Pilz 327500 – PSS u2 ES 4AI U -R
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | PSSuniversal 2 - Standard I/O modules |
| Lifecycle | Active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
| Weight | 0.037 kg |
| UPC / EAN | 4046548103489 |
Shipping & availability
When can 327500 be shipped?
327500 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up 327500 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for 327500 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for 327500, subject to availability and destination.
PSS u2, electronic module for standard applications, 4 analogue inputs, for increased environmental requirements and railway applications,terminal block PSS u2 T 16 required (not supplied with the system)
Specifications
General data
| Product ID (Pilz order number) | 327500 |
| Approval | CE, UKCA, cULus Listed |
| Application range | Standard |
| Lifecycle | Active (current Pilz product) |
Analog inputs
| Number of analogue inputs | 4 |
| Type of analogue inputs | Spannung |
| Analog input signal type 1 | Differenzeingang |
| Analog input Signal range 1 | -12,8 V - +12,8 V |
| Analog input signal type 2 | Differenzeingang |
| Analog input Signal range 2 | -6,4 V - +6,4 V |
| Analog input signal type 3 | Differenzeingang |
| Analog input Signal range 3 | -3,2 V - +3,2 V |
| Type of input filter | RC-Filter, 1. Ordnung |
| Value least signif. bit U-Me | 97,65625 µV (-3,2 V - +3,2 V), 195,3125 µV (-6,4 V - +6,4 V), 390,625 µV (-12,8 V - +12,8 V) |
| Resolution of analogue inputs | 16 |
| Monotony without error codes | Ja |
| Conversion method analog i/p | sukzessive Approximation |
| Max.processing.time analog i/p | tEingangs- & tSW-Filter+0,1 ms |
| Potential isol. Analogue input | ja |
Environmental data
| App. site standard1 railway | EN 50125-3 |
| App. site to standard1 railway | Abstand mind. 1m vom Gleis |
| Climatic suitability to ... | EN 60068-2-30, EN 60068-2-2, EN 60068-2-1, EN IEC 60068-2-14, EN 60068-2-78 |
| Ambient temperature | -40 °C |
| UL spec. ambient temperature | UL 61010 |
| Ambient temp. with UL | -40 - 60 °C |
| Climatic suitability standard | EN 60068-2-78 |
| Humidity rating | 95 % r. F. bei 40 °C |
| Condensation permitted? | EN 60068-2-30 |
| Perm. operating height ASL | 5000 m |
| EMC to standard ... | EN 12015, EN IEC 61000-6-2, EN 12016, EN 50121-4, EN 298, EN 61000-6-7, EN IEC 61000-6-4, EN 61131-2 (Zone B), EN 50156-1 |
| Vibration to standard ... | EN 60068-2-6 |
| Broad band noise to | EN 60068-2-64 |
| Acc. shock to standard1 | 150 m/s² |
| Acc. shock to standard2 | 100 m/s² |
| Clearance & creepage dist.to 2 | EN 81-20, EN 50156-1 |
| Overvoltage category 2 | III |
| Clearance & creepage dist. to | EN 61131-2 |
| Overvoltage category | II |
| Pollution degree clear.&creep. | 2 |
| Protection type standard | EN 60529 |
| Protection type, housing | IP20 |
| Terminal protection type | IP20 |
Potential separation
| Potential isolation 1 between | Anal. Eing. und Module Supply |
| Type of potential isolation 1 | Funktionsisolierung |
| Potential isolation 2 between | Anal. Eing. und Periph. Supply |
| Type of potential isolation 2 | Funktionsisolierung |
| Potential isolation 3 between | Analoger Eingang und P0 |
| Type of potential isolation 3 | Funktionsisolierung |
| Potential isolation 4 between | Periphery und Module Supply |
| Type of potential isolation 4 | Funktionsisolierung |
Mechanical data
| Housing material | PC |
| Terminal style | steckbar |
| Height dimension | 110.8 mm |
| Width dimension | 12.5 mm |
| Depth dimension | 72.5 mm |
| Net weight | 37 g |
| Gross weight | 53 g |
Environment
| WEEE classification (08/2018) | 5 devices (feed size < 50cm) |
Commercial data
| ECLASS version | ECLASS-13 |
| ECLASS Reference Feature | 27242604 |
| ETIM Version | ETIM-9.0 |
| ETIM Reference Group | EG000024 |
| ETIM Reference Feature | EC001599 |
| UNSPSC 25 | 39122331 |
| GTIN | 4046548103489 |
| Volume | 0.27 dm3 |
| Harmonized System Code | 85389091 |
Downloads & documentation
Official documents from Pilz, downloaded directly from the manufacturer.
Data sheets & manuals
| 3rd-party lic. PSS u2 ES 4AI U/I (-R) | PDF · 1.2 MB |
| Inst. Man. PSS u2 in PSS 4000 | PDF · 17.2 MB |
| Operat.Manual PSS u2 ES 4AI U | PDF · 3.3 MB |
| Operat.Manual PSS u2 ES 4AI U | PDF · 3.3 MB |
CAD & dimension drawings
Certificates (3)
| Certificate (TÜV) Z10-020132-0306-R02 | PDF · 2.9 MB |
| EU/EC-Declaration of Conformity (Konformitätserklärung) | PDF · 0.2 MB |
| UK Declaration of Conformity (UKCA) | PDF · 0.2 MB |