Pepperl Fuchs VAA-2E1A-G10-SAJ/EA2J-1M
AS-Interface safety module
- MPN
- VAA-2E1A-G10-SAJ/EA2J-1M
- Category
- Safety at Work
Request a Quote
- 1We check stock, condition and lead time
- 2You get a written quote by email
- 3Approve it and we ship — in-stock parts within 1 business day
- 12-month warranty (new) · 3-month (used/refurbished)
- 30-day returns, no restocking fee on unused parts
- 100% positive eBay feedback
- Ships via
What is the Pepperl Fuchs VAA-2E1A-G10-SAJ/EA2J-1M?
Connection of contact safety switches, e.g. EMERGENCY STOP button
Applications up to PL e
Modular safety solution
Ultra-compact enclosure
Degree of protection IP67
Applications up to Cat. 4, PL e/SIL 3
G10 safety module, 2 safety-related inputs and 1 standard electronic output
Specifications
General specifications
| Order code (Pepperl+Fuchs part number) | 229182 |
| Node type | Safety-Slave |
| AS-Interface specification | V3.0 |
| Required gateway specification | ≥ V2.1 |
| UL File Number | E223772 "For use in NFPA 79 Applications only" |
| Lifecycle | Active (current Pepperl+Fuchs product) |
Functional safety related parameters
| Safety Integrity Level (SIL) | SIL 3 |
| Performance level (PL) | PL e |
| Category | Cat. 4 |
| MTTFd | no significant contribution to MTTFd of the overall system |
| Mission Time (TM) | 20 a |
Indicators/operating means
| LED FLT | error display; LED red red: communication error or address is 0 |
| LED AS-i | AS-Interface voltage; green LED green: voltage OK flashing green: address 0 |
| LED IN | switching state (input); 2 LED yellow |
| LED OUT | Switching state (output); LED yellow |
Electrical specifications
| Rated operating voltage | 26.5 ... 31.6 V from AS-Interface (PELV) Ue |
| Rated operating current | ≤ 90 mA Ie |
| Protection class | III |
| Surge protection | overvoltage category III |
| Rated insulation voltage | 32 V |
| Pulse withstand voltage | 0.8 kV |
Input
| Number/Type | 2 safety-related inputs for mechanical contacts, crossed-circuit monitored:2 single-channel contacts: up to category 2/PL c to ISO 13849-1 or1 2-channel contact: up to category 4/PL e to ISO 13849-1 |
| Supply | from AS-Interface |
| Voltage | 20 ... 30 V DC pulsed |
| Current | input current limited ≤ 15 mA,short-circuit protected |
Output
| Number/Type | 1 conventional electronic output, PNP |
| Supply | from AS-Interface |
| Voltage | (UASI - 7.0 V) ≤ UOUT ≤ UASI |
| Current | 50 mA , short-circuit/overload protected |
Directive conformity
| Electromagnetic compatibility: Directive 2014/30/EU | EN 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007 |
Standard conformity
| Degree of protection | EN 60529:2000 |
| Fieldbus standard | EN 62026-2:2013 |
| Electrical safety | IEC 61140:2009 |
| Emitted interference | EN 61000-6-4:2007 |
| AS-Interface | EN 62026-2:2013 |
| Noise immunity | IEC 62026-2:2013 EN IEC 62061:2021 EN 61000-6-2:2005 |
| Functional safety | EN ISO 13849-1:2023 EN IEC 62061:2021 |
Programming instructions
| Profile | S-7.B |
| IO code | 7 |
| ID code | B |
| ID1 code | F |
| ID2 code | 0 |
| Data bits (function via AS-Interface) | InputOutput |
| D0 | dyn. safety code 1 OUT 1 |
| D1 | dyn. safety code 1 - |
| D2 | dyn. safety code 2 - |
| D3 | dyn. safety code 2 - |
| Parameter bits (programmable via AS-i) | function |
| P0 | communication monitoring P0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition |
| P1 | not used |
| P2 | not used |
| P3 | not used |
Approvals and certificates
| UL approval | cULus Listed, Type 1 enclosure |
Ambient conditions
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) |
| Storage temperature | -25 ... 80 °C (-13 ... 176 °F) |
| Relative humidity | < 95 % |
| Altitude | ≤ 2000 m above MSL |
| Shock and impact resistance | 30 g, 11 ms in 6 spatial directions 3 shocks 10 g, 16 ms in 6 spatial directions 1000 shocks |
| Vibration resistance | 0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles |
| Pollution degree | 3 |
Mechanical specifications
| Degree of protection | IP67This protection class is achieved by using the AS-Interface flat cable VAZ-FK-S-YE |
| Connection | AS-Interface: AS-Interface flat cable Inputs/outputs: open conductor ends |
| Material: Contacts | open conductor ends with connector sleeves |
| Material: Housing | PBT |
| Material: Cable | PUR |
| Material: Mounting screw | Stainless steel 1.4305 / AISI 303 |
| Cable: Sheath diameter | ∅4.8 mm |
| Cable: Bending radius | > 8 x cable diameter, fixed installation > 10 x cable diameter, movable installation not appropriate for conveyor chains |
| Cable: Color | black |
| Cable: Cores | 6 x 0.25 mm2 |
| Cable: Length | 1 m L |
| Mass | 200 g |
| Tightening torque, fastening screws | 1.65 Nm |
| Dimensions: Height | 21.5 mm |
| Dimensions: Width | 27.7 mm |
| Dimensions: Length | 40.5 mm |
No matching specifications
Downloads & documentation
Official documents from Pepperl Fuchs, downloaded directly from the manufacturer.
Data sheets & manuals
CAD & dimension drawings
VAA-2E1A-G10-SAJ/EA2J-1M: frequently asked questions
When can VAA-2E1A-G10-SAJ/EA2J-1M be shipped?
VAA-2E1A-G10-SAJ/EA2J-1M is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up VAA-2E1A-G10-SAJ/EA2J-1M in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for VAA-2E1A-G10-SAJ/EA2J-1M and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for VAA-2E1A-G10-SAJ/EA2J-1M, subject to availability and destination.
More Pepperl Fuchs parts