Schneider Electric ATV61EXS5C40N4 – enclosed variable speed drive ATV61 Plus - 400 kW - 400V - IP54 SA
Discontinued by Schneider Electric — we can still source the original ATV61EXS5C40N4 (new, used or refurbished, subject to availability). Request a quote below.
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Altivar 61 Plus |
| Lifecycle | Discontinued |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Country of origin | FR |
| UPC / EAN | 3389118321144 |
| Recommended replacement | ATV660C40Q4X1 |
| Datasheet | Manufacturer datasheet ↗ |
Shipping & availability
Can I still buy the ATV61EXS5C40N4 now that it is discontinued?
Yes. Schneider Electric has discontinued the ATV61EXS5C40N4, but sourcing discontinued parts is what PartnerPLC specialises in — new old stock, used and refurbished units. Request a quote and we'll confirm availability, condition and lead time. If you are planning an upgrade instead, Schneider Electric names the ATV660C40Q4X1 as its successor — we can quote both.
When can ATV61EXS5C40N4 be shipped?
ATV61EXS5C40N4 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up ATV61EXS5C40N4 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for ATV61EXS5C40N4 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for ATV61EXS5C40N4, subject to availability and destination.
Schneider Electric ATV61EXS5C40N4 — enclosed variable speed drive ATV61 Plus - 400 kW - 400V - IP54 SA (Altivar 61 Plus). Discontinued by Schneider Electric; the manufacturer's successor is ATV660C40Q4X1. PartnerPLC sources discontinued and surplus Schneider Electric automation parts — request a quote for price, condition and lead time.
Specifications
Main
| Range of product | Altivar 61 Plus |
| Product or component type | Variable speed drive |
| Device short name | ATV61 |
| Product destination | Synchronous motors; Asynchronous motors |
| Product specific application | Pumping and ventilation machine |
| Assembly style | In floor-standing enclosure with separate air flows |
| product composition | A switch and fast-acting fuses; A DC choke; A plinth; An IP65 remote mounting kit for graphic display terminal; ATV61HC40N4 standard drive IP00; A wired ready-assembled Sarel Spacial 6000 enclosure; Terminals/bars for motor connection |
| EMC filter | Integrated |
| Network number of phases | 3 phases |
| rated supply voltage | 380...415 V +/- 10 % |
| Supply frequency | 50...60 Hz |
| Motor power kW | 400 kW, 3 phases at 380...415 V |
| Line current | 661 A at 400 V3 phases / 400 kW |
| IP degree of protection | IP54 |
Complementary
| Apparent power | 467 kVA for 400 V, 3 phases 400 kW |
| Prospective line Isc | 50 kA with external fuses |
| Continuous output current | 759 A, 2.5 kHz at 400 V 3 phases |
| Maximum transient current | 911 A for 60 s, 3 phases |
| Speed drive output frequency | 0.1…500 Hz |
| Nominal switching frequency | 2.5 kHz |
| Switching frequency | 2...8 kHz adjustable; 2.5...8 kHz with derating factor |
| Speed range | 1…100 in open-loop mode, without speed feedback |
| Speed accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn without speed feedback |
| Torque accuracy | +/- 15 % in open-loop mode, without speed feedback |
| Transient overtorque | 120 % of nominal motor torque for 60 s; 135 % of nominal motor torque for 2 s |
| Braking torque | 30 % without braking resistor; <= 125 % with braking resistor |
| Asynchronous motor control profile | Flux vector control without sensor, standard; Voltage/frequency ratio, 2 points; Voltage/frequency ratio, 5 points; Voltage/frequency ratio - Energy Saving, quadratic U/f |
| Synchronous motor control profile | Vector control without sensor, standard |
| Regulation loop | Adjustable PI regulator |
| Motor slip compensation | Automatic whatever the load; Not available in voltage/frequency ratio (2 or 5 points); Adjustable; Suppressable |
| Supply voltage limits | 342…457 V |
| Network frequency limits | 47.5…63 Hz |
| Overvoltage category | Class 3 conforming to EN 50178 |
| Local signalling | LCD display unit for operation function, status and configuration - mounted in the front door |
| Output voltage | <= supply voltage |
| Isolation | Electrical between power and control |
