Quick facts

AvailabilityConfirmed on request
CategoryModules
Lifecycleactive
Warranty12-month (new) · 3-month (used/refurbished)

Shipping & availability

When can VBA-4E4A-KE-ZE/R be shipped?

VBA-4E4A-KE-ZE/R is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up VBA-4E4A-KE-ZE/R in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for VBA-4E4A-KE-ZE/R and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VBA-4E4A-KE-ZE/R, subject to availability and destination.

AS-Interface sensor/actuator module. KE switch cabinet module, 4 inputs (PNP) and 4 relay outputs. Node type: A/B node. AS-Interface specification: V3.0. Required gateway specification: ≥ V3.0. Profile: S-7.A.7. IO code7ID codeAID1 code7ID2 code7: . IO code: 7. ID code: A. ID1 code: 7. ID2 code: 7. UL File Number: E106378. LED FAULT: Fault display; Red LEDred: Communication fault or address is 0red, flashing: Overload, internal input supply. LED INT: Internal input supply active; LED green. LED PWR: AS-Interface voltage; LED green. LED IN: switching state (input); 4 LED yellow. LED OUT: Switching state (output); 4 LED yellow. Auxiliary voltage (input): 12 ... 30 V DC PELV. Rated operating voltage: 26.5 ... 31.6 V from AS-Interface. Rated operating current: ≤ 35 mA (no sensors)/max. 210 mA. Surge protection: O1 ... O4: Over voltage category IIUEXT, Ue: Over voltage category III, safe isolated power supplies (PELV). Number/Type: 4 inputs for 2- or 3-wire sensors (PNP), DC. Supply: from AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT). Voltage: 21 ... 31 V DC (INT). Current loading capacity: ≤ 150 mA, overload- and short-circuit protected (INT). Input current: ≤ 8 mA (limited internally). Switching point: according to DIN EN 61131-2 (Type 2). 0 (unattenuated)≤ 2 mA1 (attenuated)≥ 4 mA: . 0 (unattenuated): ≤ 2 mA. 1 (attenuated): ≥ 4 mA. Signal delay: < 2 ms (input/AS-Interface). Number/Type: 4 relay outputs, normally open. Supply: none. Nominal load: . Per contact2 A / 30 V DC (acc. UL max. 24 V DC); 2 A / 253 V ACPer module8 A: . Per contact: 2 A / 30 V DC (acc. UL max. 24 V DC); 2 A / 253 V AC. Per module: 8 A. Control circuit: ≤ 8 mA per relay (from AS-Interface). Switching delay: < 10 ms (AS-Interface/contact). Usage category: DC-13 and AC-14. Switching: . Mechanical5 x 106Electrical0.2 x 106 (250 V AC, 2 A, cos φ = 0.4): . Mechanical: 5 x 106. Electrical: 0.2 x 106 (250 V AC, 2 A, cos φ = 0.4). Input/Output: safe isolation, rated insulation voltage 300 V AC. Input/AS-Interface: Switch position INT: None Switch position EXT: reinforced insulation, rated insulation voltage 66 V DC. Output/Output: basic insulation, rated insulation voltage 300 V AC. Output/AS-Interface: safe isolation, rated insulation voltage 300 V AC. Electromagnetic compatibility: . Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-4:2007 EN 61326-1:2006: . Directive 2014/30/EU: EN 62026-2:2013 EN 61000-6-4:2007 EN 61326-1:2006. Low voltage: . Directive 73/23/EECEN 60947-1:2007: . Directive 73/23/EEC: EN 60947-1:2007. Galvanic isolation: EN 60947-1:2007. Degree of protection: EN 60529:2000. Fieldbus standard: EN 62026-2:2013. Input: EN 61131-2:2004. Emitted interference: EN 61000-6-4:2007. AS-Interface: EN 62026-2:2013. Noise immunity: EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013. Ambient temperature: -25 ... 60 °C (-13 ... 140 °F). Storage temperature: -25 ... 85 °C (-13 ... 185 °F). Relative humidity: 85 % , noncondensing. Climatic conditions: For indoor use only. Altitude: ≤ 2000 m above MSL. Pollution degree: 2. Degree of protection: IP20. Connection: removable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2. Material: . HousingPA 66-FR: . Housing: PA 66-FR. Mass: 170 g. Dimensions: . Height99 mmWidth22.5 mmLength102 mm: . Height: 99 mm. Width: 22.5 mm. Length: 102 mm. Mounting: DIN mounting rail. Tightening torque of clamping screws: 0.5 Nm ... 0.6 Nm

Specifications

General specifications

Node typeA/B node
AS-Interface specificationV3.0
Required gateway specification≥ V3.0
ProfileS-7.A.7
IO code7ID codeAID1 code7ID2 code7 IO code
IO code7
ID codeA
ID1 code7
ID2 code7
UL File NumberE106378

