Pepperl Fuchs R8D0-MIO-Ex12.FF*

Multi-Input/Output

MPN
R8D0-MIO-Ex12.FF*
Price and lead time confirmed within 1 business day
Request a Quote
  1. 1We check stock, condition and lead time
  2. 2You get a written quote by email
  3. 3Approve it and we ship — in-stock parts within 1 business day

A real person replies, typically within 1 business day — see our privacy policy.

  • 12-month warranty (new) · 3-month (used/refurbished)
  • 30-day returns, no restocking fee on unused parts
  • 100% positive eBay feedback
  • Ships via

Have spare Pepperl Fuchs parts? We buy surplus →

What is the Pepperl Fuchs R8D0-MIO-Ex12.FF*?

For discrete inputs and outputs

Installation in Zone 1/Div. 1, intrinsically safe

Sensors in Zone 0/Div. 1

Connection to fieldbus acc. to FISCO or Entity

For FOUNDATION Fieldbus H1

PCS integration via device description and function blocks

Monitors sensor condition

Removable terminals

Power, Com, Diagnostics, and Error LEDs

Test points for easy troubleshooting

Multi-input/output for digital signals, module for DIN rail mounting, For discrete inputs and outputs, Installation in Zone 1/Div. 1, intrinsically safe, Sensors in Zone 0/Div. 1, Connection to fieldbus acc. to FISCO or Entity, For FOUNDATION Fieldbus H1, IECEx approval, Dust protection, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area, Zone 2 - high-power trunk, Zone 1 - high-power trunk, Division 2 - high-power trunk, Division 1 - high-power trunk

Specifications

General specifications

Order code (Pepperl+Fuchs part number)T178361
Design / MountingCabinet installation
Installation in hazardous areaZone 1 / Div. 1
LifecycleActive (current Pepperl+Fuchs product)

Fieldbus connection

Fieldbus typeFOUNDATION Fieldbus
Physical layer profileprofile type 511 (FISCO), profile type 111 (Entity)
ITK version6.1.1
Implementationresource block 1x RS function block 4x DO, 12x DI, 1x AI, 2x MDI, 1x MDO transducer block 4x TB
FDE (Fault Disconnect Equipment)6.7 mA
Polaritynot polarity sensitive
Rated voltage9 ... 32 V UN
Rated currentmax. 23 mA IN

Indicators/operating means

LED PWRgreen: on, bus voltage existent
LED COM ERRred, continuous lightning: hardware error; red, flashing: no bus activities or bus fault; off: no error
LED CHANNEL ERRORred, flashing: lead breakage/short circuit; off: no error
DIP switchAddress setting , write protection , simulation

Analog input

Number of inputs1
Input typeFrequency input / Counter Input , channel 1
Accuracy0.5 % of the measured value
Switching frequencymin. 0.1 Hz max. 5 kHz
Pulse durationmin. 80 µs
Supply voltage5 V
Supply current5 mA
Line fault detectionlead breakage , short circuit (not in counter mode)

Digital input

Number of inputs12
Input typeSensor input , channels 1, 4, 7, 10 multiplexed , cycle adjustable
Supply voltage6.6 V
Supply current5 mA
Line fault detectionlead breakage , short circuit
Input typeSensor input , channels 2, 3, 5, 6, 8, 9, 11, 12 multiplexed , cycle fixed
Supply voltage5 V
Supply current5 mA
Time delay before availability2 ms
Line fault detectionlead breakage , short circuit

Digital output

Number of outputs4
Output typeLow power valve , channels 1, 4, 7, 10
Supply voltage6.6 V
Supply current1.5 mA
Line fault detectionlead breakage , short circuit

Galvanic isolation

Foundation Fieldbus/Field circuitsafe galvanic isolation acc. to EN 60079-11, voltage peak value 375 V

Directive conformity

Electromagnetic compatibility: Directive 2014/30/EUEN 61326-1:2013
Low voltage: Directive 2014/35/EUEN 61010-1:2010