| type of cable for external connection | IEC cable at 40 °C, copper 70 °C / PVC |
| Electrical connection | Terminal - 2.5 mm² / 14 AWG (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR) entry from the bottom; Bar M12 - 4 x 300 mm² (L1/R, L2/S, L3/T) entry from the bottom; Bar M12 - 4 x 240 mm² (U/T1, V/T2, W/T3) entry from the bottom |
| Motor recommanded cable cross section | 3 (3 x 185) mm² |
| Short-circuit protection | 1000 A fuse protection type gI - power supply upstream |
| Supply | External supply: 24 V (19…30 V)DC, <1 A; Internal supply for reference potentiometer: 10 V (10…11 V)DC, <10 mA; Internal supply: 24 V (21…27 V)DC, <100 mA |
| Analogue input number | 2 |
| Analogue input type | AI2 software-configurable voltage: 0...10 V DC, 24 V max, impedance: 30 kOhm, sampling time: 1.5…2.5 ms, resolution: 11 bits; AI1-/Al1+ bipolar differential voltage: +/- 10 V DC, 24 V max, sampling time: 1.5…2.5 ms, resolution: 11 bits + sign; AI2 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, sampling time: 1.5…2.5 ms, resolution: 11 bits |
| Analogue output number | 1 |
| Analogue output type | Software-configurable voltage: (AO1) 0...10 V DC - 470 Ohm - sampling time: 1.5…2.5 ms - resolution: 10 bits; Software-configurable current: (AO1) 0...20 mA/4...20 mA - 500 Ohm - sampling time: 1.5…2.5 ms - resolution: 10 bits |
| Discrete output number | 2 |
| Discrete output type | Configurable relay logic: (R2A, R2B)NO - 6.5...7.5 ms - 100000 cycles; Configurable relay logic: (R1A, R1B, R1C)NO/NC - 6.5...7.5 ms - 100000 cycles |
| Minimum switching current | 3 mA at 24 V DC (configurable relay logic) |
| Maximum switching current | 5 A at 250 V AC on resistive load - cos phi = 1 for configurable relay logic; 2 A at 30 V DC on inductive load - L/R = 7 ms for configurable relay logic; 5 A at 30 V DC on resistive load - L/R = 0 ms for configurable relay logic; 2 A at 250 V AC on inductive load - cos phi = 0.4 for configurable relay logic |
| Discrete input number | 7 |
| Discrete input type | Programmable (LI1...LI5) at 24 V DC <= 30 V level 1 PLC 3.5 kOhm (duration=1.5…2.5 ms); Switch-configurable (LI6) at 24 V DC <= 30 V level 1 PLC 1.5 kOhm (duration=1.5…2.5 ms); Safety input (PWR) at 24 V DC <= 30 V 1.5 kOhm |
| Discrete input logic | Positive logic (source) (LI1...LI6), 0...5 V (state 0), 11...30 V (state 1); Negative logic (sink) (LI1...LI6), 16...30 V (state 0), 0...10 V (state 1); Positive logic (source) (PWR), 0...2 V (state 0), 17...30 V (state 1) |
| Acceleration and deceleration ramps | S, U or customized; Linear adjustable separately from 0.01 to 9000 s |
| Braking to standstill | By DC injection, <60 s |
| Protection type | Against exceeding limit speed: drive; Against input phase loss: drive; Break on the control circuit: drive; Input phase breaks: drive; Line supply overvoltage: drive; Line supply undervoltage: drive; Overcurrent between output phases and earth: drive; Overheating protection: drive; Overvoltages on the DC bus: drive; Power removal: drive; Short-circuit between motor phases: drive; Thermal protection: drive; Motor phase break: motor; Power removal: motor; Thermal protection: motor |
| Dielectric strength | 3535 V DC between earth and power terminals; 5092 V DC between control and power terminals |
| Insulation resistance | > 1 mOhm 500 V DC for 1 minute |
| Frequency resolution | Analog input: 0.024/50 Hz; Display unit: 0.1 Hz |
| Communication port protocol | Modbus; CANopen |
| Connector type | 1 RJ45 (on front face) for Modbus; 1 RJ45 (on terminal) for Modbus; Male SUB-D 9 on RJ45 for CANopen |
| Physical interface | 2-wire RS 485 for Modbus |
| Transmission frame | RTU for Modbus |
| Transmission rate | 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal; 9600 bps, 19200 bps for Modbus on front face; 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen |
| Data format | 8 bits, 1 stop, even parity for Modbus on front face; 8 bits, odd even or no configurable parity for Modbus on terminal |
| Type of polarization | No impedance for Modbus |
| Number of addresses | 1…127 for CANopen; 1…247 for Modbus |
| Method of access | Slave CANopen |
