunity test conforming to IEC 61000-4-5, Conducted RF disturbances conforming to IEC 61000-4-6, Magnetic field at power frequency conforming to IEC 61000-4-8, Voltage dips and interruptions immunity test conforming to IEC 61000-4-11, Immunity to impulse waves conforming to IEC 61000-4-12, Conducted and radiated emissions conforming to EN 55022, Conducted and radiated emissions conforming to EN 55011, Conducted and radiated emissions conforming to FCC part 15, Conducted and radiated emissions conforming to ICES-003, Conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579, Surge withstand (2...150 Hz) conforming to IEEE C37.90.1 |
| IP degree of protection | IP54 front: conforming to IEC 60529, IP30 body: conforming to IEC 60529 |
| Relative humidity | 5…95 % |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Operating altitude | 3000 m |
| Package 1 | 1 PCE, 18.800 cm × 14.300 cm × 13.800 cm (L × W × H), 900.000 g |
| Package 2 | 8 S03, 40.000 cm × 30.000 cm × 30.000 cm (L × W × H), 8.073 kg |
Official documents from Schneider Electric, downloaded directly from the manufacturer.
METSEPM83401 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Yes — mention it when you request a quote for METSEPM83401 and we'll include express shipping options in our reply.
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for METSEPM83401, subject to availability and destination.

Power quality meter, PowerLogic PM8000, Advanced, integrated display, 512 MB, 512 s/c

Power quality meter, PowerLogic PM8000, Advanced, transducer, 512 MB, 512 s/c

Power quality meter, PowerLogic PM8000, transducer and remote display, 512 MB, 512 s/c

Power quality meter, PowerLogic PM8000, Advanced, integrated display, 512 MB, 512 s/c

Power quality meter, PowerLogic PM8000, Advanced, transducer, 512 MB, 512 s/c

Power quality meter, PowerLogic PM8000, Advanced, transducer and remote display, 512 MB, 512 s/c


PowerLogic PM8000 - I/O Module - Digital - 6 Inputs + 2 relays outputs