Pepperl Fuchs V3-4A-E2-V19
Request a Quote
Quick facts
| Availability | Confirmed on request |
| Category | Passive Splitters |
| Lifecycle | active |
| Warranty | 12-month (new) · 3-month (used/refurbished) |
Shipping & availability
When can V3-4A-E2-V19 be shipped?
V3-4A-E2-V19 is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.
Can I pick up V3-4A-E2-V19 in person?
Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.
Is express delivery available?
Yes — mention it when you request a quote for V3-4A-E2-V19 and we'll include express shipping options in our reply.
My factory is down and I need this urgently — can you help?
For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for V3-4A-E2-V19, subject to availability and destination.
Splitter box M8. Splitter box 4 x M8 single allocation, with 8-pole M12 plug. Connector 1: . ConnectionsocketConstruction type4x M8Lockingscrew connectionNumber of pins3CodingA-coded: . Connection: socket. Construction type: 4x M8. Locking: screw connection. Number of pins: 3. Coding: A-coded. Connector 2: . ConnectionplugConstruction typeM12Lockingscrew connectionNumber of pins8CodingA-coded: . Connection: plug. Construction type: M12. Locking: screw connection. Number of pins: 8. Coding: A-coded. UL File Number: E223772. LED green: supply voltage each module. LED yellow: I/O status indication. Operating voltage: 24 V DC, max. 30 V DC. Operating current: ≤ 5 mA per channel indication element. Current loading capacity: ≤ 2 A per channel,≤ 2 A per plug-in station,≤ 2 A total current per splitter box. Degree of protection: EN 60529. Plug connection: connector M8 x 1 : IEC 61076-2-104 connector M12 x 1 : IEC 61076-2-101. Flammability: UL 94. Ambient temperature: -25 ... 80 °C (-13 ... 176 °F). Connector 1: . Tightening torque0.2 NmMating cyclesmin. 100: . Tightening torque: 0.2 Nm. Mating cycles: min. 100. Connector 2: . Tightening torque0.4 NmMating cyclesmin. 100: . Tightening torque: 0.4 Nm. Mating cycles: min. 100. Degree of protection: IP67. Mass: 74.87 g. Plug connector: . Screw connectionCu alloy , nickel-platedBodyPBT, blackSealFKMContact surfaceNi/AuFlammabilityV-0: . Screw connection: Cu alloy , nickel-plated. Body: PBT, black. Seal: FKM. Contact surface: Ni/Au. Flammability: V-0. Note: During installation of cables respect the maximum allowed bending radius. Excessive bending forces endanger the degree of protection.Secure the connector from mechanical forces, for example by means of cable ties.Close unused plug-in slots prior to commissioning. Respective sealing elements you will find under "accessories".
Specifications
General specifications
| Connector 1 | |
| ConnectionsocketConstruction type4x M8Lockingscrew connectionNumber of pins3CodingA-coded | Connection |
| Connection | socket |
| Construction type | 4x M8 |
| Locking | screw connection |
| Number of pins | 3 |
| Coding | A-coded |
| Connector 2 | |
| ConnectionplugConstruction typeM12Lockingscrew connectionNumber of pins8CodingA-coded | Connection |
| Connection | plug |
| Construction type | M12 |
| Locking | screw connection |
| Number of pins | 8 |
| Coding | A-coded |
| UL File Number | E223772 |
Indicators/operating means
| LED green | supply voltage each module |
| LED yellow | I/O status indication |
Electrical specifications
| Operating voltage | 24 V DC, max. 30 V DC UB |
| Operating current | ≤ 5 mA per channel indication element IB |
| Current loading capacity | ≤ 2 A per channel,≤ 2 A per plug-in station,≤ 2 A total current per splitter box |
Conformity
| Degree of protection | EN 60529 |
| Plug connection | connector M8 x 1 : IEC 61076-2-104 connector M12 x 1 : IEC 61076-2-101 |
| Flammability | UL 94 |
Ambient conditions
| Ambient temperature | -25 ... 80 °C (-13 ... 176 °F) |
Mechanical specifications
| Connector 1 | |
| Tightening torque0.2 NmMating cyclesmin. 100 | Tightening torque |
| Tightening torque | 0.2 Nm |
| Mating cycles | min. 100 |
| Connector 2 | |
| Tightening torque0.4 NmMating cyclesmin. 100 | Tightening torque |
| Tightening torque | 0.4 Nm |
| Mating cycles | min. 100 |
| Degree of protection | IP67 |
| Mass | 74.87 g |
Material
| Plug connector | |
| Screw connectionCu alloy , nickel-platedBodyPBT, blackSealFKMContact surfaceNi/AuFlammabilityV-0 | Screw connection |
| Screw connection | Cu alloy , nickel-plated |
| Body | PBT, black |
| Seal | FKM |
| Contact surface | Ni/Au |
| Flammability | V-0 |
General information
| Note | During installation of cables respect the maximum allowed bending radius. Excessive bending forces endanger the degree of protection.Secure the connector from mechanical forces, for example by means of cable ties.Close unused plug-in slots prior to commissioning. Respective sealing elements you will find under "accessories". |
More Pepperl Fuchs parts
NewPepperl + Fuchs KFD2-GUT-EX1.D New open box
Available on requestPepperl Fuchs V19-W-BK15M-PUR-U-V19-G