Indicators/operating means

LED FAULTFault display; Red LEDred: Communication fault or address is 0red, flashing: Overload, internal input supply
LED INTInternal input supply active; LED green
LED PWRAS-Interface voltage; LED green
LED INswitching state (input); 4 LED yellow
LED OUTSwitching state (output); 4 LED yellow

Electrical specifications

Auxiliary voltage (input)12 ... 30 V DC PELV UEXT
Rated operating voltage26.5 ... 31.6 V from AS-Interface Ue
Rated operating current≤ 35 mA (no sensors)/max. 210 mA Ie
Surge protectionO1 ... O4: Over voltage category IIUEXT, Ue: Over voltage category III, safe isolated power supplies (PELV)

Input

Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC
Supplyfrom AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT)
Voltage21 ... 31 V DC (INT)
Current loading capacity≤ 150 mA, overload- and short-circuit protected (INT)
Input current≤ 8 mA (limited internally)
Switching pointaccording to DIN EN 61131-2 (Type 2)
0 (unattenuated)≤ 2 mA1 (attenuated)≥ 4 mA 0 (unattenuated)
0 (unattenuated)≤ 2 mA
1 (attenuated)≥ 4 mA
Signal delay< 2 ms (input/AS-Interface)

Output

Number/Type4 relay outputs, normally open
Supplynone
Nominal load
Per contact2 A / 30 V DC (acc. UL max. 24 V DC); 2 A / 253 V ACPer module8 A Per contact
Per contact2 A / 30 V DC (acc. UL max. 24 V DC); 2 A / 253 V AC
Per module8 A
Control circuit≤ 8 mA per relay (from AS-Interface)
Switching delay< 10 ms (AS-Interface/contact)
Usage categoryDC-13 and AC-14
Switching
Mechanical5 x 106Electrical0.2 x 106 (250 V AC, 2 A, cos φ = 0.4) Mechanical
Mechanical5 x 106
Electrical0.2 x 106 (250 V AC, 2 A, cos φ = 0.4)

Galvanic isolation

Input/Outputsafe isolation, rated insulation voltage 300 V AC
Input/AS-InterfaceSwitch position INT: None Switch position EXT: reinforced insulation, rated insulation voltage 66 V DC
Output/Outputbasic insulation, rated insulation voltage 300 V AC
Output/AS-Interfacesafe isolation, rated insulation voltage 300 V AC

Directive conformity

Electromagnetic compatibility
Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-4:2007 EN 61326-1:2006 Directive 2014/30/EU
Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-4:2007 EN 61326-1:2006
Low voltage
Directive 73/23/EECEN 60947-1:2007 Directive 73/23/EEC
Directive 73/23/EECEN 60947-1:2007

Standard conformity

Galvanic isolationEN 60947-1:2007
Degree of protectionEN 60529:2000
Fieldbus standardEN 62026-2:2013
InputEN 61131-2:2004
Emitted interferenceEN 61000-6-4:2007
AS-InterfaceEN 62026-2:2013
Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013

Ambient conditions

Ambient temperature-25 ... 60 °C (-13 ... 140 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Relative humidity85 % , noncondensing
Climatic conditionsFor indoor use only
Altitude≤ 2000 m above MSL
Pollution degree2

Mechanical specifications

Degree of protectionIP20
Connectionremovable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2
Material
HousingPA 66-FR Housing
HousingPA 66-FR
Mass170 g
Dimensions
Height99 mmWidth22.5 mmLength102 mm Height
Height99 mm
Width22.5 mm
Length102 mm
MountingDIN mounting rail
Tightening torque of clamping screws0.5 Nm ... 0.6 Nm
12-month warrantyon all new stock
3-month warrantyon used & refurbished parts
30-day returnsno restocking fee on unused parts
Global shippingFast, tracked delivery worldwide

More Pepperl Fuchs parts

Pepperl + Fuchs KFD2-GUT-EX1.D New open boxNewPepperl + Fuchs KFD2-GUT-EX1.D New open box
MPN: KFD2-GUT-EX1.D · Pepperl Fuchs
€380.54
View details
50025-c21.1/2 - pepperl+fuchsUsed50025-c21.1/2 - pepperl+fuchs
MPN: 50025-c21.1/2 · Pepperl Fuchs
€10.60
View details
Pepperl Fuchs V19-W-BK15M-PUR-U-V19-GAvailable on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G
MPN: V19-W-BK15M-PUR-U-V19-G · Pepperl Fuchs
Price on request
Request a quote
Pepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-GAvailable on requestPepperl Fuchs V1SD-G-GN65M-PUR-E1S-V45-G
MPN: V1SD-G-GN65M-PUR-E1S-V45-G · Pepperl Fuchs
Price on request
Request a quote