Standard conformity

Galvanic isolationEN 60079-11
Electromagnetic compatibilityNE 21:2011
Degree of protectionIEC/EN 60529
Fieldbus standardIEC 61158-2
Shock resistanceEN 60068-2-27
Vibration resistanceEN 60068-2-6

Ambient conditions

Ambient temperature-50 ... 75 °C (-58 ... 167 °F) hazardous area -50 ... 85 °C (-58 ... 185 °F) safe area
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Relative humidity≤ 95 % non-condensing
Shock resistance15 g , 11 ms
Vibration resistance5 g , 10 ... 150 Hz
Pollution degree2
Corrosion resistanceacc. to ISA-S71.04-1985, severity level G3

Mechanical specifications

Connection typeplug-in terminals , spring terminal and screw terminal
Core cross section: Busup to 2.5 mm2
Core cross section: Inputsup to 2.5 mm2
Housing materialPolycarbonate
Degree of protectionIP20
Massapprox. 290 g
MountingDIN rail mounting

Data for application in connection with hazardous areas

EU-type examination certificateBVS 16 ATEX E 075 X
MarkingII 2 (1) G Ex ib [ia Ga] IIC T4 Gb , [exsign] II 3 (1) G Ex ic [ia Ga] IIC T4 Gc , [exsign] II 3 (1) G Ex ec [ia Ga] IIC T4 Gc , [exsign] I (M1) [Ex ia Ma] I , [exsign] II (1) D [Ex ia Da] IIIC
Field-side: Voltage Uo9 V
Field-side: Current Io43 mA
Field-side: Power Po96 mW
FOUNDATION Fieldbus: Maximum safe voltage Um253 V
FOUNDATION Fieldbus: Voltage Ui24 V
FOUNDATION Fieldbus: Current Ii380 mA
FOUNDATION Fieldbus: Power Pi5.32 W
Directive conformity: Directive 2014/34/EUEN 60079-0:2012 , EN 60079-11:2012 , EN 60079-7:2015

International approvals

FM approvalpending
IECEx approvalIECEx BVS 16.0051X
Approved forEx ib [ia Ga] IIC T4 Gb ,Ex ic [ia Ga] IIC T4 Gc ,Ex ec [ia Ga] IIC T4 Gc ,[Ex ia Da] IIIC , [Ex ia Ma] I

Certificates and approvals

Marine approvalpending

General information

Supplementary informationEC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

R8D0-MIO-Ex12.FF*: frequently asked questions

When can R8D0-MIO-Ex12.FF* be shipped?

R8D0-MIO-Ex12.FF* is sourced on request — request a quote and we'll confirm the exact availability and shipping timeline for this specific unit.

Can I pick up R8D0-MIO-Ex12.FF* in person?

Local pickup from our Groningen, Netherlands warehouse may be possible — contact us before ordering to check availability and arrange a collection time.

Is express delivery available?

Yes — mention it when you request a quote for R8D0-MIO-Ex12.FF* and we'll include express shipping options in our reply.

My factory is down and I need this urgently — can you help?

For a critical breakdown, contact us directly at +31 (0)50-7110348 or sales@partnerplc.com — we can look into same-day courier or dedicated taxi/hotshot delivery for R8D0-MIO-Ex12.FF*, subject to availability and destination.

More Pepperl Fuchs parts

Pepperl Fuchs R30/60 – Reflector
Pepperl Fuchs
R30/60

Reflector

Pepperl Fuchs R4D0-FB-IA* – Fieldbus Barrier
Pepperl Fuchs
R4D0-FB-IA*

Fieldbus Barrier

Pepperl Fuchs R85/85 – Reflector
Pepperl Fuchs
R85/85

Reflector

Pepperl Fuchs RaCon-D BK – Radar motion sensor
Pepperl Fuchs
RaCon-D BK

Radar motion sensor

Pepperl Fuchs R8D0-MIO-Ex12.FF*Price and lead time confirmed within 1 business day