Pepperl Fuchs VBA-4E4A-KE5-ZEJQ/R
AS-Interface sensor/actuator module
- MPN
- VBA-4E4A-KE5-ZEJQ/R
- Category
- Modules
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Pepperl Fuchs VBA-4E4A-KE5-ZEJQ/R?
Housing with push-in connection technology and mechanically coded terminal blocks
Housing width 19 mm, installation in the switch cabinet on DIN mounting rail
Selectable supply to the sensors: External or from the module
Function display for bus, internal sensor supply, inputs, and outputs
Cabinet module, 4 inputs and 4 relay outputs
Specifications
General specifications
| Order code (Pepperl+Fuchs part number) | 263814 |
| Node type | A/B node |
| AS-Interface specification | V3.0 |
| Required gateway specification | ≥ V3.0 |
| UL File Number | E223772 |
| MTBF | 224 a |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Indicators/operating means
| LED FAULT | Fault display; Red LED red: Communication fault or address is 0 red, flashing: Overload, internal input supply |
| LED INT | Internal input supply active; LED green |
| LED PWR | AS-Interface voltage; green LED green: voltage OK flashing green: address 0 |
| LED IN | switching state (input); 4 LED yellow |
| LED OUT | Switching state (output); 4 LED yellow |
Electrical specifications
| Auxiliary voltage (input) | 12 ... 30 V DC PELV UEXT |
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface Ue |
| Rated operating current | ≤ 35 mA (without sensors) / max. 230 mA Ie |
| Surge protection | O1 ... O4: Over voltage category IIUEXT, Ue: overvoltage category II, safe isolated power supplies (PELV) |
Input
| Number/Type | 4 inputs for 3-wire sensors (PNP), DC |
| Supply | from AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT) |
| Voltage | 21 ... 31 V DC (INT) |
| Current loading capacity | ≤ 150 mA, overload- and short-circuit protected (INT) |
| Input current | ≤ 5.6 mA (max.) |
| Switching point | according to DIN EN 61131-2 (type 1) |
| 0 (unattenuated) | ≤ 0.5 mA |
| 1 (attenuated) | ≥ 2 mA |
| Signal delay | < 1 ms (input/AS-Interface) |
Output
| Number/Type | 4 relay outputs, normally open |
| Supply | none |
| Nominal load: Per contact | 2 A/30 VDC; 2 A/250 VAC For more information, see the "Galvanic Isolation" section |
| Nominal load: Per module | 8 A |
| Control circuit | ≤ 11 mA per relay (from AS-Interface) |
| Switching delay | < 10 ms (AS-Interface/contact) |
| Usage category | DC-13 and AC-14 |
| Switching: Mechanical | 5 x 107 |
| Switching: Electrical | 2 x 105 (250 VAC, 2 A, cos φ = 0.4) |
| Overload protection | fuse unit 2 A required in the load current circuit |
Galvanic isolation
| Input/Output | safe isolation, Rated insulation voltage 252 Veff |
| Input/AS-Interface | Switch position INT: None Switch setting EXT: safe isolation, rated insulation voltage 92 Veff |
| Output/Output | Basic insulation, rated insulation voltage 250 Veff, in phase |
| Output/AS-Interface | safe isolation, Rated insulation voltage 252 Veff |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007 |
| Low voltage: Directive 2006/95/EC | EN 60664-1:2007 |
Standard conformity
| Galvanic isolation | EN 60664-1:2007 |
| Degree of protection | EN 60529:2000 |
| Fieldbus standard | EN 62026-2:2013 |
| Electrical safety | IEC 61140:2009 |
| Input | EN 61131-2:2004 |
| Emitted interference | EN 61000-6-4:2007 |
| AS-Interface | EN 62026-2:2013 |
| Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 |
Programming instructions
| Profile | S-7.A.7 |
| IO code | 7 |
| ID code | A |
| ID1 code | 7 |
| ID2 code | 7 |
| Data bits (function via AS-Interface) | InputOutput |
| D0 | IN1 O1 |
| D1 | IN2 O2 |
| D2 | IN3 O3 |
| D3 | IN4 O4 |
| Parameter bits (programmable via AS-i) | function |
| P0 | Communication monitoring P0 = 0 monitoring = off, the outputs maintain the status if communication fails P0 = 1 monitoring = on, i.e. if communication fails, the outputs are deenergised (default settings) |
| P1 | Input filter P1 = 0 input filter on, pulse suppression ≤ 2 ms P1 = 1 input filter off (default settings) |
| P2 | Synchronous mode P2 = 0 synchronous mode on P2 = 1 synchronous mode off (default settings) |
| P3 | not used |
Ambient conditions
| Ambient temperature | -25 ... 60 °C (-13 ... 140 °F) |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity | 85 % , non-condensing |
| Climatic conditions | For indoor use only |
| Altitude | ≤ 2000 m above MSL |
| Shock and impact resistance | 15 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions, 1000 shocks |
| Vibration resistance | 0.35 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles |
| Pollution degree | 2 |
Mechanical specifications
| Degree of protection | IP20 Installation in an enclosure with a minimum protection class of IP54 required |
| Connection | Removable push-in terminalsrated connection capacity:rigid: 0.20 mm2 ... 1.5 mm2flexible (without wire end ferrule): 0.20 mm2 ... 2.5 mm2flexible (with wire end ferrule): 0.25 mm2 ... 1.5 mm2 |
| Material: Housing | PA 66-FR |
| Mass | 125 g |
| Dimensions: Height | 100 mm |
| Dimensions: Width | 18.9 mm |
| Dimensions: Length | 124 mm |
| Mounting | DIN mounting rail |
No matching specifications
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
VBA-4E4A-KE5-ZEJQ/R: frequently asked questions
When can VBA-4E4A-KE5-ZEJQ/R be shipped?
VBA-4E4A-KE5-ZEJQ/R is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up VBA-4E4A-KE5-ZEJQ/R in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for VBA-4E4A-KE5-ZEJQ/R and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VBA-4E4A-KE5-ZEJQ/R, subject to availability and destination.