What is the Pepperl Fuchs VBA-4E4A-KE-ZE/R?

Housing with removable, mechanical and color coded terminals

Communication monitoring

Inputs for 2- and 3-wire sensors

Isolated relay output

Addressing jack

Selectable supply to the sensors: External or from the module

Function display for bus, internal sensor supply, inputs, and outputs

KE switch cabinet module, 4 inputs (PNP) and 4 relay outputs

Specifications

General specifications

Order code (Pepperl+Fuchs part number)200913
Node typeA/B node
AS-Interface specificationV3.0
Required gateway specification≥ V3.0
ProfileS-7.A.7
IO code7
ID codeA
ID1 code7
ID2 code7
UL File NumberE106378
LifecycleActive (current Pepperl+Fuchs product)

Indicators/operating means

LED FAULTFault display; Red LED red: Communication fault or address is 0 red, flashing: Overload, internal input supply
LED INTInternal input supply active; LED green
LED PWRAS-Interface voltage; LED green
LED INswitching state (input); 4 LED yellow
LED OUTSwitching state (output); 4 LED yellow

Electrical specifications

Auxiliary voltage (input)12 ... 30 V DC PELV UEXT
Rated operating voltage26.5 ... 31.6 V from AS-Interface Ue
Rated operating current≤ 35 mA (no sensors)/max. 210 mA Ie
Surge protectionO1 ... O4: Over voltage category IIUEXT, Ue: Over voltage category III, safe isolated power supplies (PELV)

Input

Number/Type4 inputs for 2- or 3-wire sensors (PNP), DC
Supplyfrom AS-Interface (switch position INT, default settings) or external UEXT (switch position EXT)
Voltage21 ... 31 V DC (INT)
Current loading capacity≤ 150 mA, overload- and short-circuit protected (INT)
Input current≤ 8 mA (limited internally)
Switching pointaccording to DIN EN 61131-2 (Type 2)
0 (unattenuated)≤ 2 mA
1 (attenuated)≥ 4 mA
Signal delay< 2 ms (input/AS-Interface)

Output

Number/Type4 relay outputs, normally open
Supplynone
Nominal load: Per contact2 A / 30 V DC (acc. UL max. 24 V DC); 2 A / 253 V AC
Nominal load: Per module8 A
Control circuit≤ 8 mA per relay (from AS-Interface)
Switching delay< 10 ms (AS-Interface/contact)
Usage categoryDC-13 and AC-14
Switching: Mechanical5 x 106
Switching: Electrical0.2 x 106 (250 V AC, 2 A, cos φ = 0.4)
Overload protectionfuse unit 2 A required in the load current circuit

Galvanic isolation

Input/Outputsafe isolation, rated insulation voltage 300 V AC
Input/AS-InterfaceSwitch position INT: None Switch position EXT: reinforced insulation, rated insulation voltage 66 V DC
Output/Outputbasic insulation, rated insulation voltage 300 V AC
Output/AS-Interfacesafe isolation, rated insulation voltage 300 V AC

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 62026-2:2013 EN 61000-6-4:2007 EN 61326-1:2006
Low voltage: Directive 73/23/EECEN 60947-1:2007

Standard conformity

Galvanic isolationEN 60947-1:2007
Degree of protectionEN 60529:2000
Fieldbus standardEN 62026-2:2013
InputEN 61131-2:2004
Emitted interferenceEN 61000-6-4:2007
AS-InterfaceEN 62026-2:2013
Noise immunityEN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013

Ambient conditions

Ambient temperature-25 ... 60 °C (-13 ... 140 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)
Relative humidity85 % , non-condensing
Climatic conditionsFor indoor use only
Altitude≤ 2000 m above MSL
Pollution degree2

Mechanical specifications

Degree of protectionIP20
Connectionremovable terminalsrated connection capacity:rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2for multiple-wire connection with two wires of equal cross-section:flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2
Material: HousingPA 66-FR
Mass170 g
Dimensions: Height99 mm
Dimensions: Width22.5 mm
Dimensions: Length102 mm
MountingDIN mounting rail
Tightening torque of clamping screws0.5 Nm ... 0.6 Nm

Downloads & documentation

Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.

Data sheets & manuals

CAD & dimension drawings

Certificates (2)

VBA-4E4A-KE-ZE/R: frequently asked questions

When can VBA-4E4A-KE-ZE/R be shipped?

VBA-4E4A-KE-ZE/R is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up VBA-4E4A-KE-ZE/R in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for VBA-4E4A-KE-ZE/R and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VBA-4E4A-KE-ZE/R, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs VBA-4E4A-KE-ZE/RPrice and lead time confirmed within 1 business day
Request a Quote