Controller, Harmony SCU, Rear Module panel, Dig 16 inputs/10 outputs
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Harmony SCU |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.36 kg |
Shipping & availability
When can HMISAC be shipped?
HMISAC is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up HMISAC in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for HMISAC and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for HMISAC, subject to availability and destination.
This rear module controller offers 16 digital inputs and 10 outputs. It is a controller with a supply voltage of 24V DC. It features CPU RISC processor, 128MB flash NAND, 128kB FRAM internal data storage and 128MB application run DRAM. It is an equipped with 1 serial link, 1 Ethernet TCP/IP - RJ45, 1 USB 2.0 type mini B, 1 USB 2.0 type A and DE-09 D-sub CANopen master bus connections. It is an IP20 (rear panel) conforming to IEC 60529, IP65 (front panel) conforming to IEC 60529 and NEMA 4X front panel rated product. The enclosure is made of PC/PBT. Its dimensions are 128mm (width) x 102mm (depth) x 50.65mm (height). It weighs 0.359kg. This product is certified by GOST, C-Tick, KCC and CULus. It meets ANSI/ISA 12-12-01, UL 508, IEC 61000-6-2 and CSA C22.2 No 213 Class I Division 2 standards. It can be installed into 1mm to 6mm thick panel. The integrated design of Harmony SCU delivers maximum functionality while keeping installation easy. The Harmony SCU (formerly known as Magelis SCU) is designed to operate with the EcoStruxure Machine Expert, delivers adequate functionality for control of small machines.
Specifications
Specifications
| Range of product | Harmony SCU |
| Product or component type | Controller |
| Device presentation | Basic element |
| Supply | External source |
| [Us] rated supply voltage | 24 V (20.4…28.8 V)DC |
| Immunity to microbreaks | 10 ms |
| Inrush current | 30 A |
| Power consumption in W | 15 W |
| Local signalling | No indicator |
| Number of pages | Limited by internal memory capacity |
| Operating system | Harmony |
| Processor name | CPU RISC |
| Memory description | Flash NAND, 128 MB, Internal data storage FRAM, 128 kB, Application run DRAM, 128 MB |
| Integrated connection type | 1 serial link - RJ45 - RS232/RS485 (rate: <= 115.2 kbits/s), 1 Ethernet TCP/IP - RJ45, 1 USB 2.0 type mini B, 1 USB 2.0 type A, CANopen master bus - SUB-D 9 |
| Realtime clock | Built-in |
| Downloadable protocols | Modbus, Modbus TCP/IP, CANopen |
| Fixing mode | By 1 nut - diameter: Ø 22 mm, mounting on: 1...6 mm thick panel |
| Enclosure material | PC/PBT |
| Shock resistance | 147 m/s² for 11 ms (on DIN rail) conforming to IEC 60068-2-27, 294 m/s² for 6 ms (on panel mounting) conforming to IEC 60068-2-27 |
| Vibration resistance | +/- 3.5 mm (f = 5…9 Hz) conforming to IEC 60068-2-6, 1 gn (f = 9…150 Hz) conforming to IEC 60068-2-6 |
| Electromagnetic compatibility | Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2, Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2, Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz...3 GHz) conforming to IEC 61000-4-3, Electrical fast transient/burst immunity test - test level: 2 kV (power lines) conforming to IEC 61000-4-4, Electrical fast transient/burst immunity test - test level: 1 kV (between analogue I/O and operating voltage) conforming to IEC 61000-4-4, Electrical fast transient/burst immunity test - test level: 2 kV (relay wires) conforming to IEC 61000-4-4, Electrical fast transient/burst immunity test - test level: 1 kV (Ethernet line) conforming to IEC 61000-4-4, Electrical fast transient/burst immunity test - test level: 1 kV (COM line) conforming to IEC 61000-4-4, Electrical fast transient/burst immunity test - test level: 1 kV (CAN line) conforming to IEC 61000-4-4, Surge immunity test - test level: 2 kV (power supply (common mode)) conforming to IEC 61000-4-5, Surge immunity test - test level: 1 kV (power supply (differential mode)) conforming to IEC 61000-4-5, Surge immunity test - test level: 1 kV common mode (digital I/O) conforming to IEC 61000-4-5, Surge immunity test - test level: 0.5 kV differential mode (digital I/O) conforming to IEC 61000-4-5, Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6, Conducted emission - test level: 150 kHz...30 MHz conforming to EN 55011, Radiated emission - test level: 30 MHz...1 GHz conforming to EN 55011 |