| options for enclosure configuration | Safe standstill for power circuit; PTC relay for power circuit; Pt100 relay for power circuit; Insulation monitoring for power circuit; Design for IT networks for power circuit; External 230 V supply terminals for power circuit; Buffer voltage 24 V DC power supply for power circuit; Enclosure lighting for power circuit; Key switch (local/remote) for power circuit; Motor heating for power circuit; External motor fan for power circuit; Voltmeter for power circuit; Door handle for main switch for power circuit; Line contactor for power circuit; Ammeter for power circuit; Enclosure heating for power circuit; Motor choke for power circuit; Cable entry via the top for power circuit; Braking unit for power circuit; Relay output C/O for control circuit; External 24 V DC supply terminals for power circuit; Control terminals for control circuit; Adaptor for 115 V logic inputs for control circuit; Isolated amplifier for control circuit; Circuit breaker for control circuit; Enclosure plinth for control circuit |
| Option card | Communication card for APOGEE FLN; Communication card for BACnet; Communication card for CC-Link; Communication card for DeviceNet; Communication card for EtherNet/IP; Communication card for Fipio; Communication card for Interbus-S; Communication card for LonWorks; Communication card for METASYS N2; Communication card for Modbus Plus; Communication card for Modbus TCP; Communication card for Modbus/Uni-Telway; Communication card for Profibus DP; Communication card for Profibus DP V1; Controller inside programmable card; Multi-pump card; Basic I/O extension card; Extended I/O extension card; Encoder interface cards |
| Operating position | Vertical +/- 10 degree |
| Colour of enclosure | Light grey (RAL 7035) |
| Colour of base of enclosure | Dark grey (RAL 7022) |
| Width | 1400 mm |
| Height | 2362 mm |
| Depth | 642 mm |
| Net weight | 745 kg |
Environment
| Electromagnetic compatibility | 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5; Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6; Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4; Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2; Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3; Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
| Standards | EN/IEC 61800-5-1; EN 61800-3 environments 1 category C3; EN/IEC 61800-3; EN 55011 class A group 2; EN 61800-3 environments 2 category C3 |
| Product certifications | ATEX; GOST |
| Marking | CE |
| Noise level | 73 dB |
| Pollution degree | 3 conforming to EN/IEC 61800-5-1 |
| Vibration resistance | 0.6 gn (f= 10…200 Hz) conforming to EN/IEC 60068-2-6; 1.5 mm (f= 3…10 Hz) conforming to EN/IEC 60068-2-6; 3M3 conforming to EN/IEC 60721-3-3 |
| Shock resistance | 4 gn for 11 ms conforming to EN/IEC 60068-2-27; 3M2 conforming to EN/IEC 60721-3-3 |
| Environmental characteristic | 3C2 without condensation conforming to IEC 60721-3-3; 3S2 without condensation conforming to IEC 60721-3-3; 3K3 without condensation conforming to IEC 60721-3-3 |
| Relative humidity | 0…95 % |
| Ambient air temperature for operation | 0…40 °C (without derating); 40…50 °C (with current derating of 1.8 % per °C) |
| Ambient air temperature for storage | -25…70 °C |
| Volume of cooling air | 2200 m3/h |
| Operating altitude | <= 1000 m without derating; 1000...3000 m with current derating 1 % per 100 m |
Downloads & documentation
Official documents from Schneider Electric, downloaded directly from the manufacturer.
Data sheets & manuals
| Product data sheet ATV61EXS5C40N4 |
More Schneider Electric parts
Available on requestenclosed variable speed drive ATV61 Plus - 310 kW - 500V - IP54 SA
Available on requestenclosed variable speed drive ATV61 Plus - 310 kW - 400V - IP54 SA
Available on requestenclosed variable speed drive ATV61 Plus - 310 kW - 690V - IP54 SA
Available on requestenclosed variable speed drive ATV61 Plus - 400 kW - 500V - IP54 SA
Available on requestenclosed variable speed drive ATV61 Plus - 500 kW - 500V - IP54 SA
Available on requestenclosed variable speed drive ATV61 Plus - 500 kW - 400V - IP54 SA
Available on requestenclosed variable speed drive ATV61 Plus - 500 kW - 690V - IP54 SA
Available on requestenclosed variable speed drive ATV61 Plus - 630 kW - 500V - IP54 SA