What is the Pepperl Fuchs RD0-TI-Ex8.FF.*?

For 8 temperature or analog sensors

Installation in Zone 1/Div. 1, intrinsically safe

Sensors in Zone 0/Div. 1

Connection to fieldbus acc. to FISCO or Entity

For FOUNDATION Fieldbus H1

PCS integration via device description and function blocks

Concentrator method for simplified configuration

Monitors sensor condition

For T/C, RTD 2-, 3-, 4-wire, voltage and resistance

Cold junction compensation

Removable terminals

Temperature multi-input, electronic component for control cabinet installation, For 8 temperature or analog sensors, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1, IECEx approval, Dust protection, International, Europe, USA, Canada

Specifications

General specifications

Order code (Pepperl+Fuchs part number)T158061
Design / MountingCabinet installation
Installation in hazardous areaZone 1 / Div. 1
LifecycleActive (current Pepperl+Fuchs product)

Fieldbus connection

Fieldbus typeFOUNDATION Fieldbus
Physical layer profileprofile type 511 (FISCO), profile type 111 (Entity)
ITK version6.2.0 (DEV_REV 02)
Implementationresource block 1x RS function block 8x AI, 1x MAI transducer block 8x sensor TB, 1x concentrator TB
Execution timeAI, MAI 40 ms max.
Macro cycletypical for one device 8xAI or 1xMAI max. 500 ms
Firmware updatevia separate plug connection
FDE (Fault Disconnect Equipment)6.7 mA
Polaritynot polarity sensitive
Rated voltage9 ... 32 V UN
Rated currentmax. 23 mA IN

Indicators/operating means

LED PWRgreen: on, bus voltage existent
LED COM ERRred, continuous lightning: hardware error; red, flashing: no bus activities or bus fault; off: no error
LED CHANNEL ERRORred: 2 Hz flashing: lead breakage, overrange; off: no error

Input

Number8
Sensor typessee table 1
Groundinggrounding of thermoelements possible
Error detectionlead breakage, wiring error, hardware device error
Common mode voltageInput to Input 600 Vpeak

Transfer characteristics

Deviation: Cold junction compensation± 0.5 °C (32.9 °F)
Deviation: Resolution/accuracysee table 2
Deviation: Influence of ambient temperaturesee table 3
Deviation: LinearizationT/C input 0.1°C RTD input 0.03°C
Internal measurement cyclefor all sensor types max. 1 s

Galvanic isolation

Fieldbus/inputssafe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013

Standard conformity

Galvanic isolationEN 60079-11
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC 60529
Fieldbus standardIEC 61158-2
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6

Ambient conditions

Ambient temperature-40 ... 70 °C (-40 ... 158 °F) hazardous area -40 ... 85 °C (-40 ... 185 °F) safe area
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity≤ 95 % non-condensing
Shock resistance15 g , 11 ms
Vibration resistance5 g , 10 ... 150 Hz
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3

Mechanical specifications

Connection typeplug-in terminals , spring terminal and screw terminal
Core cross section: Busup to 2.5 mm2
Core cross section: Inputsup to 2.5 mm2
Housing materialPolycarbonate
Degree of protectionIP20
Mass360 g
MountingDIN rail mounting

Data for application in connection with hazardous areas

EU-type examination certificatePTB 03 ATEX 2237
MarkingII 2 (1) G Ex ia [ia Ga] IIC T4 Gb , [exsign] II (1) G [Ex ia Ga] IIC , [exsign] II (1) D [Ex ia Da] IIIC , [exsign] II 3 G Ex ic IIC T4 Gc
BusFISCO see EC-Type Examination Certificate
Inputssee EC-Type Examination Certificate
CertificatePTB 03 ATEX 2238 X
MarkingII 3 G Ex nA IIC T4 Gc
Galvanic isolation: Bussee Statement of Conformity
Galvanic isolation: Inputsee EC-Type Examination Certificate
Directive conformity: Directive 2014/34/EUEN IEC 60079-0:2018+AC:2020 , EN 60079-11:2012 , EN 60079-15:2010

International approvals

FM approval: FM certificateFM18US0054X , FM18CA0027X
FM approval: Control drawing16-473FM-12A
IECEx approval: IECEx certificateIECEx PTB 05.0001 IECEx PTB 05.0002X
IECEx approval: IECEx markingEx ia [ia Ga] IIC T4 Gb [Ex ia Ga] IIC [Ex ia Da] IIIC Ex ic IIC T4 Gc Ex nA IIC T4 Gc

General information

Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

RD0-TI-Ex8.FF.*: frequently asked questions

When can RD0-TI-Ex8.FF.* be shipped?

RD0-TI-Ex8.FF.* is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up RD0-TI-Ex8.FF.* in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for RD0-TI-Ex8.FF.* and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for RD0-TI-Ex8.FF.*, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs RD82 SW4 – Reflector
Pepperl Fuchs
RD82 SW4

Reflector

Pepperl Fuchs RD0-TI-Ex8.FF.*Price and lead time confirmed within 1 business day
Request a Quote