| Discrete input number | 2 for fast input (normal mode) conforming to IEC 61131-2 Type 1, 14 for digital input conforming to IEC 61131-2 Type 1 |
| Discrete input voltage | 24 V DC, discrete input logic: sink or source (positive/negative) |
| Number of common point | 1 for fast input (HSC mode), 2 for digital input |
| Discrete input current | 7.83 mA for fast input, 5 mA for digital |
| Input impedance | 4.7 kOhm, 2.81 kOhm |
| Sensor power supply | 15…28.8 V DC >= 15 V, current (state 1): >= 5 mA <= 5 V, current (state 0): <= 1.5 mA, 15…28.8 V DC >= 15 V, current (state 1): >= 2.5 mA <= 5 V, current (state 0): <= 1 mA |
| Configurable filtering time | 0 ms no filter (none), 0.004...0.04 ms bounce filter (latch/event and cumulative filter by step Nx0.5ms (64>=N>=2)), 3...12 ms integrator (none/run/stop) |
| Maximum input frequency | 100 kHz for fast input (encoder mode) - control type A/B, 100 kHz for fast input - control type single phase, 100 kHz for fast input - control type pulse/direction |
| Maximum cable distance between devices | Shielded cable: <10 m for fast input, Shielded cable: <100 m for digital input, Unshielded cable: <50 m for digital input |
| Connection pitch | 3.5 mm |
| Overvoltage protection | With overvoltage protection |
| Isolation between channels and internal logic | 500 V DC |
| Isolation between channels | None |
| Discrete output number | 2 fast output (normal mode), output logic: source, 8 digital output, output logic: source |
| Discrete output voltage | 24 V DC (voltage limit: 19.2...28.8 V) with transistor discrete output(s), 24 V DC (voltage limit: 5...30 V) with relay discrete output(s), 220 V AC (voltage limit: 100...250 V) with relay discrete output(s) |
| Input/output number | 2 for fast input, terminal(s): FI0...FI1, 14 for digital input, terminal(s): DI0...DI13, 2 for fast output, terminal(s): FQ0...FQ1, 8 for digital output, terminal(s): DQ0...DQ7 |
| Discrete output current | 2 A 4 A), response time 5 ms with opening contact for digital output, 2 A 4 A), response time 2 ms with closing contact for digital output, 300 mA, response time 2 ms for fast output (normal mode), 50 mA, response time 2 ms for fast output (PWM or PTO mode) |
| Insulation resistance | > 10 MOhm between the I/O and internal logic, > 10 MOhm between power supply and earth |
| Maximum output frequency | 100 kHz for fast output (PTO mode), 1 kHz for fast output (PWM mode) |
| Absolute accuracy error | +/- 0.1 % of full scale cyclic ratio 1...99% for fast output (PWM or PTO mode), 1 % of full scale cyclic ratio 1...99% for fast output (PWM or PTO mode), +/- 5 % of full scale cyclic ratio 10...90% for fast output (PWM or PTO mode), +/- 10 % of full scale cyclic ratio 20...80% for fast output (PWM or PTO mode), +/- 15 % of full scale cyclic ratio 30...70% for fast output (PWM or PTO mode) |
| Height | 50.65 mm |
| Width | 128 mm |
| Depth | 102 mm |
| Net weight | 0.359 kg |
| Standards | FCC Class A, ANSI/ISA 12-12-01, UL 508, IEC 61000-6-2, EN 61131-2, CSA C22.2 No 213 Class I Division 2 |
| Product certifications | GOST, C-Tick, KCC, cULus 508, cULus CSA 22-2 No 142, cUL 1604 Class 1 Division 2 |
| Marking | CE |
| Ambient air temperature for operation | 0…50 °C |
| Ambient air temperature for storage | -20…60 °C |
| Relative humidity | 5…85 % without condensation |
| Operating altitude | <= 2000 m |
| Storage altitude | 0…10000 m |
| Maximum pressure | 800...1114 hPa |
| IP degree of protection | IP20 (rear panel) conforming to IEC 60529, IP65 (front panel) conforming to IEC 60529 |
| NEMA degree of protection | NEMA 4X front panel |
| Pollution degree | 2 conforming to IEC 60664 |
| Environmental characteristic | Corrosive gas free |
| Unit Type of Package 1 | PCE |
| Number of Units in Package 1 | 1 |
| Package 1 Height | 9.200 cm |
| Package 1 Width | 19.000 cm |
| Package 1 Length | 26.800 cm |
| Package 1 Weight | 988.000 g |
| Unit Type of Package 2 | S03 |
| Number of Units in Package 2 | 6 |
| Package 2 Height | 30.000 cm |
| Package 2 Width | 30.000 cm |
| Package 2 Length | 40.000 cm |
| Package 2 Weight | 6.677 kg |
| Warranty (in months) | 18 |